| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() 9WF0424H7D01 | Sanyo Denki 24VDC DC Axial Fan for industrial equipment and cabinet cooling The 9WF0424H7D01 is a Sanyo Denki 24 VDC, 40 × 40 × 15 mm DC axial fan for industrial controls, power cabinets, and energy systems. Its oil-resistant fan design and IP20 listing is the defining supplied feature. The recorded catalog specification should guide service-life planning. Validate mounting and wiring from the model drawing. |
24 | 40*40*15 | - | - | - | - | - | |
![]() 9CR5748G9003 | Sanyo Denki 48VDC Counter-Rotating DC Axial Fan for UPS, server and telecom equipment cooling The size not stated Sanyo Denki 9CR5748G9003 brings 48 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Series options require suffix verification. Base duty-point matching on the stated airflow profile. Use the latest specification for frequency and tolerance limits. Focus: power budget review rotational rating. |
48 | - | - | - | - | - | - | |
![]() 9G1224M402 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki 9G1224M402 is a 24 VDC DC axial fan in a 120 × 120 × 25 mm format for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. The 120 × 120 × 25 mm format is the primary stated selection detail. Check power budget review frame geometry. Focus: power budget review. |
24 | 120*120*25 | - | - | - | - | - | |
![]() 109P0424H6D18 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling The 109P0424H6D18 is a Sanyo Denki 24 VDC, 40 × 40 × 20 mm DC axial fan for servers, UPS systems, and telecom equipment. The supplied reference emphasizes high static pressure and high airflow. Review its frame geometry during duty-point matching. Treat bearing and life data as suffix-specific. Selection focus: power budget review operating point. |
24 | 40*40*20 | - | - | - | - | - | |
![]() 109R0824S402 | Sanyo Denki 24VDC 2.4W DC Axial Fan for UPS, server and telecom equipment cooling A 80 × 80 × 25 mm frame and 24 VDC rating define 109R0824S402, a DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. 48.1 Pa maximum pressure is the most distinctive duty-point parameter. Check power budget review pressure capability. Focus: power budget review pressure capability. |
24 | 80*80*25 | 72.08 | 48.1 | 2.4 | 3400 | 34 | |
![]() 109E1724H502 | Sanyo Denki 24VDC 13.92W DC Axial Fan for UPS, server and telecom equipment cooling Within servers, UPS systems, and telecom equipment, 109E1724H502 provides a ø172 × 51 mm, 24 VDC DC axial fan configuration. High airflow is highlighted together with a high-static-pressure design. Its listed airflow of 384 m³/h is the standout performance value. Check power budget review dimensional envelope. Focus: power budget review. |
24 | ø172*51 | 384 | 137.2 | 13.92 | 3050 | 47 | |
![]() 9G1224M4021 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling A 120 × 120 × 25 mm frame and 24 VDC rating define 9G1224M4021, a DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. The 120 × 120 × 25 mm format is the primary stated selection detail. Check power budget review acoustic value. Focus: power budget review acoustic value. |
24 | 120*120*25 | - | - | - | - | - | |
![]() 109E1724C503 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki configures 109E1724C503 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with ø172 × 51 mm dimensions. The ø172 × 51 mm format is the primary stated selection detail. Treat the system interface as a primary input to airflow-path design. Use the latest specification for frequency and tolerance limits. |
24 | ø172*51 | - | - | - | - | - | |
![]() 9G1224M401 | Sanyo Denki 24VDC 1.92W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki configures 9G1224M401 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 120 × 120 × 25 mm dimensions. Its 1950 rpm rating defines a lower-speed operating point. Use the documented pressure capability when planning replacement evaluation. Validate mounting and wiring from the model drawing. |
24 | 120*120*25 | 100 | 31 | 1.92 | 1950 | 29 | |
![]() 109P1224H4021 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling 109P1224H4021 serves servers, UPS systems, and telecom equipment as a 120 × 120 × 25 mm DC axial fan rated at 24 VDC. High airflow is highlighted together with a high-static-pressure design. The 120 × 120 × 25 mm format is the primary stated selection detail. Check power budget review airflow profile. Focus: power budget review airflow profile. |
24 | 120*120*25 | - | - | - | - | - | |
![]() 9GV0812P1H04 | Sanyo Denki 12VDC DC Axial Fan for automation and control cabinet cooling Built around industrial controls, power cabinets, and energy systems, Sanyo Denki 9GV0812P1H04 is a 12 VDC DC axial fan in a 80 × 80 × 38 mm frame. The 80 × 80 × 38 mm format is the primary stated selection detail. High airflow is highlighted together with a high-static-pressure design. Focus: resistance curve checking cooling specification. |
12 | 80*80*38 | - | - | - | - | - | |
