| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() A6E500-AJ05-01 | ebm-papst 230V 290W AC Axial Fan for Refrigeration ebm-papst A6E500-AJ05-01 is specified as an AC axial fan using a 230 V supply, suited to refrigeration and cooling equipment. The available rating of 6630 m³/h airflow, 57 Pa pressure, 810 RPM enables model-specific airflow matching in OEM equipment and maintenance replacements. |
230 | 500 | 6630 | 57 | 290 | 810 | 54 | |
![]() A6E630-AN01-01 | ebm-papst 230V 600W AC Axial Fan for HVAC/R For hvac/r, the ebm-papst A6E630-AN01-01 provides a 230 V AC axial fan solution. Performance data of 6725 m³/h airflow, 860 RPM supports practical selection for continuous ventilation, component cooling and replacement planning. |
230 | 630 | 6725 | - | 600 | 860 | - | |
![]() A6D800-AU01-01 | ebm-papst 400V 2330W AC Axial Fan for HVAC/R The A6D800-AU01-01 from ebm-papst combines 400 V operation with an AC axial fan configuration for hvac/r. Its documented 26920 m³/h airflow, 120 Pa pressure, 900 RPM helps engineers compare the fan with the system resistance, installation space and cooling demand. |
400 | 800 | 26920 | 120 | 2330 | 900 | 69 | |
![]() A6D910-AB05-03 | ebm-papst 480V 2870W AC Axial Fan for HVAC/R Designed as an AC axial fan, the ebm-papst A6D910-AB05-03 operates at 480 V for hvac/r. With 33645 m³/h airflow, 140 Pa pressure, 1100 RPM, it provides directed airflow for space-conscious equipment and thermal-management assemblies. |
480 | 910 | 33645 | 140 | 2870 | 1100 | 73 | |
![]() A6D800-AJ01-01 | ebm-papst 400V 2000W AC Axial Fan for HVAC/R The ebm-papst A6D800-AJ01-01 is a 400 V AC axial fan developed for hvac/r. Its listed performance—24530 m³/h airflow, 180 Pa pressure, 895 RPM—supports stable heat removal and dependable operation when matched to the required duty point. |
400 | 800 | 24530 | 180 | 2000 | 895 | 71 | |
![]() A6D800-AE01-01 | ebm-papst 480V 1090W AC Axial Fan for HVAC/R A 480 V AC axial fan for hvac/r, the ebm-papst A6D800-AE01-01 delivers model-specific cooling performance. Its 25255 m³/h airflow, 120 Pa pressure, 2060 RPM supports efficient ventilation where reliable airflow and compact integration are important. |
480 | 800 | 25255 | 120 | 1090 | 2060 | 69 | |
![]() A6D910-AE01-01 | ebm-papst 400V 1840W AC Axial Fan for Refrigeration The ebm-papst A6D910-AE01-01, a 400 V AC axial fan, is intended for refrigeration and cooling equipment. Listed performance includes 27800 m³/h airflow, 145 Pa pressure, 890 RPM, giving designers a clear basis for checking airflow, mounting and electrical compatibility. |
400 | 910 | 27800 | 145 | 1840 | 890 | 71 | |
![]() A6D800-AE05-03 | ebm-papst 480V 2180W AC Axial Fan for Refrigeration Built for refrigeration and cooling equipment, the ebm-papst A6D800-AE05-03 is a 480 V AC axial fan. Its combination of 25190 m³/h airflow, 150 Pa pressure, 1080 RPM is intended to maintain controlled airflow and reduce thermal stress in demanding installations. |
480 | 800 | 25190 | 150 | 2180 | 1080 | 70 | |
![]() A4E300-AR26-17 | ebm-papst 230V 95W AC Axial Fan for HVAC/R Designed as an AC axial fan, the ebm-papst A4E300-AR26-17 operates at 230 V for hvac/r. With 2215 m³/h airflow, 70 Pa pressure, 1570 RPM, it provides directed airflow for space-conscious equipment and thermal-management assemblies. |
230 | 300 | 2215 | 70 | 95 | 1570 | 61 | |
![]() A4E300-AS72-53 | ebm-papst 230V 70W AC Axial Fan for HVAC/R The ebm-papst A4E300-AS72-53 is a 230 V AC axial fan developed for hvac/r. Its listed performance—1800 m³/h airflow, 60 Pa pressure, 1350 RPM—supports stable heat removal and dependable operation when matched to the required duty point. |
230 | 300 | 1800 | 60 | 70 | 1350 | 51 | |
![]() A4E400-AP02-14 | ebm-papst 230V 160W AC Axial Fan for HVAC/R A 230 V AC axial fan for hvac/r, the ebm-papst A4E400-AP02-14 delivers model-specific cooling performance. Its 4235 m³/h airflow, 100 Pa pressure, 1430 RPM supports efficient ventilation where reliable airflow and compact integration are important. |
230 | 400 | 4235 | 100 | 160 | 1430 | 65 | |
![]() A4E300-AS72-52 | ebm-papst 230V 90W AC Axial Fan for HVAC/R The ebm-papst A4E300-AS72-52, a 230 V AC axial fan, is intended for hvac/r. Listed performance includes 1335 m³/h airflow, 60 Pa pressure, 1500 RPM, giving designers a clear basis for checking airflow, mounting and electrical compatibility. |
230 | 300 | 1335 | 60 | 90 | 1500 | 55 | |
![]() A4E450-BA09-01 | ebm-papst 230V 665W AC Axial Fan for HVAC/R Built for hvac/r, the ebm-papst A4E450-BA09-01 is a 230 V AC axial fan. Its combination of 7815 m³/h airflow, 115 Pa pressure, 1490 RPM is intended to maintain controlled airflow and reduce thermal stress in demanding installations. |
230 | 450 | 7815 | 115 | 665 | 1490 | - | |
![]() A4E300-AS72-02 | ebm-papst 230V 90W AC Axial Fan for HVAC/R ebm-papst A4E300-AS72-02 is specified as an AC axial fan using a 230 V supply, suited to hvac/r. The available rating of 2070 m³/h airflow, 60 Pa pressure, 1500 RPM enables model-specific airflow matching in OEM equipment and maintenance replacements. |
230 | 300 | 2070 | 60 | 90 | 1500 | 55 | |
