Get Quote
Home > Products > By type > Axial Fans > GF92251B2-0000-AC9 | SUNON 12V 3.6W 92x92x25mm 118.9m3/h DC Axial Fan for Data Center Cooling

GF92251B2-0000-AC9 SUNON Axial Fan

Brand :
SUNON
Model:
GF92251B2-0000-AC9 | SUNON 12V 3.6W 92x92x25mm 118.9m3/h DC Axial Fan for Data Center Cooling
Type:
Axial Fans
Industry:
Data Center Cooling
Description:

For thermal management in servers and data-center electronics, the GF92251B2-0000-AC9 provides a 12 VDC DC axial fan configuration measuring 92 × 92 × 25 mm. Up to 118.9 m³/h is its most prominent listed performance figure. For spares assessment, start with the supplied pressure capability. Confirm control inputs against the complete ordering code.

Datasheet:
GF92251B2-0000-AC9 | SUNON 12V 3.6W 92x92x25mm 118.9m3/h DC Axial Fan for Data Center Cooling Datasheet (Pdf)

Product Features

Rated Voltage(V)12
Size(mm)92x92x25mm
Max.Air Flow(m³/h)118.9
Max.Pressure(Pa)74.7
Input Power(W)3.6
Speed(rpm)4200
Noise(db)45

Product Features

Reliable Fan Cooling

SUNON GF92251B2-0000-AC9 is a DC brushless axial fan for server and data-center equipment. It establishes forced airflow where passive cooling cannot adequately protect heat-producing assemblies.

The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market. Correct airflow direction and inlet clearance help translate the documented operating point into reliable equipment-level cooling.

A dependable GF92251B2-0000-AC9 installation starts with a review of exhaust separation. Complete acoustic evaluation during sourcing review to confirm compatibility, operating margin and the information needed for repeat orders. Separate discharge air from the intake path inside the finished enclosure.

Application Industry

Frequently Asked Questions

How can GF92251B2-0000-AC9 affect operating cost?

Compare its listed 3.6 W input with the required airflow and run time. Total savings depend on the complete system duty point.

What noise data are available for GF92251B2-0000-AC9?

The worksheet lists 45 dB. Installation distance, airflow resistance, and enclosure acoustics can change the measured result.

What should be checked if GF92251B2-0000-AC9 stops?

Verify supply, wiring, obstructions, impeller movement, and protection status. Use the model datasheet before replacement or repair.

What bearing information is confirmed for GF92251B2-0000-AC9?

The exact bearing option is not confirmed by the row-level data. Check the complete suffix in the current SUNON specification.

Which performance figures define GF92251B2-0000-AC9?

Use the listed voltage, size, 118.9 m³/h airflow, 4200 rpm, and 3.6 W input for preliminary comparison.