Get Quote
Home > Products > By industry > Refrigeration Equipment

Refrigeration Equipment

By brand

By type

Rated Voltage(V)

Size(mm)

Max.Air Flow(m³/h)

Max.Pressure(Pa)

Input Power(W)

Speed(rpm)

Noise(db)

Stocking Options

Environmental Options

Media

Exclude

487 results

Applied Filters

Showing
481-487
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-487
of 487
Download Table
Mfr Part # Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
A4D630-AH01-02 | ebm-papst 400V 1970W AC Axial Fan for Refrigeration

The ebm-papst A4D630-AH01-02 is a 400 V AC axial fan developed for refrigeration and cooling equipment. Its listed performance—1310 RPM—supports stable heat removal and dependable operation when matched to the required duty point.

400 630 - - 1970 1310 -
A4D560-AQ01-02 | ebm-papst 400V 1110W AC Axial Fan for Refrigeration

A 400 V AC axial fan for refrigeration and cooling equipment, the ebm-papst A4D560-AQ01-02 delivers model-specific cooling performance. Its 11975 m³/h airflow, 170 Pa pressure, 1350 RPM supports efficient ventilation where reliable airflow and compact integration are important.

400 560 11975 170 1110 1350 70
A4D560-AR03-03 | ebm-papst 400V AC Axial Fan for Refrigeration

The ebm-papst A4D560-AR03-03, a 400 V AC axial fan, is intended for refrigeration and cooling equipment. Listed performance includes 12000 m³/h airflow, 305 Pa pressure, giving designers a clear basis for checking airflow, mounting and electrical compatibility.

400 560 12000 305 - - -
A4D560-AM03-01 | ebm-papst 400V 1160W AC Axial Fan for Refrigeration

Built for refrigeration and cooling equipment, the ebm-papst A4D560-AM03-01 is a 400 V AC axial fan. Its combination of 12600 m³/h airflow, 140 Pa pressure, 1295 RPM is intended to maintain controlled airflow and reduce thermal stress in demanding installations.

400 560 12600 140 1160 1295 74
A4D500-AM03-02 | ebm-papst 460V 1060W AC Axial Fan for Refrigeration

ebm-papst A4D500-AM03-02 is specified as an AC axial fan using a 460 V supply, suited to refrigeration and cooling equipment. The available rating of 10920 m³/h airflow, 138 Pa pressure, 1640 RPM enables model-specific airflow matching in OEM equipment and maintenance replacements.

460 500 10920 138 1060 1640 68
A4D500-AM03-01 | ebm-papst 460V 1060W AC Axial Fan for Refrigeration

For refrigeration and cooling equipment, the ebm-papst A4D500-AM03-01 provides a 460 V AC axial fan solution. Performance data of 10920 m³/h airflow, 138 Pa pressure, 1640 RPM supports practical selection for continuous ventilation, component cooling and replacement planning.

460 500 10920 138 1060 1640 68
A4D500-AJ03-01 | ebm-papst 400V 710W AC Axial Fan for Refrigeration

The A4D500-AJ03-01 from ebm-papst combines 400 V operation with an AC axial fan configuration for refrigeration and cooling equipment. Its documented 9030 m³/h airflow, 140 Pa pressure, 1340 RPM helps engineers compare the fan with the system resistance, installation space and cooling demand.

400 500 9030 140 710 1340 64
Showing
481-487
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-487
of 487
1 2 ... 16 17 18 19 20 21 22 23 24 25
GO page

About Refrigeration Equipment

Refrigeration and cold chain cooling systems

How to Select the Right Refrigeration Equipment

Before comparing models of refrigeration Equipment, write down the real operating requirements: required airflow, system static pressure, available installation space and the electrical supply on site. A selection that ignores any of these four factors usually ends in returned goods or on-site retrofits.

Voltage and control define the shortlist. Standard options include 12/24/48 V DC and 115/230 V AC; for applications where operating points move, EC fans with PWM or 0-10 V input give precise speed control, and a tach signal provides the feedback many safety systems require.

Environmental conditions eliminate unsuitable models faster than any catalog filter. Check the ambient temperature range, required IP protection for dust and moisture, and the expected service life — ball-bearing units hold their noise and airflow figures far longer than sleeve-bearing designs in vertical or high-temperature positions. If the equipment must ship into regulated markets, verify UL, CE and RoHS compliance at this stage, and set a realistic noise target in dBA so acoustic requirements do not surface after installation.

Close the selection by de-risking the order: verify stock levels, confirm production lead time, and request datasheets plus dimension drawings for the final candidates so the mounting holes and connectors are checked before purchase. Share your operating point with us and we will validate the fit 487 products in this category are ready for comparison.

Typical Applications and Use Cases for Refrigeration Equipment

Across our project record, refrigeration Equipment are specified wherever equipment must stay cool and air must keep moving: data centers and server rooms, commercial refrigeration, air handling and ventilation systems, telecom and battery cabinets, industrial machinery, and power electronics in the new-energy sector. What these projects share is a simple truth — the fan is small in cost but decisive for uptime, so it deserves the same engineering attention as the equipment it protects.

In a recent retrofit project, a customer's cooling unit had to keep running while its worn fan was exchanged. We identified a current-series replacement with identical mounting dimensions and an equivalent airflow-pressure curve, confirmed the tach output compatibility, and the installation was finished within a single maintenance window.

A second frequent case is refrigeration service: a condenser or evaporator fan fails and the exact original model is on long lead time. Instead of waiting, we check bearing type, IP rating, blade diameter and speed, then offer an equivalent that restores capacity immediately — one of the most common ways our stock protects cold chain operations.

New builds and replacement projects follow the same path: you send the required airflow, pressure and dimensions; we respond with a shortlist, performance curves and firm delivery dates.

Frequently Asked Questions About Buying Refrigeration Equipment

Can you replace my existing refrigeration Equipment from another supplier or a discontinued model?

Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.

Can I order a single piece or request a sample before a bulk purchase?

Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.

Do you support customized or OEM versions of refrigeration Equipment?

Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.

Bag

Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.