Powerful centrifugal airflow systems for compact industrial cooling and ventilation applications.
| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() G2D180-BD18-11 | ebm-papst 400V 305W AC Centrifugal Blower for CNC Machines G2D180-BD18-11 is specified as a 400 V AC centrifugal blower for cnc machines. Its selection profile is led by 700 Pa pressure with 2,650 rpm operation. It supports exact-model comparison for OEM sourcing and replacement work. |
400 | 180 | 500 | 700 | 305 | 2650 | - | |
![]() G2D160-AF02-09 | ebm-papst 230V 305W AC Centrifugal Blower for Motor Cooling Designed around motor cooling, G2D160-AF02-09 uses a 230 V AC centrifugal blower platform. The model's defining specification is IP44 protection with 2,300 rpm operation. It supports exact-model comparison for OEM sourcing. |
230 | 160 | 300 | - | 305 | 2300 | - | |
![]() G2E140-AG02-05 | ebm-papst 230V 200W AC Centrifugal Blower for Water Heating For water heating, G2E140-AG02-05 provides a 230 V AC centrifugal blower configuration. A key model-specific detail is a 140 mm frame with thermal-overload protection. It supports exact-model comparison for OEM sourcing. |
230 | 140 | 520 | 480 | 200 | 2000 | - | |
![]() G2E120-AR77-01 | ebm-papst 230V 80W AC Centrifugal Blower for Ventilation Systems G2E120-AR77-01 combines 230 V operation with a AC centrifugal blower format for ventilation systems. Among the supplied ratings, a 120 mm frame with thermal-overload protection clearly differentiates this variant. |
230 | 120 | 260 | 280 | 80 | 2350 | - | |
![]() G1G170-AB53-80 | ebm-papst 230V 360W EC Centrifugal Blower for HVAC Built for hvac, G1G170-AB53-80 is a 230 V EC centrifugal blower. 5,830 rpm operation with 0-10 V/PWM speed control is its clearest differentiator in the supplied data. It supports exact-model comparison for OEM sourcing. |
230 | 170 | 645 | 2500 | 360 | 5830 | - | |
![]() G1G170-AB53-01 | ebm-papst 230V 360W EC Centrifugal Blower for Boiler Systems A 230 V EC centrifugal blower for boiler systems, G1G170-AB53-01 has a clearly defined selection profile. Its selection profile is led by 2,500 Pa pressure with 5,830 rpm operation. |
230 | 170 | 645 | 2500 | 360 | 5830 | - | |
![]() G1G170-AB31-53 | ebm-papst 230V 410W EC Centrifugal Blower for HVAC Targeting hvac, G1G170-AB31-53 pairs 230 V operation with a EC centrifugal blower layout. The model's defining specification is PWM speed control with 6,530 rpm operation. It supports exact-model comparison for OEM sourcing. |
230 | 170 | 380 | 3200 | 410 | 6530 | - | |
![]() G1G170-AB31-51 | ebm-papst 230V 410W EC Centrifugal Blower for Boiler Systems In boiler systems, G1G170-AB31-51 serves as a 230 V EC centrifugal blower. A key model-specific detail is PWM speed control with 6,530 rpm operation. It supports exact-model comparison for OEM sourcing and replacement work. |
230 | 170 | 380 | 3200 | 410 | 6530 | - | |
![]() G1G170-AB31-03 | ebm-papst 230V 315W EC Centrifugal Blower for Boiler Systems G1G170-AB31-03 is specified as a 230 V EC centrifugal blower for boiler systems. Among the supplied ratings, PWM speed control with 3,000 Pa pressure clearly differentiates this variant. |
230 | 170 | 645 | 3000 | 315 | 5650 | - | |
![]() G1G146-BA11-52 | ebm-papst 230V EC Centrifugal Blower for HVAC Designed around hvac, G1G146-BA11-52 uses a 230 V EC centrifugal blower platform. A 146 mm frame is its clearest differentiator in the supplied data. It supports exact-model comparison for OEM sourcing and replacement work. |
230 | 146 | - | - | - | - | - | |
![]() G1G144-AF49-01 | ebm-papst 230V 75W EC Centrifugal Blower for Printing Equipment For printing equipment, G1G144-AF49-01 provides a 230 V EC centrifugal blower configuration. The supplied specifications highlight 4,800 rpm operation with PWM speed control. It supports exact-model comparison for OEM sourcing. |
230 | 144 | 195 | 1400 | 75 | 4800 | - | |
![]() G1G108-AB17-02 | ebm-papst 24V 42W EC Centrifugal Blower for Cabinet Cooling G1G108-AB17-02 combines 24 V operation with a EC centrifugal blower format for cabinet cooling. For selection, its most distinctive listed attribute is 0-10 V/PWM speed control with a 108 mm frame. |
24 | 108 | 225 | 325 | 42 | 3000 | - | |
![]() D2E146-HT67-31 | ebm-papst 230V 400W AC Centrifugal Blower for HVAC Built for HVAC and ventilation equipment, the ebm-papst D2E146-HT67-31 is a 230 V AC centrifugal blower. Its combination of 875 m³/h airflow, 200 Pa pressure is intended to maintain controlled airflow and reduce thermal stress in demanding installations. |
- | - | - | - | - | - | - | |
![]() D2E146-AP43-22 | ebm-papst 230V 270W AC Centrifugal Blower for HVAC ebm-papst D2E146-AP43-22 is specified as an AC centrifugal blower using a 230 V supply, suited to HVAC and ventilation equipment. The available rating of 710 m³/h airflow, 500 Pa pressure enables model-specific airflow matching in OEM equipment and maintenance replacements. |
- | - | - | - | - | - | - | |
