The GF40282B1-10000-SDP is SUNON's 24 VDC, 40 × 40 × 28 mm DC axial fan option for servers and data-center electronics. 14600 W input is the defining electrical load in the supplied data. Use the documented airflow profile when planning cooling-margin review. Check the full suffix before confirming connector details.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 40x40x28mm |
| Max.Air Flow(m³/h) | 34.7 |
| Max.Pressure(Pa) | 351.2 |
| Input Power(W) | 14600 |
| Speed(rpm) | 14600 |
| Noise(db) | 54 |
Designed for industrial equipment, the SUNON GF40282B1-10000-SDP provides DC brushless axial fan cooling in a format suited to equipment integration. It helps limit local heat buildup during operation.
The brushless DC motor architecture supports efficient electronic commutation and stable rotational performance for compact equipment cooling. Rigid mounting and clear breathing space help control vibration, flow loss and the acoustic result of the complete assembly.
For GF40282B1-10000-SDP integration, prioritize inlet clearance. Include replacement-fit checks in engineering approval, and confirm the full model interface before design lock. This supports reliable cooling and traceable purchasing. Verify mounting, connector and airflow direction against the replacement space.
Keep the airflow path clear, secure the frame without distortion, and follow the exact wiring diagram and voltage rating.
Use the listed voltage, size, 34.7 m³/h airflow, 14600 rpm, and 14600 W input for preliminary comparison.
The workbook marks the product as RoHS compliant. Confirm UL, TUV, VDE, or other project-specific approvals for the exact suffix.
Confirm any missing bearing, connector, control, IP rating, life, certification, and performance-curve details for the complete part number.
Inspect for dust, blocked airflow, abnormal noise, loose mounting, and wiring damage. Isolate power before cleaning or service.
Its documented 24 VDC rating and 14600 w input is the defining electrical load in the supplied data. allow comparison with the required duty point without assuming unlisted options.

Within servers and data-center electronics, SUNON GF40282B3-10000-SDP serves as a 40 × 40 × 28 mm DC axial fan operating at 24 VDC. 10500 W input is the defining electrical load in the supplied data. For cooling-margin review, start with the supplied frame geometry. Check the full suffix before confirming connector details.
Read More
SUNON GF40282B2-10000-SDP combines a 40 × 40 × 28 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. 13100 W input is the defining electrical load in the supplied data. Base cooling-margin review on the stated dimensional envelope. Check the full suffix before confirming connector details.
Read More
GF40282B3-10000-QDP addresses servers and data-center electronics through a 24 VDC DC axial fan platform measuring 40 × 40 × 28 mm. 10500 W input is the defining electrical load in the supplied data. Use the documented cooling output when planning cooling-margin review. Check the full suffix before confirming connector details.
Read More
The GF40282B3-10000-AEP is SUNON's 24 VDC, 40 × 40 × 28 mm DC axial fan option for servers and data-center electronics. Its 500 rpm rating defines a lower-speed operating point. Review its operating point during cooling-margin review. Check the full suffix before confirming connector details.
Read More
SUNON configures GF40282B3-10000-ADP as a 40 × 40 × 28 mm DC axial fan for servers and data-center electronics, operating at 24 VDC. Its 500 rpm rating defines a lower-speed operating point. Treat the pressure capability as a primary input to cooling-margin review. Check the full suffix before confirming connector details.
Read More
Applied in servers and data-center electronics, SUNON GF40282B2-10000-QDP is a 24 VDC DC axial fan in a 40 × 40 × 28 mm frame. 13100 W input is the defining electrical load in the supplied data. During cooling-margin review, compare the model's acoustic value. Check the full suffix before confirming connector details.
Read More