For ventilation needs in servers and data-center electronics, the GF80251B3-000U-AC9 provides a 12 VDC DC axial fan configuration measuring 80 × 80 × 25 mm. Up to 90 m³/h is its most prominent listed performance figure. Review its sound level during thermal validation. Review connector, alarm, and sensor options separately.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 80x80x25mm |
| Max.Air Flow(m³/h) | 90 |
| Max.Pressure(Pa) | 74.7 |
| Input Power(W) | 2.4 |
| Speed(rpm) | 4200 |
| Noise(db) | 44.5 |
SUNON GF80251B3-000U-AC9 brings active air movement to industrial equipment. This DC brushless axial fan helps equipment designers control thermal conditions around densely arranged parts.
The 90 m3/h airflow rating indicates the available cooling-air volume before system losses. Fan-curve review is needed to confirm delivery inside the finished equipment. The matching document lists IP56 protection, providing a defined basis for environmental exposure review.
For GF80251B3-000U-AC9 integration, prioritize inlet clearance. Include prototype trials in engineering approval, and confirm the full model interface before ordering. This supports reliable cooling and traceable purchasing. Keep the intake free from nearby walls or bundled wiring.
Verify supply, wiring, obstructions, impeller movement, and protection status. Use the model datasheet before replacement or repair.
Yes. The worksheet lists up to 74.7 Pa; compare it with the system curve.
Review its 80 × 80 × 25 mm size, 90 m³/h airflow, 74.7 Pa pressure, system resistance, and available mounting space.
It is listed for servers and data-center electronics. Check dimensions, airflow, pressure, and the installation environment against the actual equipment.
The supplied row does not state the connector or lead configuration. Follow the model-specific wiring drawing.

Within servers and data-center electronics, SUNON GF40282B3-10000-SDP serves as a 40 × 40 × 28 mm DC axial fan operating at 24 VDC. 10500 W input is the defining electrical load in the supplied data. For cooling-margin review, start with the supplied frame geometry. Check the full suffix before confirming connector details.
Read More
GF40282B3-10000-QDP addresses servers and data-center electronics through a 24 VDC DC axial fan platform measuring 40 × 40 × 28 mm. 10500 W input is the defining electrical load in the supplied data. Use the documented cooling output when planning cooling-margin review. Check the full suffix before confirming connector details.
Read More
The GF40282B3-10000-AEP is SUNON's 24 VDC, 40 × 40 × 28 mm DC axial fan option for servers and data-center electronics. Its 500 rpm rating defines a lower-speed operating point. Review its operating point during cooling-margin review. Check the full suffix before confirming connector details.
Read More
SUNON configures GF40282B3-10000-ADP as a 40 × 40 × 28 mm DC axial fan for servers and data-center electronics, operating at 24 VDC. Its 500 rpm rating defines a lower-speed operating point. Treat the pressure capability as a primary input to cooling-margin review. Check the full suffix before confirming connector details.
Read More
SUNON GF40282B2-10000-SDP combines a 40 × 40 × 28 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. 13100 W input is the defining electrical load in the supplied data. Base cooling-margin review on the stated dimensional envelope. Check the full suffix before confirming connector details.
Read More
Applied in servers and data-center electronics, SUNON GF40282B2-10000-QDP is a 24 VDC DC axial fan in a 40 × 40 × 28 mm frame. 13100 W input is the defining electrical load in the supplied data. During cooling-margin review, compare the model's acoustic value. Check the full suffix before confirming connector details.
Read More