Get Quote
Home > Products > By brand > ebmpapst > Centrifugal Fans

Centrifugal Fans

Centrifugal Fans

Powerful centrifugal airflow systems for compact industrial cooling and ventilation applications.

Types of Centrifugal Fans

Stocking Options

Environmental Options

Media

Exclude

870 results

Applied Filters

Showing
861-870
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-820 821-840 841-860 861-870
of 870
Download Table
Mfr Part # Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
D2E133-AM47-01/A03 | ebm-papst 230V 164W AC Centrifugal Blower for Inverter Cooling
D2E133-AM47-01/A03 | ebm-papst 230V 164W AC Centrifugal Blower for Inverter Cooling

Designed as an AC centrifugal blower, the ebm-papst D2E133-AM47-01/A03 operates at 230 V for inverter and drive cooling. With 100 Pa pressure, it provides directed airflow for space-conscious equipment and thermal-management assemblies.

- - - - - - -
D2E133-AM47-01/A01 | ebm-papst 230V 190W AC Centrifugal Blower for Power Cooling
D2E133-AM47-01/A01 | ebm-papst 230V 190W AC Centrifugal Blower for Power Cooling

The ebm-papst D2E133-AM47-01/A01 is a 230 V AC centrifugal blower developed for wind-power and converter cooling. Its listed performance—710 m³/h airflow, 275 Pa pressure—supports stable heat removal and dependable operation when matched to the required duty point.

- - - - - - -
D2E133-AM47-01 | ebm-papst 230V 190W AC Centrifugal Blower for Inverter Cooling
D2E133-AM47-01 | ebm-papst 230V 190W AC Centrifugal Blower for Inverter Cooling

A 230 V AC centrifugal blower for solar inverter cooling, the ebm-papst D2E133-AM47-01 delivers model-specific cooling performance. Its 710 m³/h airflow, 275 Pa pressure supports efficient ventilation where reliable airflow and compact integration are important.

- - - - - - -
D2E133-AM31-05 | ebm-papst 400V 180W AC Centrifugal Blower for Cabinet Cooling
D2E133-AM31-05 | ebm-papst 400V 180W AC Centrifugal Blower for Cabinet Cooling

The ebm-papst D2E133-AM31-05, a 400 V AC centrifugal blower, is intended for electrical and control-cabinet cooling. Listed performance includes 695 m³/h airflow, 300 Pa pressure, giving designers a clear basis for checking airflow, mounting and electrical compatibility.

- - - - - - -
D2E097-CB01-02 | ebm-papst 230V 42W AC Centrifugal Blower for Cabinet Cooling
D2E097-CB01-02 | ebm-papst 230V 42W AC Centrifugal Blower for Cabinet Cooling

Built for electrical and control-cabinet cooling, the ebm-papst D2E097-CB01-02 is a 230 V AC centrifugal blower. Its combination of 185 m³/h airflow, 220 Pa pressure is intended to maintain controlled airflow and reduce thermal stress in demanding installations.

- - - - - - -
D2E097-BI56-48 | ebm-papst 230V 100W AC Centrifugal Blower for HVAC
D2E097-BI56-48 | ebm-papst 230V 100W AC Centrifugal Blower for HVAC

ebm-papst D2E097-BI56-48 is specified as an AC centrifugal blower using a 230 V supply, suited to HVAC and ventilation equipment. The available rating of 410 m³/h airflow, 280 Pa pressure enables model-specific airflow matching in OEM equipment and maintenance replacements.

- - - - - - -
D2E097-BI56-02 | ebm-papst 230V 100W AC Centrifugal Blower for HVAC
D2E097-BI56-02 | ebm-papst 230V 100W AC Centrifugal Blower for HVAC

For HVAC and ventilation equipment, the ebm-papst D2E097-BI56-02 provides a 230 V AC centrifugal blower solution. Performance data of 410 m³/h airflow, 280 Pa pressure supports practical selection for continuous ventilation, component cooling and replacement planning.

