| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() EF50151B1-C02C-A99 | SUNON 12V 1.28W 50x50x15mm DC Centrifugal Blower for Industrial Cooling EF50151B1-C02C-A99 addresses telecom cabinets, base stations, and network equipment through a 12 VDC DC blower platform measuring 50 × 50 × 15 mm. Its 7.6 m³/h airflow rating suits the stated equipment-cooling role. Base airflow-path design on the stated product configuration. Obtain the applicable curve before final duty-point approval. |
12 | 50x50x15mm | 7.6 | 166.9 | 1.28 | 5200 | 41 | |
![]() EF50151B2-C03C-A99 | SUNON 12V 0.65W 50x50x15mm DC Centrifugal Blower for Industrial Cooling SUNON EF50151B2-C03C-A99 combines a 50 × 50 × 15 mm DC blower platform with a 12 VDC rating for telecom cabinets, base stations, and network equipment. Its 5.9 m³/h airflow rating suits the stated equipment-cooling role. During airflow-path design, compare the model's system interface. Obtain the applicable curve before final duty-point approval. |
12 | 50x50x15mm | 5.9 | 99.6 | 0.65 | 4200 | 34 | |
![]() MF50201V1-1B00U-G99 | SUNON 12V 1.49W 50x50x20mm DC Centrifugal Blower for Telecommunications Within telecom cabinets and network equipment, SUNON MF50201V1-1B00U-G99 serves as a 50 × 50 × 20 mm DC blower operating at 12 VDC. Its 9.9 m³/h airflow rating suits the stated equipment-cooling role. For airflow-path design, start with the supplied duty-point values. Obtain the applicable curve before final duty-point approval. |
12 | 50x50x20mm | 9.9 | 164.4 | 1.49 | 5300 | 34.8 | |
![]() PF75302B1-1B00U-G99 | SUNON 24V 2.76W 75x75x30mm DC Centrifugal Blower for Industrial Cooling The 24 VDC SUNON PF75302B1-1B00U-G99 is a DC blower sized 75 × 75 × 30 mm for servers and data-center electronics. Its 26.35 m³/h airflow rating suits the stated equipment-cooling role. Use the documented installation footprint when planning airflow-path design. Obtain the applicable curve before final duty-point approval. |
24 | 75x75x30mm | 26.35 | - | 2.76 | 3400 | 42 | |
![]() PF75301B2-1B00U-A99 | SUNON 12V 1.71W 75x75x30mm DC Centrifugal Blower for Industrial Cooling Within servers and data-center electronics, SUNON PF75301B2-1B00U-A99 serves as a 75 × 75 × 30 mm DC blower operating at 12 VDC. Its 3000 rpm rating defines a lower-speed operating point. The recorded sound level should guide acoustic assessment. Match the exact part number before approving a substitute. |
12 | 75x75x30mm | 23.4 | 107.1 | 1.71 | 3000 | 38.6 | |
![]() PMB1212PLB2-A (2).GN | SUNON 12V 9.8W 120x120x32mm DC Centrifugal Blower for Industrial Cooling Applied in industrial electronics and equipment cooling, SUNON PMB1212PLB2-A (2).GN is a 12 VDC DC blower in a 120 × 120 × 32 mm frame. Its 2500 rpm rating defines a lower-speed operating point. Treat the airflow profile as a primary input to acoustic assessment. Match the exact part number before approving a substitute. |
12 | 120*120*32 | 61.03 | - | 9.8 | 2500 | 53.8 | |
![]() PMB2497PYB1-AY (2).GN | SUNON 24V 6.96W 97x94x33mm DC Centrifugal Blower for Industrial Cooling Within industrial electronics and equipment cooling, SUNON PMB2497PYB1-AY (2).GN serves as a 97 × 94 × 33 mm DC blower operating at 24 VDC. The supplied data list 185 dB, an important acoustic selection parameter. Base power-budget planning on the stated application data. Confirm control inputs against the complete ordering code. |
24 | 97x94x33mm | 51.8 | - | 6.96 | 3600 | 185 | |
![]() FFB0924VHE | Delta Electronics 24VDC 6.72W Axial Fan for Server and Telecommunications Cooling FFB0924VHE provides 24VDC axial fan cooling for servers and telecom equipment in a 92 x 92 x 38 mm format. A listed 3800 rpm speed accompanies 145.2 m3/h maximum airflow and a 6.72 W electrical input. |
24 | 92×92×38.00 | 145.2 | 101 | 6.72 | 3800 | 47.5 | |
![]() AFB0812L | Delta Electronics 12VDC 1.08W Axial Fan for Server and Power Supply Cooling The AFB0812L pairs a 1.08 W input rating with a 2700 rpm axial fan rotor for server and power-supply cooling. Powered by 12VDC, it occupies 80 x 80 x 25.4 mm and lists a maximum airflow of 53.4 m3/h. |
12 | 80x80x25.4 | 53.4 | 32.17 | 1.08 | 2700 | 28 | |
![]() AFB0712MB-F00 | Delta Electronics 12VDC 1.68W Axial Fan for Server and Power Supply Cooling AFB0712MB-F00 is a 12VDC axial fan for server and power-supply cooling with a 70 x 70 x 15 mm body. Its listed 3300 rpm speed and 1.68 W input distinguish the model from higher-speed 70 mm alternatives. |
12 | 70×70×15.00 | 47.9 | 30.6 | 1.68 | 3300 | 31 | |
