The 40 × 40 × 28 mm GF60252B3-10000-QDP brings 24 VDC DC axial fan cooling to servers and data-center electronics. 6450 W input is the defining electrical load in the supplied data. During cooling-margin review, compare the model's technical profile. Check the full suffix before confirming connector details.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 40x40x28mm |
| Max.Air Flow(m³/h) | 46.6 |
| Max.Pressure(Pa) | 94.7 |
| Input Power(W) | 6450 |
| Speed(rpm) | 6450 |
| Noise(db) | 41.7 |
SUNON GF60252B3-10000-QDP is a DC brushless axial fan for industrial equipment. It establishes forced airflow where passive cooling cannot adequately protect heat-producing assemblies.
The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market. The enclosure should direct air across the heat source because bypass flow can reduce cooling even when the fan runs normally.
Design approval for GF60252B3-10000-QDP should cover cable routing together with system-resistance review before design lock. This creates a practical link between thermal validation, purchasing documentation and future servicing. Secure conductors away from the impeller and high-temperature components.
The exact IP or protection option is not stated in the supplied row. Confirm the full suffix in the applicable SUNON datasheet.
Inspect for dust, blocked airflow, abnormal noise, loose mounting, and wiring damage. Isolate power before cleaning or service.
Stock and lead time can change. Confirm the exact suffix, quantity, and delivery date with the supplier before ordering.
The listed speed is 6450 rpm. Confirm frequency, control method, and duty point for the installed system.
Verify supply, wiring, obstructions, impeller movement, and protection status. Use the model datasheet before replacement or repair.

GF40282B3-10000-QDP addresses servers and data-center electronics through a 24 VDC DC axial fan platform measuring 40 × 40 × 28 mm. 10500 W input is the defining electrical load in the supplied data. Use the documented cooling output when planning cooling-margin review. Check the full suffix before confirming connector details.
Read More
Applied in servers and data-center electronics, SUNON GF40282B2-10000-QDP is a 24 VDC DC axial fan in a 40 × 40 × 28 mm frame. 13100 W input is the defining electrical load in the supplied data. During cooling-margin review, compare the model's acoustic value. Check the full suffix before confirming connector details.
Read More
For thermal management in servers and data-center electronics, the GF40282B1-10000-QDP provides a 24 VDC DC axial fan configuration measuring 40 × 40 × 28 mm. 14600 W input is the defining electrical load in the supplied data. Review its application data during cabinet ventilation planning. Verify bearing and signal options in the exact datasheet.
Read More
Within servers and data-center electronics, SUNON GF40282B3-10000-SDP serves as a 40 × 40 × 28 mm DC axial fan operating at 24 VDC. 10500 W input is the defining electrical load in the supplied data. For cooling-margin review, start with the supplied frame geometry. Check the full suffix before confirming connector details.
Read More
The GF40282B3-10000-AEP is SUNON's 24 VDC, 40 × 40 × 28 mm DC axial fan option for servers and data-center electronics. Its 500 rpm rating defines a lower-speed operating point. Review its operating point during cooling-margin review. Check the full suffix before confirming connector details.
Read More
SUNON configures GF40282B3-10000-ADP as a 40 × 40 × 28 mm DC axial fan for servers and data-center electronics, operating at 24 VDC. Its 500 rpm rating defines a lower-speed operating point. Treat the pressure capability as a primary input to cooling-margin review. Check the full suffix before confirming connector details.
Read More