Get Quote
Home > Products > By type > Axial Fans > GF60151B9-1E000-AC9 | SUNON 12V 0.39W 60x60x15mm 18m3/h DC Axial Fan for Data Center Cooling

GF60151B9-1E000-AC9 SUNON Axial Fan

Brand :
SUNON
Model:
GF60151B9-1E000-AC9 | SUNON 12V 0.39W 60x60x15mm 18m3/h DC Axial Fan for Data Center Cooling
Type:
Axial Fans
Industry:
Data Center Cooling
Description:

Built for servers and data-center electronics, SUNON GF60151B9-1E000-AC9 uses a 60 × 60 × 15 mm DC axial fan arrangement at 12 VDC. A listed input of 0.39 W is the model's notable electrical characteristic. Treat the suffix definition as a primary input to cooling-margin review. Check the full suffix before confirming connector details.

Datasheet:
GF60151B9-1E000-AC9 | SUNON 12V 0.39W 60x60x15mm 18m3/h DC Axial Fan for Data Center Cooling Datasheet (Pdf)

Product Features

Rated Voltage(V)12
Size(mm)60x60x15mm
Max.Air Flow(m³/h)18
Max.Pressure(Pa)12.5
Input Power(W)0.39
Speed(rpm)2300
Noise(db)17.1

Product Features

Low Noise Cooling

SUNON GF60151B9-1E000-AC9 brings active air movement to server and data-center equipment. This DC brushless axial fan helps equipment designers control thermal conditions around densely arranged parts.

The brushless DC motor architecture supports efficient electronic commutation and stable rotational performance for compact equipment cooling. The enclosure should direct air across the heat source because bypass flow can reduce cooling even when the fan runs normally.

The final GF60151B9-1E000-AC9 selection should consider connector reach as part of the installation layout. Finishing wiring verification before design lock helps reduce integration uncertainty and supports reliable equipment cooling. Confirm that the mating lead reaches without tension or sharp bending.

Application Industry

Frequently Asked Questions

What installation checks apply to GF60151B9-1E000-AC9?

Keep the airflow path clear, secure the frame without distortion, and follow the exact wiring diagram and voltage rating.

What input power is listed for GF60151B9-1E000-AC9?

The worksheet lists 0.39 W input. Check supply capacity and operating conditions before commissioning.

What equipment can use GF60151B9-1E000-AC9?

It is listed for servers and data-center electronics. Check dimensions, airflow, pressure, and the installation environment against the actual equipment.

What protection rating does GF60151B9-1E000-AC9 have?

The exact IP or protection option is not stated in the supplied row. Confirm the full suffix in the applicable SUNON datasheet.

What maintenance is recommended for GF60151B9-1E000-AC9?

Inspect for dust, blocked airflow, abnormal noise, loose mounting, and wiring damage. Isolate power before cleaning or service.

Message Form