| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() 9BD12SC6-1 | Sanyo Denki 12VDC 3.36W DC Centrifugal Blower for medical equipment cooling The 76 × 76 × 20 mm Sanyo Denki 9BD12SC6-1 brings 12 VDC DC blower cooling to medical equipment cooling. Series options require suffix verification. Use the documented static-pressure entry when planning wiring review. Verify the exact bearing and signal options in the datasheet. Focus: spares strategy planning rated dataset. |
12 | 76*76*20 mm | 17.4 | 300 | 3.36 | 4500 | 43 | |
![]() 9BMB12P2G01 | Sanyo Denki 12VDC 21.6W DC Centrifugal Blower for medical equipment cooling For medical equipment cooling, 9BMB12P2G01 combines 12 VDC operation with a 97 × 97 × 33 mm DC blower design. Series options require suffix verification. 760 Pa maximum pressure is the most distinctive duty-point parameter. Check selection criteria review frame geometry. Focus: selection criteria review frame geometry. |
12 | 97*97*33 mm | 80.4 | 760 | 21.6 | 5750 | 61 | |
![]() 9BMB24P2KD03 | Sanyo Denki 24VDC 97x33mm DC Centrifugal Blower for medical equipment cooling For thermal management in medical equipment cooling, the 9BMB24P2KD03 provides a 24 VDC DC blower configuration measuring 97 × 33 mm. The 97 × 33 mm format is the primary stated selection detail. Use the documented cooling output when planning enclosure sizing. Check the full suffix before confirming connector details. |
24 | 97*33 | - | - | - | - | - | |
![]() 9BMB24P2K27 | Sanyo Denki 24VDC 97x33mm DC Centrifugal Blower for medical equipment cooling A 97 × 33 mm frame and 24 VDC rating define 9BMB24P2K27, a DC blower for medical equipment cooling. Series options require suffix verification. The 97 × 33 mm format is the primary stated selection detail. Check cooling margin validation mounting size. Focus: cooling margin validation mounting size. |
24 | 97*33 | - | - | - | - | - | |
![]() EF50151BX-1B000-A99 | SUNON 12V 1.8W 9.2m3/h DC Centrifugal Blower for Refrigeration Equipment Within telecom cabinets, base stations, and network equipment, SUNON EF50151BX-1B000-A99 serves as a 50 × 50 × 15 mm DC blower operating at 12 VDC. Its 9.2 m³/h airflow rating suits the stated equipment-cooling role. During airflow balancing, compare the model's duty-point values. Review connector, alarm, and sensor options separately. |
12 | 50x50x15mm | 9.2 | 241.6 | 1.8 | 6200 | 45.8 | |
![]() EF50151B3-1B000-A99 | SUNON 12V 0.44W 4.4m3/h DC Centrifugal Blower for Refrigeration Equipment The 12 VDC SUNON EF50151B3-1B000-A99 is a DC blower sized 50 × 50 × 15 mm for telecom cabinets, base stations, and network equipment. Its 4.4 m³/h airflow rating suits the stated equipment-cooling role. The recorded installation footprint should guide airflow balancing. Review connector, alarm, and sensor options separately. |
12 | 50x50x15mm | 4.4 | 44.8 | 0.44 | 3200 | 26 | |
![]() PF97331BX-B000-A99 | SUNON 12V 42W 97x95x33mm DC Centrifugal Blower for Data Center Cooling Applied in servers and data-center electronics, SUNON PF97331BX-B000-A99 is a 12 VDC DC blower in a 97 × 95 × 33 mm frame. 1300.2 Pa maximum pressure is the standout documented duty-point value. Review its model record during operating-cost analysis. Validate mounting and wiring from the model drawing. |
12 | 97x95x33mm | 92.9 | 1300.2 | 42 | 6800 | 63.2 | |
![]() PF97331B1-B000-A99 | SUNON 12V 19.2W 97x95x33mm DC Centrifugal Blower for Data Center Cooling Within servers and data-center electronics, SUNON PF97331B1-B000-A99 serves as a 97 × 95 × 33 mm DC blower operating at 12 VDC. 844.4 Pa maximum pressure is the standout documented duty-point value. Treat the product configuration as a primary input to operating-cost analysis. Validate mounting and wiring from the model drawing. |
12 | 97x95x33mm | 75.1 | 844.4 | 19.2 | 5400 | 58 | |
![]() PF75302B3-1B000-A99 | SUNON 24V 1.13W 75x75x30mm DC Centrifugal Blower for Data Center Cooling For ventilation needs in servers and data-center electronics, the PF75302B3-1B000-A99 provides a 24 VDC DC blower configuration measuring 75 × 75 × 30 mm. Its 2400 rpm rating defines a lower-speed operating point. For installation review, start with the supplied rated dataset. Obtain the applicable curve before final duty-point approval. |
24 | 75x75x30mm | 18.3 | 59.8 | 1.13 | 2400 | 32.9 | |
![]() PF75302B2-1B000-A99 | SUNON 24V 1.92W 75x75x30mm DC Centrifugal Blower for Data Center Cooling SUNON PF75302B2-1B000-A99 combines a 75 × 75 × 30 mm DC blower platform with a 24 VDC rating for servers and data-center electronics. Its 3000 rpm rating defines a lower-speed operating point. Use the documented motor input when planning installation review. Obtain the applicable curve before final duty-point approval. |
24 | 75x75x30mm | 23.4 | 107.1 | 1.92 | 3000 | 38.6 | |
![]() PF75302B1-1B000-A99 | SUNON 24V 2.76W 75x75x30mm DC Centrifugal Blower for Data Center Cooling Used in servers and data-center electronics, SUNON PF75302B1-1B000-A99 is a 24 VDC DC blower in a 75 × 75 × 30 mm frame. 142 Pa maximum pressure is the standout documented duty-point value. Review its ventilation capacity during installation review. Obtain the applicable curve before final duty-point approval. |
24 | 75x75x30mm | 26.3 | 142 | 2.76 | 3400 | 42 | |
