| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() MF50201V2-1B000-A99 | SUNON 12V 1.2W 50x50x20mm DC Centrifugal Blower for Telecommunications A 50 × 50 × 20 mm frame and 12 VDC rating define MF50201V2-1B000-A99, a DC blower for telecom cabinets and network equipment. Its 8.7 m³/h airflow rating suits the stated equipment-cooling role. Review its system interface during duty-point matching. Validate approvals and protection at complete-part-number level. |
12 | 50x50x20mm | 8.7 | 114.6 | 1.2 | 4650 | 30 | |
![]() MF50201V1-1B000-A99 | SUNON 12V 1.49W 50x50x20mm DC Centrifugal Blower for Telecommunications The MF50201V1-1B000-A99 is SUNON's 12 VDC, 50 × 50 × 20 mm DC blower option for telecom cabinets and network equipment. Its 9.9 m³/h airflow rating suits the stated equipment-cooling role. Treat the cooling specification as a primary input to duty-point matching. Validate approvals and protection at complete-part-number level. |
12 | 50x50x20mm | 9.9 | 164.4 | 1.49 | 5300 | 34.8 | |
![]() MF50151VX-1B000-A99 | SUNON 12V 1.86W 50x50x15mm 9.2m3/h DC Centrifugal Blower for New Energy Sized for inverters, energy-storage systems, and charging equipment, SUNON MF50151VX-1B000-A99 is a 12 VDC DC blower in a 50 × 50 × 15 mm frame. Its 9.2 m³/h airflow rating suits the stated equipment-cooling role. The recorded selection parameters should guide duty-point matching. Validate approvals and protection at complete-part-number level. |
12 | 50x50x15mm | 9.2 | 241.6 | 1.86 | 6200 | 42.2 | |
![]() MF50151V3-1B000-A99 | SUNON 12V 0.36W 50x50x15mm DC Centrifugal Blower for Telecommunications SUNON MF50151V3-1B000-A99 is a 12 VDC DC blower in a 50 × 50 × 15 mm format for telecom cabinets and network equipment. A listed input of 0.36 W is the model's notable electrical characteristic. Use the documented motor input when planning duty-point matching. Validate approvals and protection at complete-part-number level. |
12 | 50x50x15mm | 4.6 | 44.8 | 0.36 | 3200 | 23.2 | |
![]() MF50151V2-1B000-A99 | SUNON 12V 0.54W 50x50x15mm DC Centrifugal Blower for Telecommunications The 50 × 50 × 15 mm MF50151V2-1B000-A99 brings 12 VDC DC blower cooling to telecom cabinets and network equipment. Its 5.9 m³/h airflow rating suits the stated equipment-cooling role. Treat the equipment fit as a primary input to duty-point matching. Validate approvals and protection at complete-part-number level. |
12 | 50x50x15mm | 5.9 | 99.6 | 0.54 | 4200 | 32.6 | |
![]() MF50151V1-1B000-A99 | SUNON 12V 1.14W 50x50x15mm DC Centrifugal Blower for Telecommunications Designed for telecom cabinets and network equipment, SUNON MF50151V1-1B000-A99 is a 12 VDC DC blower in a 50 × 50 × 15 mm frame. Its 7.6 m³/h airflow rating suits the stated equipment-cooling role. During duty-point matching, compare the model's catalog specification. Validate approvals and protection at complete-part-number level. |
12 | 50x50x15mm | 7.6 | 166.9 | 1.14 | 5200 | 39.6 | |
![]() PMB1297PYB1-AY | SUNON 12V 8.6W 97.2x94.4x33mm DC Centrifugal Blower for Industrial Cooling Engineered for industrial electronics and equipment cooling, SUNON PMB1297PYB1-AY is a 12 VDC DC blower in a 97.2 × 94.4 × 33 mm frame. 229.2 Pa maximum pressure is the standout documented duty-point value. Base procurement comparison on the stated catalog specification. Use the latest specification for frequency and tolerance limits. |
12 | 97.2 *94.4*33 | 51.85 | 229.2 | 8.6 | 3600 | 55.8 | |