![]() D2E146-AP47-86 | ebm-papst 230V 330W AC Centrifugal Blower for HVAC For HVAC and ventilation equipment, the ebm-papst D2E146-AP47-86 provides a 230 V AC centrifugal blower solution. Performance data of 700 m³/h airflow, 625 Pa pressure supports practical selection for continuous ventilation, component cooling and replacement planning. |
- | - | - | - | - | - | - | |
![]() D2E133-AM47-94 | ebm-papst 230V 200W AC Centrifugal Blower for HVAC The D2E133-AM47-94 from ebm-papst combines 230 V operation with an AC centrifugal blower configuration for HVAC and ventilation equipment. Its documented 560 m³/h airflow, 350 Pa pressure helps engineers compare the fan with the system resistance, installation space and cooling demand. |
- | - | - | - | - | - | - | |
![]() D2E146-AP47-49 | ebm-papst 230V AC Centrifugal Blower for HVAC Designed as an AC centrifugal blower, the ebm-papst D2E146-AP47-49 operates at 230 V for HVAC and ventilation equipment. With model-specific airflow performance, it provides directed airflow for space-conscious equipment and thermal-management assemblies. |
- | - | - | - | - | - | - | |
![]() D2E146-HS97-44 | ebm-papst 230V AC Centrifugal Blower for HVAC The ebm-papst D2E146-HS97-44 is a 230 V AC centrifugal blower developed for HVAC and ventilation equipment. Its listed performance—model-specific airflow performance—supports stable heat removal and dependable operation when matched to the required duty point. |
- | - | - | - | - | - | - | |
![]() D2E146-HS97-01 | ebm-papst 230V 215W AC Centrifugal Blower for HVAC A 230 V AC centrifugal blower for HVAC and ventilation equipment, the ebm-papst D2E146-HS97-01 delivers model-specific cooling performance. Its 580 m³/h airflow, 460 Pa pressure supports efficient ventilation where reliable airflow and compact integration are important. |
- | - | - | - | - | - | - | |
![]() D2E146-AP43-B4 | ebm-papst 230V 245W AC Centrifugal Blower for HVAC The ebm-papst D2E146-AP43-B4, a 230 V AC centrifugal blower, is intended for HVAC and ventilation equipment. Listed performance includes 920 m³/h airflow, 100 Pa pressure, giving designers a clear basis for checking airflow, mounting and electrical compatibility. |
- | - | - | - | - | - | - |
Before comparing models of centrifugal Fans, write down the real operating requirements: required airflow, system static pressure, available installation space and the electrical supply on site. A selection that ignores any of these four factors usually ends in returned goods or on-site retrofits.
Voltage and control define the shortlist. Standard options include 12/24/48 V DC and 115/230 V AC; for applications where operating points move, EC fans with PWM or 0-10 V input give precise speed control, and a tach signal provides the feedback many safety systems require.
Environmental conditions eliminate unsuitable models faster than any catalog filter. Check the ambient temperature range, required IP protection for dust and moisture, and the expected service life — ball-bearing units hold their noise and airflow figures far longer than sleeve-bearing designs in vertical or high-temperature positions. If the equipment must ship into regulated markets, verify UL, CE and RoHS compliance at this stage, and set a realistic noise target in dBA so acoustic requirements do not surface after installation.
Close the selection by de-risking the order: verify stock levels, confirm production lead time, and request datasheets plus dimension drawings for the final candidates so the mounting holes and connectors are checked before purchase. Share your operating point with us and we will validate the fit 766 products in this category are ready for comparison.
Across our project record, centrifugal Fans are specified wherever equipment must stay cool and air must keep moving: data centers and server rooms, commercial refrigeration, air handling and ventilation systems, telecom and battery cabinets, industrial machinery, and power electronics in the new-energy sector. What these projects share is a simple truth — the fan is small in cost but decisive for uptime, so it deserves the same engineering attention as the equipment it protects.
In a recent retrofit project, a customer's cooling unit had to keep running while its worn fan was exchanged. We identified a current-series replacement with identical mounting dimensions and an equivalent airflow-pressure curve, confirmed the tach output compatibility, and the installation was finished within a single maintenance window.
A second frequent case is refrigeration service: a condenser or evaporator fan fails and the exact original model is on long lead time. Instead of waiting, we check bearing type, IP rating, blade diameter and speed, then offer an equivalent that restores capacity immediately — one of the most common ways our stock protects cold chain operations.
New builds and replacement projects on ebmpapst equipment follow the same path at our company: you send the required airflow, pressure and dimensions; we respond with a shortlist, performance curves and firm delivery dates.
Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.
Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.
Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.