| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() G3G125-AA20-10 | ebm-papst 230V 530W EC Centrifugal Blower for HVAC G3G125-AA20-10 is specified as a 230 V EC centrifugal blower for hvac. The model's defining specification is a 125 mm frame with 13,000 rpm operation. It supports exact-model comparison for OEM sourcing and replacement work. |
230 | 125 | - | - | 530 | 13000 | - | |
![]() G3G160-AC50-01 | ebm-papst 230V 170W EC Centrifugal Blower for HVAC Designed around hvac, G3G160-AC50-01 uses a 230 V EC centrifugal blower platform. A key model-specific detail is 0-10 V/PWM speed control with a tachometer output. It supports exact-model comparison for OEM sourcing. |
230 | 160 | 630 | 475 | 170 | 2150 | - | |
![]() G3G133-DJ01-13 | ebm-papst 230V 50W EC Centrifugal Blower for HVAC For hvac, G3G133-DJ01-13 provides a 230 V EC centrifugal blower configuration. Among the supplied ratings, IP54 protection with a 133 mm frame clearly differentiates this variant. |
230 | 133 | - | - | 50 | 2100 | - | |
![]() G2E120-AR38-01 | ebm-papst 230V 110W AC Centrifugal Blower for HVAC G2E120-AR38-01 combines 230 V operation with a AC centrifugal blower format for hvac. A 120 mm frame with IP44 protection is its clearest differentiator in the supplied data. It supports exact-model comparison for OEM sourcing. |
230 | 120 | 270 | 425 | 110 | 2600 | - | |
![]() G2E108-AG63-01 | ebm-papst 230V 35W AC Centrifugal Blower for HVAC Built for hvac, G2E108-AG63-01 is a 230 V AC centrifugal blower. The supplied specifications highlight a 108 mm frame with 1,850 rpm operation. It supports exact-model comparison for OEM sourcing and replacement work. |
230 | 108 | 160 | 250 | 35 | 1850 | - | |
![]() G2E133-DN77-37 | ebm-papst 230V 110W AC Centrifugal Blower for HVAC A 230 V AC centrifugal blower for hvac, G2E133-DN77-37 has a clearly defined selection profile. The model's defining specification is IP44 protection with thermal-overload protection. |
230 | 133 | 240 | 360 | 110 | 2100 | - | |
![]() G2E140-AI28-A5 | ebm-papst 230V 205W AC Centrifugal Blower for HVAC Targeting hvac, G2E140-AI28-A5 pairs 230 V operation with a AC centrifugal blower layout. A key model-specific detail is IP44 protection with a 140 mm frame. It supports exact-model comparison for OEM sourcing. |
230 | 140 | 490 | 500 | 205 | 2350 | - | |
![]() G2E133-DN77-29 | ebm-papst 230V AC Centrifugal Blower for HVAC In hvac, G2E133-DN77-29 serves as a 230 V AC centrifugal blower. Among the supplied ratings, a 133 mm frame clearly differentiates this variant. It supports exact-model comparison for OEM sourcing and replacement work. |
230 | 133 | - | - | - | - | - | |
![]() G2E120-AR77-A6 | ebm-papst 230V 80W AC Centrifugal Blower for HVAC G2E120-AR77-A6 is specified as a 230 V AC centrifugal blower for hvac. A listed 61 dB noise value with 2,350 rpm operation is its clearest differentiator in the supplied data. |
230 | - | 255 | - | 80 | 2350 | 61 | |
![]() G2E140-PI91-09 | ebm-papst 230V AC Centrifugal Blower for HVAC Designed around hvac, G2E140-PI91-09 uses a 230 V AC centrifugal blower platform. The supplied specifications highlight a 140 mm frame. It supports exact-model comparison for OEM sourcing and replacement work. |
230 | 140 | - | - | - | - | - | |
![]() G2E140-NF33-07 | ebm-papst 230V 130W AC Centrifugal Blower for HVAC For hvac, G2E140-NF33-07 provides a 230 V AC centrifugal blower configuration. For selection, its most distinctive listed attribute is IP44 protection with thermal-overload protection. |
230 | 140 | 185 | - | 130 | 2550 | - | |
![]() G2E120-DD70-12 | ebm-papst 230V 62W AC Centrifugal Blower for HVAC G2E120-DD70-12 combines 230 V operation with a AC centrifugal blower format for hvac. Its standout data point is IP00 protection with a 120 mm frame. It supports exact-model comparison for OEM sourcing and replacement work. |
230 | 120 | 240 | 270 | 62 | 2000 | - | |