- - - - - - -
D2E097-BE01-65 | ebm-papst 230V 54W AC Centrifugal Blower for HVAC
D2E097-BE01-65 | ebm-papst 230V 54W AC Centrifugal Blower for HVAC

The D2E097-BE01-65 from ebm-papst combines 230 V operation with an AC centrifugal blower configuration for HVAC and ventilation equipment. Its documented 270 m³/h airflow, 201 Pa pressure helps engineers compare the fan with the system resistance, installation space and cooling demand.

- - - - - - -
D1G133-AB39-52 | ebm-papst 48V 105W EC Centrifugal Blower for Inverter Cooling
D1G133-AB39-52 | ebm-papst 48V 105W EC Centrifugal Blower for Inverter Cooling

Designed as an EC centrifugal blower, the ebm-papst D1G133-AB39-52 operates at 48 V for inverter and drive cooling. With 695 m³/h airflow, 350 Pa pressure, it provides directed airflow for space-conscious equipment and thermal-management assemblies.

- - - - - - -
D1G133-AB39-22 | ebm-papst 48V 105W EC Centrifugal Blower for Inverter Cooling
D1G133-AB39-22 | ebm-papst 48V 105W EC Centrifugal Blower for Inverter Cooling

The ebm-papst D1G133-AB39-22 is a 48 V EC centrifugal blower developed for inverter and drive cooling. Its listed performance—model-specific airflow performance—supports stable heat removal and dependable operation when matched to the required duty point.

- - - - - - -
Showing
861-870
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-820 821-840 841-860 861-870
of 870
1 2 ... 35 36 37 38 39 40 41 42 43 44
GO page

About Centrifugal Fans

Powerful centrifugal airflow systems for compact industrial cooling and ventilation applications.

How to Select the Right Centrifugal Fans

Before comparing models of centrifugal Fans, write down the real operating requirements: required airflow, system static pressure, available installation space and the electrical supply on site. A selection that ignores any of these four factors usually ends in returned goods or on-site retrofits.

Voltage and control define the shortlist. Standard options include 12/24/48 V DC and 115/230 V AC; for applications where operating points move, EC fans with PWM or 0-10 V input give precise speed control, and a tach signal provides the feedback many safety systems require.

Environmental conditions eliminate unsuitable models faster than any catalog filter. Check the ambient temperature range, required IP protection for dust and moisture, and the expected service life — ball-bearing units hold their noise and airflow figures far longer than sleeve-bearing designs in vertical or high-temperature positions. If the equipment must ship into regulated markets, verify UL, CE and RoHS compliance at this stage, and set a realistic noise target in dBA so acoustic requirements do not surface after installation.

Close the selection by de-risking the order: verify stock levels, confirm production lead time, and request datasheets plus dimension drawings for the final candidates so the mounting holes and connectors are checked before purchase. Share your operating point with us and we will validate the fit 870 products in this category are ready for comparison.

Typical Applications and Use Cases for Centrifugal Fans

Across our project record, centrifugal Fans are specified wherever equipment must stay cool and air must keep moving: data centers and server rooms, commercial refrigeration, air handling and ventilation systems, telecom and battery cabinets, industrial machinery, and power electronics in the new-energy sector. What these projects share is a simple truth — the fan is small in cost but decisive for uptime, so it deserves the same engineering attention as the equipment it protects.

In a recent retrofit project, a customer's cooling unit had to keep running while its worn fan was exchanged. We identified a current-series replacement with identical mounting dimensions and an equivalent airflow-pressure curve, confirmed the tach output compatibility, and the installation was finished within a single maintenance window.

A second frequent case is refrigeration service: a condenser or evaporator fan fails and the exact original model is on long lead time. Instead of waiting, we check bearing type, IP rating, blade diameter and speed, then offer an equivalent that restores capacity immediately — one of the most common ways our stock protects cold chain operations.

New builds and replacement projects on ebmpapst equipment follow the same path at our company: you send the required airflow, pressure and dimensions; we respond with a shortlist, performance curves and firm delivery dates.

Frequently Asked Questions About Buying Centrifugal Fans

Can you replace my existing centrifugal Fans from another supplier or a discontinued model?

Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.

Can I order a single piece or request a sample before a bulk purchase?

Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.

Do you support customized or OEM versions of centrifugal Fans?

Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.

Bag

Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.