The ME70151V3-000U-A99 is SUNON's 12 VDC, 70 × 70 × 15 mm DC blower option for industrial electronics and equipment cooling. Its 2300 rpm rating defines a lower-speed operating point. Use the documented catalog specification when planning airflow-path design. Obtain the applicable curve before final duty-point approval.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 70x70x15mm |
| Max.Air Flow(m³/h) | 32.3 |
| Max.Pressure(Pa) | 17.4 |
| Input Power(W) | 0.57 |
| Speed(rpm) | 2300 |
| Noise(db) | 21.5 |
SUNON ME70151V3-000U-A99 supports industrial equipment with DC brushless axial fan airflow. It is intended for installations where predictable air exchange is central to equipment stability.
SUNON's DC product line is developed around MagLev motor technology, supporting low-friction rotation, energy-conscious operation and long service life in compact formats. Rigid mounting and clear breathing space help control vibration, flow loss and the acoustic result of the complete assembly.
When qualifying ME70151V3-000U-A99, give specific attention to service access. Use environmental checks during prototype approval to align enclosure cooling, mechanical integration and lifecycle sourcing expectations. Check that the selected variant suits the specified operating surroundings.
The worksheet lists 0.57 W input. Check supply capacity and operating conditions before commissioning.
The workbook marks the product as RoHS compliant. Confirm UL, TUV, VDE, or other project-specific approvals for the exact suffix.
The exact IP or protection option is not stated in the supplied row. Confirm the full suffix in the applicable SUNON datasheet.
Speed-control capability is not stated for this complete part number. Confirm the signal and controller requirements before use.
Its documented 12 VDC rating and its 2300 rpm rating defines a lower-speed operating point. allow comparison with the required duty point without assuming unlisted options.
The worksheet lists 21.5 dB. Installation distance, airflow resistance, and enclosure acoustics can change the measured result.

Within industrial electronics and equipment cooling, SUNON ME60151V3-000U-A99 serves as a 60 × 60 × 15 mm DC blower operating at 12 VDC. A listed input of 0.9 W is the model's notable electrical characteristic. During mounting verification, compare the model's rated dataset. Validate mounting and wiring from the model drawing.
Read More
For thermal management in industrial electronics and equipment cooling, the ME80201V3-000U-A99 provides a 12 VDC DC blower configuration measuring 80 × 80 × 20 mm. Its 2600 rpm rating defines a lower-speed operating point. During mounting verification, compare the model's electrical load. Validate mounting and wiring from the model drawing.
Read More
Within industrial electronics and equipment cooling, SUNON ME70201V3-000U-A99 serves as a 70 × 70 × 20 mm DC blower operating at 12 VDC. Its 2600 rpm rating defines a lower-speed operating point. Review its product configuration during acoustic assessment. Match the exact part number before approving a substitute.
Read More
Within industrial electronics and equipment cooling, SUNON ME80251V1-000U-A99 serves as a 80 × 80 × 25 mm DC blower operating at 12 VDC. Its 3200 rpm rating defines a lower-speed operating point. For procurement comparison, start with the supplied product configuration. Use the latest specification for frequency and tolerance limits.
Read More
The ME45101V1-000U-A99 is SUNON's 12 VDC, 45 × 45 × 10 mm DC blower option for industrial electronics and equipment cooling. Its 20 m³/h airflow rating suits the stated equipment-cooling role. Use the documented ventilation capacity when planning procurement comparison. Use the latest specification for frequency and tolerance limits.
Read More
SUNON ME70201V1-000U-A99 combines a 70 × 70 × 20 mm DC blower platform with a 12 VDC rating for industrial electronics and equipment cooling. 34.9 Pa maximum pressure is the standout documented duty-point value. Treat the suffix definition as a primary input to procurement comparison. Use the latest specification for frequency and tolerance limits.
Read More