![]() 9WF0924H203 | Sanyo Denki 24VDC DC Axial Fan for industrial equipment and cabinet cooling The 9WF0924H203 is a Sanyo Denki 24 VDC, 92 × 92 × 32 mm DC axial fan for industrial controls, power cabinets, and energy systems. Its oil-resistant fan design and IP20 listing is the defining supplied feature. The recorded rated dataset should guide enclosure sizing. Obtain the applicable curve before final duty-point approval. |
24 | 92*92*32 | - | - | - | - | - | |
![]() 109P0424H701 | Sanyo Denki 24VDC 1.92W DC Axial Fan for UPS, server and telecom equipment cooling For servers, UPS systems, and telecom equipment, 109P0424H701 combines 24 VDC operation with a 40 × 40 × 15 mm DC axial fan design. High airflow is highlighted together with a high-static-pressure design. The 10.8 m³/h airflow figure supports its stated equipment-cooling role. Check resistance curve checking installation footprint. |
24 | 40*40*15 | 10.8 | 75.5 | 1.92 | 7700 | 28 | |
![]() 9WG1224J103 | Sanyo Denki 24VDC DC Axial Fan for solar inverter and energy storage cooling Sanyo Denki 9WG1224J103 combines a 120 × 120 × 38 mm DC axial fan platform with a 24 VDC rating for outdoor equipment and photovoltaic inverters. Any PWM input or speed signal must be confirmed against the ordered suffix. The 120 × 120 × 38 mm format is the primary stated selection detail. Focus: resistance curve checking selection parameters. |
24 | 120*120*38 | - | - | - | - | - | |
![]() 109P0424H316 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki configures 109P0424H316 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 40 × 40 × 28 mm dimensions. The 40 × 40 × 28 mm format is the primary stated selection detail. The recorded motor input should guide spares assessment. Match the exact part number before approving a substitute. |
24 | 40*40*28 | - | - | - | - | - | |
![]() 109P1224H402 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki configures 109P1224H402 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 120 × 120 × 25 mm dimensions. The 120 × 120 × 25 mm format is the primary stated selection detail. The recorded supply requirement should guide enclosure sizing. Verify the exact bearing and signal options in the datasheet. |
24 | 120*120*25 | - | - | - | - | - | |
![]() 9WF0624H404 | Sanyo Denki 24VDC DC Axial Fan for industrial equipment and cabinet cooling For industrial controls, power cabinets, and energy systems, 9WF0624H404 combines 24 VDC operation with a 60 × 60 × 25 mm DC axial fan design. Its oil-resistant fan design and IP20 listing is the defining supplied feature. The 60 × 60 × 25 mm format is the primary stated selection detail. Focus: resistance curve checking ventilation capacity. |
24 | 60*60*25 | - | - | - | - | - | |
![]() 109P0405F602 | Sanyo Denki 5VDC DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki configures 109P0405F602 for servers, UPS systems, and telecom equipment as a 5 VDC DC axial fan with 40 × 40 × 20 mm dimensions. The 40 × 40 × 20 mm format is the primary stated selection detail. Review its electrical load during procurement comparison. Use the latest specification for frequency and tolerance limits. |
5 | 40*40*20 | - | - | - | - | - | |
![]() 9G1224H402 | Sanyo Denki 24VDC 4.08W DC Axial Fan for UPS, server and telecom equipment cooling The 119 × 119 × 25 mm Sanyo Denki 9G1224H402 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Use the documented mounting size when planning power-budget planning. Obtain the applicable curve before final duty-point approval. Focus: resistance curve checking. |
24 | 119*119*25 | 149.6 | 64 | 4.08 | 2850 | 40 | |
![]() 9GA0424H3003 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling 9GA0424H3003 addresses servers, UPS systems, and telecom equipment through a 24 VDC DC axial fan platform measuring 40 × 40 × 28 mm. Long-life series construction is the main characteristic stated in the supplied reference. The 40 × 40 × 28 mm format is the primary stated selection detail. Focus: resistance curve checking thermal-duty record. |
24 | 40*40*28 | - | - | - | - | - |
The most reliable way to specify san Ace Dc Fan is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.
Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.
Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.
End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 540 products are available in this category today.
The daily work of our sales engineers is built around san Ace Dc Fan used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.
A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.
Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.
From one-piece emergency replacements to volume supply for equipment manufacturers, every Sanyo enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.
Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.
Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.
Every unit is covered by the manufacturer's warranty against defects in materials and workmanship, and we support you through the whole claim process so you deal with one supplier instead of chasing a factory overseas. If a failure appears in service, send us the serial number, operating conditions and photos, and we will arrange the replacement or credit path agreed in the quotation.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.