For airflow duties across servers and data-center electronics, the GF92382B1-10000-SDP provides a 24 VDC DC axial fan configuration measuring 40 × 40 × 28 mm. 7200 W input is the defining electrical load in the supplied data. Treat the rated dataset as a primary input to spares assessment. Confirm control inputs against the complete ordering code.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 40x40x28mm |
| Max.Air Flow(m³/h) | 246.9 |
| Max.Pressure(Pa) | 298.9 |
| Input Power(W) | 7200 |
| Speed(rpm) | 7200 |
| Noise(db) | 60.6 |
The SUNON GF92382B1-10000-SDP positions a DC brushless axial fan for industrial equipment. Its airflow path supports heat removal from enclosed components and toward the equipment exhaust.
The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market. Correct airflow direction and inlet clearance help translate the documented operating point into reliable equipment-level cooling.
OEM teams specifying GF92382B1-10000-SDP should check airflow direction and complete power-budget review during sourcing review. A documented interface review helps purchasing teams control fit, cooling continuity and replacement planning. Verify orientation so heated air does not recirculate through the inlet.
The workbook marks the product as RoHS compliant. Confirm UL, TUV, VDE, or other project-specific approvals for the exact suffix.
Confirm any missing bearing, connector, control, IP rating, life, certification, and performance-curve details for the complete part number.
Inspect for dust, blocked airflow, abnormal noise, loose mounting, and wiring damage. Isolate power before cleaning or service.
Stock and lead time can change. Confirm the exact suffix, quantity, and delivery date with the supplier before ordering.
The listed rating is 24 VDC. Verify polarity or mains frequency, wiring, and protection before commissioning.

Within servers and data-center electronics, SUNON GF40282B3-10000-SDP serves as a 40 × 40 × 28 mm DC axial fan operating at 24 VDC. 10500 W input is the defining electrical load in the supplied data. For cooling-margin review, start with the supplied frame geometry. Check the full suffix before confirming connector details.
Read More
SUNON GF40282B2-10000-SDP combines a 40 × 40 × 28 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. 13100 W input is the defining electrical load in the supplied data. Base cooling-margin review on the stated dimensional envelope. Check the full suffix before confirming connector details.
Read More
The GF40282B1-10000-SDP is SUNON's 24 VDC, 40 × 40 × 28 mm DC axial fan option for servers and data-center electronics. 14600 W input is the defining electrical load in the supplied data. Use the documented airflow profile when planning cooling-margin review. Check the full suffix before confirming connector details.
Read More
GF40282B3-10000-QDP addresses servers and data-center electronics through a 24 VDC DC axial fan platform measuring 40 × 40 × 28 mm. 10500 W input is the defining electrical load in the supplied data. Use the documented cooling output when planning cooling-margin review. Check the full suffix before confirming connector details.
Read More
The GF40282B3-10000-AEP is SUNON's 24 VDC, 40 × 40 × 28 mm DC axial fan option for servers and data-center electronics. Its 500 rpm rating defines a lower-speed operating point. Review its operating point during cooling-margin review. Check the full suffix before confirming connector details.
Read More
SUNON configures GF40282B3-10000-ADP as a 40 × 40 × 28 mm DC axial fan for servers and data-center electronics, operating at 24 VDC. Its 500 rpm rating defines a lower-speed operating point. Treat the pressure capability as a primary input to cooling-margin review. Check the full suffix before confirming connector details.
Read More