| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() A4D350-AN08-01 | ebm-papst 400V 230W AC Axial Fan for HVAC/R The A4D350-AN08-01 from ebm-papst combines 400 V operation with an AC axial fan configuration for hvac/r. Its documented 3760 m³/h airflow, 90 Pa pressure, 1520 RPM helps engineers compare the fan with the system resistance, installation space and cooling demand. |
400 | 350 | 3760 | 90 | 230 | 1520 | 58 | |
![]() A4D450-AU01-01 | ebm-papst 400V 415W AC Axial Fan for HVAC/R Designed as an AC axial fan, the ebm-papst A4D450-AU01-01 operates at 400 V for hvac/r. With 6085 m³/h airflow, 85 Pa pressure, 1360 RPM, it provides directed airflow for space-conscious equipment and thermal-management assemblies. |
400 | 450 | 6085 | 85 | 415 | 1360 | - | |
![]() A4D400-AP12-16 | ebm-papst 400V 185W AC Axial Fan for HVAC/R The ebm-papst A4D400-AP12-16 is a 400 V AC axial fan developed for hvac/r. Its listed performance—4615 m³/h airflow, 120 Pa pressure, 1690 RPM—supports stable heat removal and dependable operation when matched to the required duty point. |
400 | 400 | 4615 | 120 | 185 | 1690 | 69 | |
![]() A4D400-AP12-02 | ebm-papst 400V 185W AC Axial Fan for HVAC/R A 400 V AC axial fan for hvac/r, the ebm-papst A4D400-AP12-02 delivers model-specific cooling performance. Its 4615 m³/h airflow, 120 Pa pressure, 1690 RPM supports efficient ventilation where reliable airflow and compact integration are important. |
400 | 400 | 4615 | 120 | 185 | 1690 | - | |
![]() A4D400-AP12-01 | ebm-papst 400V 185W AC Axial Fan for HVAC/R The ebm-papst A4D400-AP12-01, a 400 V AC axial fan, is intended for hvac/r. Listed performance includes 4615 m³/h airflow, 120 Pa pressure, 1690 RPM, giving designers a clear basis for checking airflow, mounting and electrical compatibility. |
400 | 400 | 4615 | 120 | 185 | 1690 | 69 | |
![]() A4D300-AS34-06 | ebm-papst 400V 90W AC Axial Fan for HVAC/R Built for hvac/r, the ebm-papst A4D300-AS34-06 is a 400 V AC axial fan. Its combination of 1905 m³/h airflow, 68 Pa pressure, 1400 RPM is intended to maintain controlled airflow and reduce thermal stress in demanding installations. |
400 | 300 | 1905 | 68 | 90 | 1400 | 58 | |
A4D500-AD03-01 | ebm-papst 480V 1220W AC Axial Fan for HVAC/R ebm-papst A4D500-AD03-01 is specified as an AC axial fan using a 480 V supply, suited to hvac/r. The available rating of 11300 m³/h airflow, 150 Pa pressure, 1570 RPM enables model-specific airflow matching in OEM equipment and maintenance replacements. |
480 | 500 | 11300 | 150 | 1220 | 1570 | 75 | |
![]() A4D350-AP08-16 | ebm-papst 400V 130W AC Axial Fan for HVAC/R For hvac/r, the ebm-papst A4D350-AP08-16 provides a 400 V AC axial fan solution. Performance data of 3280 m³/h airflow, 90 Pa pressure, 1410 RPM supports practical selection for continuous ventilation, component cooling and replacement planning. |
400 | 350 | 3280 | 90 | 130 | 1410 | - | |
![]() A4D400-AP12-15 | ebm-papst 230V 135W AC Axial Fan for HVAC/R The A4D400-AP12-15 from ebm-papst combines 230 V operation with an AC axial fan configuration for hvac/r. Its documented 4000 m³/h airflow, 100 Pa pressure, 1450 RPM helps engineers compare the fan with the system resistance, installation space and cooling demand. |
230 | 400 | 4000 | 100 | 135 | 1450 | 65 | |
![]() A4D350-AN08-13 | ebm-papst 400V 230W AC Axial Fan for HVAC/R Designed as an AC axial fan, the ebm-papst A4D350-AN08-13 operates at 400 V for hvac/r. With 3760 m³/h airflow, 90 Pa pressure, 1520 RPM, it provides directed airflow for space-conscious equipment and thermal-management assemblies. |
400 | 350 | 3760 | 90 | 230 | 1520 | 58 | |
![]() A4D300-AS34-01 | ebm-papst 400V 90W AC Axial Fan for HVAC/R The ebm-papst A4D300-AS34-01 is a 400 V AC axial fan developed for hvac/r. Its listed performance—1905 m³/h airflow, 70 Pa pressure, 1400 RPM—supports stable heat removal and dependable operation when matched to the required duty point. |
400 | 300 | 1905 | 70 | 90 | 1400 | 60 | |
![]() A4D500-AM01-03 | ebm-papst 400V 950W AC Axial Fan for HVAC/R A 400 V AC axial fan for hvac/r, the ebm-papst A4D500-AM01-03 delivers model-specific cooling performance. Its 10830 m³/h airflow, 145 Pa pressure, 1510 RPM supports efficient ventilation where reliable airflow and compact integration are important. |
400 | 500 | 10830 | 145 | 950 | 1510 | 57 | |
![]() A4D710-AF01-02 | ebm-papst 400V 2380W AC Axial Fan for Refrigeration The ebm-papst A4D710-AF01-02, a 400 V AC axial fan, is intended for refrigeration and cooling equipment. Listed performance includes 20745 m³/h airflow, 250 Pa pressure, 1350 RPM, giving designers a clear basis for checking airflow, mounting and electrical compatibility. |
400 | 710 | 20745 | 250 | 2380 | 1350 | 73 | |
![]() A4D710-AF01-01 | ebm-papst 400V 2380W AC Axial Fan for Refrigeration Built for refrigeration and cooling equipment, the ebm-papst A4D710-AF01-01 is a 400 V AC axial fan. Its combination of 12930 m³/h airflow, 250 Pa pressure, 1350 RPM is intended to maintain controlled airflow and reduce thermal stress in demanding installations. |
400 | 710 | 12930 | 250 | 2380 | 1350 | 71 | |
![]() A4D630-AR01-02 | ebm-papst 400/480V 1250W AC Axial Fan for Refrigeration ebm-papst A4D630-AR01-02 is specified as an AC axial fan using a 480 V supply, suited to refrigeration and cooling equipment. The available rating of 13830 m³/h airflow, 150 Pa pressure, 1395 RPM enables model-specific airflow matching in OEM equipment and maintenance replacements. |