![]() G2E140-PI32-43 | ebm-papst 115V 220W AC Centrifugal Blower for HVAC Built for hvac, G2E140-PI32-43 is a 115 V AC centrifugal blower. Its selection profile is led by a 140 mm frame with thermal-overload protection. It supports exact-model comparison for OEM sourcing and replacement work. |
115 | 140 | 495 | 540 | 220 | 1970 | - | |
![]() G2E140-AI28-01 | ebm-papst 230V 160W AC Centrifugal Blower for HVAC A 230 V AC centrifugal blower for hvac, G2E140-AI28-01 has a clearly defined selection profile. Thermal-overload protection with a 140 mm frame is its clearest differentiator in the supplied data. |
230 | 140 | 500 | 400 | 160 | 2400 | - | |
![]() G4E160-AB01-01 | ebm-papst 230V 67W AC Centrifugal Blower for Inverter Cooling Targeting inverter cooling, G4E160-AB01-01 pairs 230 V operation with a AC centrifugal blower layout. The supplied specifications highlight thermal-overload protection with a 160 mm frame. |
230 | 160 | 410 | 148 | 67 | 1300 | - | |
![]() G4D355-CM15-XA/F02 | ebm-papst 400V 4380W AC Centrifugal Blower for Wind Turbines In wind turbines, G4D355-CM15-XA/F02 serves as a 400 V AC centrifugal blower. For selection, its most distinctive listed attribute is a listed 40 dB noise value with 6,620 m³/h airflow. |
400 | 355 | 6620 | 400 | 4380 | 1320 | 40 | |
![]() G4D310-DK03-05/F02 | ebm-papst 400V 2180W AC Centrifugal Blower for Wind Inverters G4D310-DK03-05/F02 is specified as a 400 V AC centrifugal blower for wind inverters. Its standout data point is a 2,180 W input rating with thermal-overload protection. It supports exact-model comparison for OEM sourcing. |
400 | 310 | - | - | 2180 | 1310 | - | |
![]() G4D200-CL12-01 | ebm-papst 400V 340W AC Centrifugal Blower for Wind Turbines Designed around wind turbines, G4D200-CL12-01 uses a 400 V AC centrifugal blower platform. Its selection profile is led by 1,270 m³/h airflow with a 340 W input rating. It supports exact-model comparison for OEM sourcing. |
400 | 200 | 1270 | 250 | 340 | 1550 | - | |
![]() G4D200-CD04-28 | ebm-papst 400V 210W AC Centrifugal Blower for Power Electronics For power electronics, G4D200-CD04-28 provides a 400 V AC centrifugal blower configuration. The model's defining specification is IP44 protection with 1,020 m³/h airflow. It supports exact-model comparison for OEM sourcing. |
400 | 200 | 1020 | 240 | 210 | 1370 | - | |
![]() G4D200-CD04-24 | ebm-papst 400V 310W AC Centrifugal Blower for Filter Cabinets G4D200-CD04-24 combines 400 V operation with a AC centrifugal blower format for filter cabinets. A key model-specific detail is 1,145 m³/h airflow with thermal-overload protection. |
400 | 200 | 1145 | 340 | 310 | 1530 | - |
The most reliable way to specify centrifugal Fans is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.
Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.
Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.
End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 1,626 products are available in this category today.
The daily work of our sales engineers is built around centrifugal Fans used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.
A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.
Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.
From one-piece emergency replacements to volume supply for equipment manufacturers, every enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.
Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.
Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.
Every unit is covered by the manufacturer's warranty against defects in materials and workmanship, and we support you through the whole claim process so you deal with one supplier instead of chasing a factory overseas. If a failure appears in service, send us the serial number, operating conditions and photos, and we will arrange the replacement or credit path agreed in the quotation.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.