Get Quote
Home > Products > By type > Axial Fans > GF60252B2-10000-AEP | SUNON 24V 5W 60x60x25mm 62m3/h DC Axial Fan for Data Center Cooling

GF60252B2-10000-AEP SUNON Axial Fan

Brand :
SUNON
Model:
GF60252B2-10000-AEP | SUNON 24V 5W 60x60x25mm 62m3/h DC Axial Fan for Data Center Cooling
Type:
Axial Fans
Industry:
Data Center Cooling
Description:

Within servers and data-center electronics, SUNON GF60252B2-10000-AEP serves as a 60 × 60 × 25 mm DC axial fan operating at 24 VDC. 196.8 Pa maximum pressure is the standout documented duty-point value. Treat the duty-point values as a primary input to cooling-margin review. Check the full suffix before confirming connector details.

Datasheet:
GF60252B2-10000-AEP | SUNON 24V 5W 60x60x25mm 62m3/h DC Axial Fan for Data Center Cooling Datasheet (Pdf)

Product Features

Rated Voltage(V)24
Size(mm)60x60x25mm
Max.Air Flow(m³/h)62
Max.Pressure(Pa)196.8
Input Power(W)5
Speed(rpm)9000
Noise(db)47.2

Product Features

Reliable Fan Cooling

For server and data-center equipment, SUNON GF60252B2-10000-AEP serves as a DC brushless axial fan. The fan supports temperature control in equipment that runs through sustained or repeated duty cycles.

The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market. The enclosure should direct air across the heat source because bypass flow can reduce cooling even when the fan runs normally.

System designers selecting GF60252B2-10000-AEP should account for filter loading, then schedule system-resistance review before design lock. This approach links equipment cooling needs with practical procurement and service decisions. Include filters, vents and grilles when checking available airflow.

Application Industry

Frequently Asked Questions

How can GF60252B2-10000-AEP affect operating cost?

Compare its listed 5 W input with the required airflow and run time. Total savings depend on the complete system duty point.

What noise data are available for GF60252B2-10000-AEP?

The worksheet lists 47.2 dB. Installation distance, airflow resistance, and enclosure acoustics can change the measured result.

What should be checked if GF60252B2-10000-AEP stops?

Verify supply, wiring, obstructions, impeller movement, and protection status. Use the model datasheet before replacement or repair.

Does GF60252B2-10000-AEP have a documented pressure rating?

Yes. The worksheet lists up to 196.8 Pa; compare it with the system curve.

Which performance figures define GF60252B2-10000-AEP?

Use the listed voltage, size, 62 m³/h airflow, 9000 rpm, and 5 W input for preliminary comparison.

What equipment can use GF60252B2-10000-AEP?

It is listed for servers and data-center electronics. Check dimensions, airflow, pressure, and the installation environment against the actual equipment.