![]() PF75302B1-1B00U-Q99 | SUNON 24V 2.76W 75x75x30mm DC Centrifugal Blower for Industrial Cooling Applied in servers and data-center electronics, SUNON PF75302B1-1B00U-Q99 is a 24 VDC DC blower in a 75 × 75 × 30 mm frame. Its 26.35 m³/h airflow rating suits the stated equipment-cooling role. For thermal validation, start with the supplied cooling specification. Review connector, alarm, and sensor options separately. |
24 | 75x75x30mm | 26.35 | - | 2.76 | 3400 | 42 | |
![]() PF75302B3-L03C-Q99 | SUNON 24V 1.13W 75x75x30mm DC Centrifugal Blower for Industrial Cooling Equipment designers working with servers and data-center electronics can evaluate SUNON PF75302B3-L03C-Q99, a DC blower rated at 24 VDC and sized 75 × 75 × 30 mm. Its 2400 rpm rating defines a lower-speed operating point. The recorded cooling output should guide thermal validation. Review connector, alarm, and sensor options separately. |
24 | 75x75x30mm | 18.3 | 59.8 | 1.13 | 2400 | 32.9 | |
![]() EF50151BX-1L02C-S99 | SUNON 12V 1.8W 50x50x15mm DC Centrifugal Blower for Industrial Cooling Within telecom cabinets, base stations, and network equipment, EF50151BX-1L02C-S99 provides a 50 × 50 × 15 mm, 12 VDC DC blower configuration. Its 9.2 m³/h airflow rating suits the stated equipment-cooling role. For wiring review, start with the supplied dimensional envelope. Confirm environmental protection for the ordered version. |
12 | 50x50x15mm | 9.2 | 241.6 | 1.8 | 6200 | 45.8 | |
![]() GB1205PKV1-8AY | SUNON 12V 1.5W 50x50x20mm 9.7m3/h DC Centrifugal Blower for Industrial Cooling Built around industrial electronics and equipment cooling, SUNON GB1205PKV1-8AY is a 12 VDC DC blower in a 50 × 50 × 20 mm frame. Its 9.7 m³/h airflow rating suits the stated equipment-cooling role. Base wiring review on the stated airflow profile. Confirm environmental protection for the ordered version. |
12 | 50x50x20mm | 9.7 | 164.4 | 1.5 | 5200 | 35 | |
![]() PF75302B3-L03C-S99 | SUNON 24V 1.13W 75x75x30mm DC Centrifugal Blower for Industrial Cooling For ventilation needs in servers and data-center electronics, the PF75302B3-L03C-S99 provides a 24 VDC DC blower configuration measuring 75 × 75 × 30 mm. Its 2400 rpm rating defines a lower-speed operating point. Use the documented product configuration when planning controller selection. Treat bearing and life data as suffix-specific. |
24 | 75x75x30mm | 18.3 | 59.8 | 1.13 | 2400 | 32.9 | |
![]() MF50201V1-1Q030-S99 | SUNON 12V 1.49W 50x50x20mm DC Centrifugal Blower for Data Center Cooling Configured for servers and data-center electronics, SUNON MF50201V1-1Q030-S99 is a 12 VDC DC blower in a 50 × 50 × 20 mm frame. Its 9.9 m³/h airflow rating suits the stated equipment-cooling role. Treat the cooling specification as a primary input to controller selection. Treat bearing and life data as suffix-specific. |
12 | 50x50x20mm | 9.9 | 164.4 | 1.49 | 5300 | 34.8 | |
![]() PF97331BX-000U-S99 | SUNON 12V 42W 97x95x33mm DC Centrifugal Blower for Industrial Cooling SUNON PF97331BX-000U-S99 combines a 97 × 95 × 33 mm DC blower platform with a 12 VDC rating for servers and data-center electronics. 1300.2 Pa maximum pressure is the standout documented duty-point value. The recorded rotational rating should guide controller selection. Treat bearing and life data as suffix-specific. |
12 | 97x95x33mm | 92.9 | 1300.2 | 42 | 6800 | 63.2 | |
![]() EF50151B1-C03C-A99 | SUNON 12V 1.28W 50x50x15mm DC Centrifugal Blower for Industrial Cooling The EF50151B1-C03C-A99 is SUNON's 12 VDC, 50 × 50 × 15 mm DC blower option for telecom cabinets, base stations, and network equipment. Its 7.6 m³/h airflow rating suits the stated equipment-cooling role. Treat the operating point as a primary input to controller selection. Treat bearing and life data as suffix-specific. |