![]() A4E350-AP06-02 | ebm-papst 230V 190W AC Axial Fan for HVAC/R For hvac/r, the ebm-papst A4E350-AP06-02 provides a 230 V AC axial fan solution. Performance data of 3540 m³/h airflow, 60 Pa pressure, 1590 RPM supports practical selection for continuous ventilation, component cooling and replacement planning. |
230 | 350 | 3540 | 60 | 190 | 1590 | - | |
A4E450-AO09-01 | ebm-papst 230V 650W AC Axial Fan for HVAC/R The A4E450-AO09-01 from ebm-papst combines 230 V operation with an AC axial fan configuration for hvac/r. Its documented 7860 m³/h airflow, 115 Pa pressure, 1390 RPM helps engineers compare the fan with the system resistance, installation space and cooling demand. |
230 | 450 | 7860 | 115 | 650 | 1390 | 62 | |
![]() A4E300-AS72-11 | ebm-papst 230V 90W AC Axial Fan for HVAC/R Designed as an AC axial fan, the ebm-papst A4E300-AS72-11 operates at 230 V for hvac/r. With 2070 m³/h airflow, 60 Pa pressure, 1500 RPM, it provides directed airflow for space-conscious equipment and thermal-management assemblies. |
230 | 300 | 2070 | 60 | 90 | 1500 | 55 | |
![]() A4E350-AQ02-13 | ebm-papst 230V 275W AC Axial Fan for HVAC/R The ebm-papst A4E350-AQ02-13 is a 230 V AC axial fan developed for hvac/r. Its listed performance—2815 m³/h airflow, 1660 RPM—supports stable heat removal and dependable operation when matched to the required duty point. |
230 | 350 | 2815 | - | 275 | 1660 | - | |
![]() A4E420-AU01-05 | ebm-papst 230V 370W AC Axial Fan for HVAC/R A 230 V AC axial fan for hvac/r, the ebm-papst A4E420-AU01-05 delivers model-specific cooling performance. Its 5475 m³/h airflow, 75 Pa pressure, 1430 RPM supports efficient ventilation where reliable airflow and compact integration are important. |
230 | 420 | 5475 | 75 | 370 | 1430 | - | |
![]() A4E500-AM03-01 | ebm-papst 230V 880W AC Axial Fan for Refrigeration The ebm-papst A4E500-AM03-01, a 230 V AC axial fan, is intended for refrigeration and cooling equipment. Listed performance includes 9850 m³/h airflow, 100 Pa pressure, 1400 RPM, giving designers a clear basis for checking airflow, mounting and electrical compatibility. |
230 | 500 | 9850 | 100 | 880 | 1400 | 65 |
Before comparing models of refrigeration Equipment, write down the real operating requirements: required airflow, system static pressure, available installation space and the electrical supply on site. A selection that ignores any of these four factors usually ends in returned goods or on-site retrofits.
Voltage and control define the shortlist. Standard options include 12/24/48 V DC and 115/230 V AC; for applications where operating points move, EC fans with PWM or 0-10 V input give precise speed control, and a tach signal provides the feedback many safety systems require.
Environmental conditions eliminate unsuitable models faster than any catalog filter. Check the ambient temperature range, required IP protection for dust and moisture, and the expected service life — ball-bearing units hold their noise and airflow figures far longer than sleeve-bearing designs in vertical or high-temperature positions. If the equipment must ship into regulated markets, verify UL, CE and RoHS compliance at this stage, and set a realistic noise target in dBA so acoustic requirements do not surface after installation.
Close the selection by de-risking the order: verify stock levels, confirm production lead time, and request datasheets plus dimension drawings for the final candidates so the mounting holes and connectors are checked before purchase. Share your operating point with us and we will validate the fit 487 products in this category are ready for comparison.
Across our project record, refrigeration Equipment are specified wherever equipment must stay cool and air must keep moving: data centers and server rooms, commercial refrigeration, air handling and ventilation systems, telecom and battery cabinets, industrial machinery, and power electronics in the new-energy sector. What these projects share is a simple truth — the fan is small in cost but decisive for uptime, so it deserves the same engineering attention as the equipment it protects.
In a recent retrofit project, a customer's cooling unit had to keep running while its worn fan was exchanged. We identified a current-series replacement with identical mounting dimensions and an equivalent airflow-pressure curve, confirmed the tach output compatibility, and the installation was finished within a single maintenance window.
A second frequent case is refrigeration service: a condenser or evaporator fan fails and the exact original model is on long lead time. Instead of waiting, we check bearing type, IP rating, blade diameter and speed, then offer an equivalent that restores capacity immediately — one of the most common ways our stock protects cold chain operations.
New builds and replacement projects follow the same path: you send the required airflow, pressure and dimensions; we respond with a shortlist, performance curves and firm delivery dates.
Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.
Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.
Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.