SUNON GF80382B1-10000-SDP combines a 40 × 40 × 28 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. 8000 W input is the defining electrical load in the supplied data. For fan selection, start with the supplied technical profile. Use current model documentation to validate protection choices.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 40x40x28mm |
| Max.Air Flow(m³/h) | 182.3 |
| Max.Pressure(Pa) | 284 |
| Input Power(W) | 8000 |
| Speed(rpm) | 8000 |
| Noise(db) | 59.6 |
Designed for industrial equipment, the SUNON GF80382B1-10000-SDP provides DC brushless axial fan cooling in a format suited to equipment integration. It helps limit local heat buildup during operation.
The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market. Correct airflow direction and inlet clearance help translate the documented operating point into reliable equipment-level cooling.
Design approval for GF80382B1-10000-SDP should cover cable routing together with thermal-load testing during sourcing review. This creates a practical link between thermal validation, purchasing documentation and future servicing. Compare installed temperatures at representative equipment loads.
Confirm any missing bearing, connector, control, IP rating, life, certification, and performance-curve details for the complete part number.
Match voltage, dimensions, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.
Stock and lead time can change. Confirm the exact suffix, quantity, and delivery date with the supplier before ordering.
The listed speed is 8000 rpm. Confirm frequency, control method, and duty point for the installed system.
The worksheet lists up to 182.3 m³/h. Verify the operating point against system resistance.
Yes. The worksheet lists up to 284 Pa; compare it with the system curve.

Within servers and data-center electronics, SUNON GF40282B3-10000-SDP serves as a 40 × 40 × 28 mm DC axial fan operating at 24 VDC. 10500 W input is the defining electrical load in the supplied data. For cooling-margin review, start with the supplied frame geometry. Check the full suffix before confirming connector details.
Read More
SUNON GF40282B2-10000-SDP combines a 40 × 40 × 28 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. 13100 W input is the defining electrical load in the supplied data. Base cooling-margin review on the stated dimensional envelope. Check the full suffix before confirming connector details.
Read More
The GF40282B1-10000-SDP is SUNON's 24 VDC, 40 × 40 × 28 mm DC axial fan option for servers and data-center electronics. 14600 W input is the defining electrical load in the supplied data. Use the documented airflow profile when planning cooling-margin review. Check the full suffix before confirming connector details.
Read More
GF40282B3-10000-QDP addresses servers and data-center electronics through a 24 VDC DC axial fan platform measuring 40 × 40 × 28 mm. 10500 W input is the defining electrical load in the supplied data. Use the documented cooling output when planning cooling-margin review. Check the full suffix before confirming connector details.
Read More
The GF40282B3-10000-AEP is SUNON's 24 VDC, 40 × 40 × 28 mm DC axial fan option for servers and data-center electronics. Its 500 rpm rating defines a lower-speed operating point. Review its operating point during cooling-margin review. Check the full suffix before confirming connector details.
Read More
SUNON configures GF40282B3-10000-ADP as a 40 × 40 × 28 mm DC axial fan for servers and data-center electronics, operating at 24 VDC. Its 500 rpm rating defines a lower-speed operating point. Treat the pressure capability as a primary input to cooling-margin review. Check the full suffix before confirming connector details.
Read More