Get Quote
Home > Products > By type > Axial Fans > PF92251B1-10000-A99 | SUNON 12V 4.32W 92x92x25mm 127.4m3/h DC Axial Fan for Data Center Cooling

PF92251B1-10000-A99 SUNON Axial Fan

Brand :
SUNON
Model:
PF92251B1-10000-A99 | SUNON 12V 4.32W 92x92x25mm 127.4m3/h DC Axial Fan for Data Center Cooling
Type:
Axial Fans
Industry:
Data Center Cooling
Description:

SUNON PF92251B1-10000-A99 combines a 92 × 92 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. Up to 127.4 m³/h is its most prominent listed performance figure. During operating-cost analysis, compare the model's static-pressure entry. Validate mounting and wiring from the model drawing.

Datasheet:
PF92251B1-10000-A99 | SUNON 12V 4.32W 92x92x25mm 127.4m3/h DC Axial Fan for Data Center Cooling Datasheet (Pdf)

Product Features

Rated Voltage(V)12
Size(mm)92x92x25mm
Max.Air Flow(m³/h)127.4
Max.Pressure(Pa)87.2
Input Power(W)4.32
Speed(rpm)4500
Noise(db)46.1

Product Features

Reliable Fan Cooling

For server and data-center equipment, SUNON PF92251B1-10000-A99 serves as a DC brushless axial fan. The fan supports temperature control in equipment that runs through sustained or repeated duty cycles.

The brushless DC motor architecture supports efficient electronic commutation and stable rotational performance for compact equipment cooling. Acoustic performance depends on the enclosure and operating point; low-turbulence integration helps avoid additional airflow noise.

Before adopting PF92251B1-10000-A99, engineers should evaluate mounting rigidity. Carry out thermal-load testing in equipment qualification so the chosen fan can be released with clear installation and sourcing requirements. Compare installed temperatures at representative equipment loads.

Application Industry

Frequently Asked Questions

Is PF92251B1-10000-A99 compatible with a replacement fan?

Match voltage, dimensions, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.

How can PF92251B1-10000-A99 affect operating cost?

Compare its listed 4.32 W input with the required airflow and run time. Total savings depend on the complete system duty point.

What speed is listed for PF92251B1-10000-A99?

The listed speed is 4500 rpm. Confirm frequency, control method, and duty point for the installed system.

What should be checked if PF92251B1-10000-A99 stops?

Verify supply, wiring, obstructions, impeller movement, and protection status. Use the model datasheet before replacement or repair.

What installation checks apply to PF92251B1-10000-A99?

Keep the airflow path clear, secure the frame without distortion, and follow the exact wiring diagram and voltage rating.

How should PF92251B1-10000-A99 be matched to an enclosure?

Review its 92 × 92 × 25 mm size, 127.4 m³/h airflow, 87.2 Pa pressure, system resistance, and available mounting space.

Message Form