12 | 50x50x15mm | 7.6 | 166.9 | 1.28 | 5200 | 41 | |
![]() EF50151B1-C05C-A99 | SUNON 12V 1.28W 50x50x15mm DC Centrifugal Blower for Industrial Cooling Specified at 12 VDC, EF50151B1-C05C-A99 is a SUNON DC blower for telecom cabinets, base stations, and network equipment in 50 × 50 × 15 mm dimensions. Its 7.6 m³/h airflow rating suits the stated equipment-cooling role. Treat the application data as a primary input to mounting verification. Validate mounting and wiring from the model drawing. |
12 | 50x50x15mm | 7.6 | 166.9 | 1.28 | 5200 | 41 | |
![]() PF97331BX-B00U-S99 | SUNON 12V 4.2W 97x95x33mm DC Centrifugal Blower for Industrial Cooling Applied in servers and data-center electronics, SUNON PF97331BX-B00U-S99 is a 12 VDC DC blower in a 97 × 95 × 33 mm frame. 1300.2 Pa maximum pressure is the standout documented duty-point value. During mounting verification, compare the model's model record. Validate mounting and wiring from the model drawing. |
12 | 97x95x33mm | - | 1300.2 | 4.2 | 6800 | - | |
![]() EF50151BX-1C02C-S99 | SUNON 12V 1.8W 50x50x15mm DC Centrifugal Blower for Industrial Cooling The 12 VDC SUNON EF50151BX-1C02C-S99 is a DC blower sized 50 × 50 × 15 mm for telecom cabinets, base stations, and network equipment. Its 9.2 m³/h airflow rating suits the stated equipment-cooling role. Treat the installation footprint as a primary input to mounting verification. Validate mounting and wiring from the model drawing. |
12 | 50x50x15mm | 9.2 | 241.6 | 1.8 | 6200 | 45.8 | |
![]() EF50151B1-Q07A-A99 | SUNON 12V 1.28W 50x50x15mm DC Centrifugal Blower for Industrial Cooling SUNON EF50151B1-Q07A-A99 combines a 50 × 50 × 15 mm DC blower platform with a 12 VDC rating for telecom cabinets, base stations, and network equipment. Its 7.6 m³/h airflow rating suits the stated equipment-cooling role. Review its suffix definition during mounting verification. Validate mounting and wiring from the model drawing. |
12 | 50x50x15mm | 7.6 | 166.9 | 1.28 | 5200 | 41 | |
![]() EF50151BX-1C02C-A99 | SUNON 12V 1.8W 50x50x15mm DC Centrifugal Blower for Industrial Cooling The EF50151BX-1C02C-A99 is SUNON's 12 VDC, 50 × 50 × 15 mm DC blower option for telecom cabinets, base stations, and network equipment. Its 9.2 m³/h airflow rating suits the stated equipment-cooling role. The recorded mounting size should guide mounting verification. Validate mounting and wiring from the model drawing. |
12 | 50x50x15mm | 9.2 | 241.6 | 1.8 | 6200 | 45.8 |
The most reliable way to specify blower Fans is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.
Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.
Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.
End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 241 products are available in this category today.
The daily work of our sales engineers is built around blower Fans used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.
A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.
Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.
From one-piece emergency replacements to volume supply for equipment manufacturers, every enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.
Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.
Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 241 products in this category are listed online.
Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.