400/480 | 630 | 13830 | 150 | 1250 | 1395 | 79 | |
![]() A4D630-AR01-01 | ebm-papst 400V 1250W AC Axial Fan for Refrigeration For refrigeration and cooling equipment, the ebm-papst A4D630-AR01-01 provides a 400 V AC axial fan solution. Performance data of 13830 m³/h airflow, 150 Pa pressure, 1395 RPM supports practical selection for continuous ventilation, component cooling and replacement planning. |
400 | 630 | 13830 | 150 | 1250 | 1395 | 79 | |
![]() A4D630-AF03-03 | ebm-papst 400V 2860W AC Axial Fan for Refrigeration The A4D630-AF03-03 from ebm-papst combines 400 V operation with an AC axial fan configuration for refrigeration and cooling equipment. Its documented 18830 m³/h airflow, 310 Pa pressure, 1715 RPM helps engineers compare the fan with the system resistance, installation space and cooling demand. |
400 | 630 | 18830 | 310 | 2860 | 1715 | 86 | |
![]() A4D630-AD01-01 | ebm-papst 400V 2630W AC Axial Fan for Refrigeration Designed as an AC axial fan, the ebm-papst A4D630-AD01-01 operates at 400 V for refrigeration and cooling equipment. With 19890 m³/h airflow, 220 Pa pressure, 1375 RPM, it provides directed airflow for space-conscious equipment and thermal-management assemblies. |
400 | 630 | 19890 | 220 | 2630 | 1375 | 80 | |
![]() A4D630-AH01-02 | ebm-papst 400V 1970W AC Axial Fan for Refrigeration The ebm-papst A4D630-AH01-02 is a 400 V AC axial fan developed for refrigeration and cooling equipment. Its listed performance—1310 RPM—supports stable heat removal and dependable operation when matched to the required duty point. |
400 | 630 | - | - | 1970 | 1310 | - | |
![]() A4D560-AQ01-02 | ebm-papst 400V 1110W AC Axial Fan for Refrigeration A 400 V AC axial fan for refrigeration and cooling equipment, the ebm-papst A4D560-AQ01-02 delivers model-specific cooling performance. Its 11975 m³/h airflow, 170 Pa pressure, 1350 RPM supports efficient ventilation where reliable airflow and compact integration are important. |
400 | 560 | 11975 | 170 | 1110 | 1350 | 70 |
Choosing the right AC Axial starts with the operating point rather than the model name. Define the airflow you actually need in CFM or m³/h and the static pressure the fan must overcome, then look for units whose performance curves pass through that point with a safety margin instead of sitting at the edge of the curve.
Pay attention to the electrical details early. DC fans typically run on 12/24/48 V and integrate easily with control boards, while AC fans suit 115/230 V fixed-speed installations. If the airflow must change with load, choose EC technology with PWM or analog control and, where monitoring matters, a tachometer output so the controller can detect fan failure.
Environment and compliance come next. Match the IP rating to dust and moisture exposure, prefer ball bearings wherever the fan runs hot, vertically or around the clock, and confirm certifications — UL, CE, RoHS — against your destination market. Setting the acoustic limit in dBA early prevents late-stage redesign when the first unit proves too loud.
Finally, compare candidates on total delivery risk, not only on price: confirm stock for the quantity you need, check the lead time for the next batch, and ask for datasheets and dimension drawings before committing. Our team cross-checks curves, dimensions and electrical data for you before quotation There are currently 531 items in this category ready to compare.
AC Axial appear in almost every sector where heat or stale air must be moved reliably. Typical environments include server rooms and data centers, refrigeration condensers and cold-store evaporators, HVAC air handling units, telecom cabinets, medical and laboratory equipment, welding and CNC machine enclosures, and renewable-energy power cabinets. In each of these settings the fan is a critical component: its failure stops production, damages stored goods or forces expensive emergency downtime.
One recurring scenario comes from control cabinet retrofits: the original fan is obsolete, the mounting hole pattern cannot change, and downtime is measured in hours. We match the old unit against current series by frame size, airflow and noise, propose the closest drop-in alternative, and ship with a datasheet that lets the electrician connect it without redesign.
For cold storage operators the pain is simple: a failed evaporator or condenser fan must be replaced now, not after a six-week import cycle. Matching blade diameter, speed and protection class against stocked equivalents lets us restore cooling capacity within days, which is why replacement supply has become a core part of this category for us.
Whether the project involves new equipment or the replacement of installed ebmpapst units, the workflow is the same: send us the operating point and constraints, and we return a validated selection with datasheets, curves and a clear lead time.
Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.
Every unit is covered by the manufacturer's warranty against defects in materials and workmanship, and we support you through the whole claim process so you deal with one supplier instead of chasing a factory overseas. If a failure appears in service, send us the serial number, operating conditions and photos, and we will arrange the replacement or credit path agreed in the quotation.
Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.