The GF60252B3-10000-AEP is SUNON's 24 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 104.6 Pa maximum pressure is the standout documented duty-point value. The recorded model record should guide cooling-margin review. Check the full suffix before confirming connector details.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 60x60x25mm |
| Max.Air Flow(m³/h) | 45.7 |
| Max.Pressure(Pa) | 104.6 |
| Input Power(W) | 2.76 |
| Speed(rpm) | 6450 |
| Noise(db) | 38 |
SUNON GF60252B3-10000-AEP supports server and data-center equipment with DC brushless axial fan airflow. It is intended for installations where predictable air exchange is central to equipment stability.
The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market.
The final GF60252B3-10000-AEP selection should consider connector reach as part of the installation layout. Finishing system-resistance review before design lock helps reduce integration uncertainty and supports reliable equipment cooling. Include filters, vents and grilles when checking available airflow. The final assembly should be tested under its expected thermal load.
SUNON GF60252B3-10000-AEP serves server platforms. Airflow around processors, memory and power components helps address sustained computing loads. The fan gives OEM equipment a defined air route and supports stable server operation. It supports reliable equipment cooling.
SUNON GF60252B3-10000-AEP serves storage equipment. Airflow around drives, controllers and power assemblies helps address continuous data workloads. The fan gives OEM equipment a defined air route and supports reliable storage availability. It supports reliable equipment cooling.
SUNON GF60252B3-10000-AEP serves edge-computing systems. Airflow around compact processing and communication modules helps address high heat density. The fan gives OEM equipment a defined air route and supports consistent thermal control. It supports reliable equipment cooling.
SUNON GF60252B3-10000-AEP serves data-center equipment. Airflow around critical computing assemblies helps address round-the-clock heat generation. The fan gives OEM equipment a defined air route and supports infrastructure availability. It supports reliable equipment cooling.
The worksheet lists 38 dB. Installation distance, airflow resistance, and enclosure acoustics can change the measured result.
The worksheet lists up to 45.7 m³/h. Verify the operating point against system resistance.
Yes. The worksheet lists up to 104.6 Pa; compare it with the system curve.
Review its 60 × 60 × 25 mm size, 45.7 m³/h airflow, 104.6 Pa pressure, system resistance, and available mounting space.
Assess reliability from the exact bearing, temperature, protection, and life data. The supplied series note alone does not confirm every suffix-specific option.
Confirm any missing bearing, connector, control, IP rating, life, certification, and performance-curve details for the complete part number.

The GF40282B3-10000-AEP is SUNON's 24 VDC, 40 × 40 × 28 mm DC axial fan option for servers and data-center electronics. Its 500 rpm rating defines a lower-speed operating point. Review its operating point during cooling-margin review. Check the full suffix before confirming connector details.
Read More
Within servers and data-center electronics, SUNON GF40282B2-10000-AEP serves as a 40 × 40 × 28 mm DC axial fan operating at 24 VDC. 276.5 Pa maximum pressure is the standout documented duty-point value. The recorded electrical load should guide cooling-margin review. Check the full suffix before confirming connector details.
Read More
SUNON GF40282B1-10000-AEP combines a 40 × 40 × 28 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. 343.7 Pa maximum pressure is the standout documented duty-point value. Treat the technical profile as a primary input to cabinet ventilation planning. Verify bearing and signal options in the exact datasheet.
Read More
Within servers and data-center electronics, SUNON GF40282B3-10000-SDP serves as a 40 × 40 × 28 mm DC axial fan operating at 24 VDC. 10500 W input is the defining electrical load in the supplied data. For cooling-margin review, start with the supplied frame geometry. Check the full suffix before confirming connector details.
Read More
GF40282B3-10000-QDP addresses servers and data-center electronics through a 24 VDC DC axial fan platform measuring 40 × 40 × 28 mm. 10500 W input is the defining electrical load in the supplied data. Use the documented cooling output when planning cooling-margin review. Check the full suffix before confirming connector details.
Read More
SUNON configures GF40282B3-10000-ADP as a 40 × 40 × 28 mm DC axial fan for servers and data-center electronics, operating at 24 VDC. Its 500 rpm rating defines a lower-speed operating point. Treat the pressure capability as a primary input to cooling-margin review. Check the full suffix before confirming connector details.
Read More