![]() EFB0812HHB | Delta Electronics 12VDC 3.96W Axial Fan for Industrial Equipment Cooling For industrial equipment ventilation, EFB0812HHB pairs a 3800 rpm axial fan rotor with a 12VDC supply. A 15 mm-deep, 80 mm frame and 3.96 W listed input define its fit, with 82.92 m3/h maximum airflow specified. |
12 | 80x80x15 | 82.92 | 42.66 | 3.96 | 3800 | 41 | |
![]() AFB0912VH-R00 | Delta Electronics 12VDC 4.8W Axial Fan for Server and Power Supply Cooling AFB0912VH-R00 provides a suffix-specific 12VDC axial fan cooling option for server chassis. Rated dimensions are 92 x 92 x 25 mm; the listed 4.8 W input is relevant when budgeting power for multiple enclosure fans. |
12 | 92*92*25 | 115.26 | 75.2 | 4.8 | 3800 | 45 | |
![]() EFB0405LA-F00 | Delta Electronics 5VDC 0.35W Axial Fan for Industrial Equipment Cooling A listed 0.35 W input is the standout selection point of EFB0405LA-F00 for industrial electronics. This 5VDC axial fan uses a 40 x 40 x 10 mm frame and a 4000 rpm rotor for its compact cooling format. |
5 | 40*40*10 | 6.358 | - | 0.35 | 4000 | 20.5 | |
![]() AFB1212VH | Delta Electronics 12VDC 4.8W Axial Fan for Server and Power Supply Cooling AFB1212VH combines a 25 mm-deep, 120 mm axial fan frame with 12VDC operation for server and power-supply cooling. The model lists a 3100 rpm speed and 4.8 W input, offering a defined alternative to faster variants. |
12 | 120*120*25 | 61 | 9 | 4.8 | 3100 | 44.5 | |
![]() AFB1212SH | Delta Electronics 12VDC 6.36W Axial Fan for Server and Power Supply Cooling AFB1212SH uses a 3400 rpm axial fan rotor for server and power-supply ventilation on 12VDC. Its 120 x 120 x 25 mm body and listed 6.36 W input distinguish its electrical and mechanical fit within the range. |
12 | 120*120*25 | 66.5 | 11 | 6.36 | 3400 | 46.5 | |
![]() TFB0412EHN | Delta Electronics 12VDC 8.64W DC Fan for Electronic Equipment Cooling TFB0412EHN is a 12VDC brushless fan for electronic equipment cooling, specified at 15000 rpm. A 40 x 40 x 28 mm envelope houses the assembly, with 44.251 m3/h listed maximum airflow and 8.64 W input. |
12 | 40*40*28 | 44.251 | - | 8.64 | 15000 | 58 | |
![]() FFB1424SHG | Delta Electronics 24VDC 36W Axial Fan for Server and Telecommunications Cooling The FFB1424SHG offers a 139.7 x 139.7 x 50.8 mm axial fan assembly for server and telecom cooling. Rated for 24VDC, it lists 464 m3/h maximum airflow and 3600 rpm operation, with 36 W input power specified. |
24 | 139.7×139.7×50.8 | 464 | 194.5 | 36 | 3600 | 61.7 | |
![]() FFB0824EHE-F00 | Delta Electronics 24VDC 12W Axial Fan for Server and Telecom Cooling FFB0824EHE-F00 is a 24VDC axial fan for telecom and server enclosures with an 80 x 80 x 38 mm body. Its listed 202.31 Pa maximum static pressure and 5700 rpm speed define the specified airflow profile. |
24 | 80x80x38 | 136.2 | 202.31 | 12 | 5700 | 52.5 | |
![]() FFB0812SH-F00 | Delta Electronics 12VDC 6W Axial Fan for Server and Telecommunications Cooling FFB0812SH-F00 is a 12VDC axial fan for telecom equipment requiring an 80 mm footprint. The 25.4 mm profile is shallower than the 38 mm EHE format, while this model lists a 4500 rpm speed and 6 W electrical load. |
12 | 80x80x25.4 | 113.88 | 97.58 | 6 | 4500 | 48.6 | |
![]() EFB0812HHB-F00 | Delta Electronics 12VDC 3.96W Axial Fan for Industrial Equipment Cooling EFB0812HHB-F00 combines a 15 mm-deep, 80 mm square axial fan frame with 12VDC operation. Intended for industrial equipment cooling, it lists 82.2 m3/h maximum airflow and 3800 rpm speed, with 3.96 W input. |
12 | 80×80×15.00 | 82.2 | 42.6 | 3.96 | 3800 | 41 |
The most reliable way to specify blower Fans is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.
Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.
Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.
End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 241 products are available in this category today.
The daily work of our sales engineers is built around blower Fans used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.
A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.
Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.
From one-piece emergency replacements to volume supply for equipment manufacturers, every enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.
Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.
Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 241 products in this category are listed online.
Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.