![]() PF75301B3-1B000-A99 | SUNON 12V 0.99W 75x75x30mm DC Centrifugal Blower for Data Center Cooling Within servers and data-center electronics, SUNON PF75301B3-1B000-A99 serves as a 75 × 75 × 30 mm DC blower operating at 12 VDC. Its 2400 rpm rating defines a lower-speed operating point. Treat the equipment fit as a primary input to installation review. Obtain the applicable curve before final duty-point approval. |
12 | 75x75x30mm | 18.3 | 59.8 | 0.99 | 2400 | 32.9 | |
![]() PF75301B2-1B000-A99 | SUNON 12V 1.71W 75x75x30mm DC Centrifugal Blower for Data Center Cooling Equipment designers working with servers and data-center electronics can evaluate SUNON PF75301B2-1B000-A99, a DC blower rated at 12 VDC and sized 75 × 75 × 30 mm. Its 3000 rpm rating defines a lower-speed operating point. Base installation review on the stated suffix definition. Obtain the applicable curve before final duty-point approval. |
12 | 75x75x30mm | 23.4 | 107.1 | 1.71 | 3000 | 38.6 | |
![]() PF75301B1-1B000-A99 | SUNON 12V 2.4W 75x75x30mm DC Centrifugal Blower for Data Center Cooling The PF75301B1-1B000-A99 is SUNON's 12 VDC, 75 × 75 × 30 mm DC blower option for servers and data-center electronics. 142 Pa maximum pressure is the standout documented duty-point value. During installation review, compare the model's catalog specification. Obtain the applicable curve before final duty-point approval. |
12 | 75x75x30mm | 26.3 | 142 | 2.4 | 3400 | 42 | |
![]() PF97331BX-B000-S99 | SUNON 12V 42W 97x95x33mm DC Centrifugal Blower for Industrial Cooling Within servers and data-center electronics, PF97331BX-B000-S99 provides a 97 × 95 × 33 mm, 12 VDC DC blower configuration. 1300.2 Pa maximum pressure is the standout documented duty-point value. Treat the dimensional envelope as a primary input to design qualification. Match the exact part number before approving a substitute. |
12 | 97x95x33mm | 92.9 | 1300.2 | 42 | 6800 | 63.2 | |
![]() PF97331B1-B00U-S99 | SUNON 12V 19.2W 97x97x33mm DC Centrifugal Blower for Industrial Cooling Applied in servers and data-center electronics, SUNON PF97331B1-B00U-S99 is a 12 VDC DC blower in a 97 × 97 × 33 mm frame. 844.4 Pa maximum pressure is the standout documented duty-point value. For design qualification, start with the supplied airflow profile. Match the exact part number before approving a substitute. |
12 | 97x97x33mm | 75.14 | 844.4 | 19.2 | 5400 | 58 | |
![]() MF60151VX-1B000-A99 | SUNON 12V 1.56W 60x60x15mm DC Centrifugal Blower for Data Center Cooling The MF60151VX-1B000-A99 is SUNON's 12 VDC, 60 × 60 × 15 mm DC blower option for servers and data-center electronics. Its 10.5 m³/h airflow rating suits the stated equipment-cooling role. During equipment integration, compare the model's operating point. Request the exact performance curve for final engineering signoff. |
12 | 60x60x15mm | 10.5 | 176.9 | 1.56 | 4500 | 37.7 | |
![]() MF60151V2-1B000-A99 | SUNON 12V 0.66W 60x60x15mm DC Centrifugal Blower for Telecommunications Configured for telecom cabinets and network equipment, SUNON MF60151V2-1B000-A99 is a 12 VDC DC blower in a 60 × 60 × 15 mm frame. Its 8.7 m³/h airflow rating suits the stated equipment-cooling role. Use the documented acoustic value when planning equipment integration. Request the exact performance curve for final engineering signoff. |
12 | 60x60x15mm | 8.7 | 82.2 | 0.66 | 3600 | 29 | |
![]() MF60151V1-1B000-A99 | SUNON 12V 0.9W 60x60x15mm DC Centrifugal Blower for Telecommunications For telecom cabinets and network equipment, MF60151V1-1B000-A99 combines 12 VDC operation with a 60 × 60 × 15 mm DC blower design. Its 9.7 m³/h airflow rating suits the stated equipment-cooling role. Treat the speed benchmark as a primary input to equipment integration. Request the exact performance curve for final engineering signoff. |
12 | 60x60x15mm | 9.7 | 114.6 | 0.9 | 4000 | 32.8 | |
![]() MF50201V3-1B000-A99 | SUNON 12V 0.9W 50x50x20mm DC Centrifugal Blower for Telecommunications Within telecom cabinets and network equipment, SUNON MF50201V3-1B000-A99 serves as a 50 × 50 × 20 mm DC blower operating at 12 VDC. Its 8.2 m³/h airflow rating suits the stated equipment-cooling role. Use the documented product configuration when planning duty-point matching. Validate approvals and protection at complete-part-number level. |
12 | 50x50x20mm | 8.2 | 87.2 | 0.9 | 4350 | 27.5 |
The most reliable way to specify blower Fans is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.
Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.
Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.
End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 241 products are available in this category today.
The daily work of our sales engineers is built around blower Fans used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.
A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.
Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.
From one-piece emergency replacements to volume supply for equipment manufacturers, every enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.
Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.
Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 241 products in this category are listed online.
Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.