Positioned for servers and data-center electronics, SUNON GF40282B1-10000-ADP is a 24 VDC DC axial fan in a 40 × 40 × 28 mm frame. 343.7 Pa maximum pressure is the standout documented duty-point value. Base cabinet ventilation planning on the stated model record. Verify bearing and signal options in the exact datasheet.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 40x40x28mm |
| Max.Air Flow(m³/h) | 33.3 |
| Max.Pressure(Pa) | 343.7 |
| Speed(rpm) | 4600 |
| Noise(db) | 52.8 |
The GF40282B1-10000-ADP from SUNON addresses cooling needs in server and data-center equipment. As a DC brushless axial fan, it creates a defined inlet-to-outlet route across the thermal load.
With up to 33.3 m3/h listed airflow, the fan provides a measurable starting point for thermal design. Clear inlet space and a controlled outlet help preserve useful flow. The matching document lists IP68 protection, providing a defined basis for environmental exposure review.
The final GF40282B1-10000-ADP selection should consider connector reach as part of the installation layout. Finishing prototype trials before design lock helps reduce integration uncertainty and supports reliable equipment cooling. Confirm that the mating lead reaches without tension or sharp bending.
SUNON GF40282B1-10000-ADP serves server platforms. Airflow around processors, memory and power components helps address sustained computing loads. The fan gives OEM equipment a defined air route and supports stable server operation. It supports reliable equipment cooling.
SUNON GF40282B1-10000-ADP serves storage equipment. Airflow around drives, controllers and power assemblies helps address continuous data workloads. The fan gives OEM equipment a defined air route and supports reliable storage availability. It supports reliable equipment cooling.
SUNON GF40282B1-10000-ADP serves edge-computing systems. Airflow around compact processing and communication modules helps address high heat density. The fan gives OEM equipment a defined air route and supports consistent thermal control. It supports reliable equipment cooling.
SUNON GF40282B1-10000-ADP serves data-center equipment. Airflow around critical computing assemblies helps address round-the-clock heat generation. The fan gives OEM equipment a defined air route and supports infrastructure availability. It supports reliable equipment cooling.
The worksheet lists 52.8 dB. Installation distance, airflow resistance, and enclosure acoustics can change the measured result.
The supplied product-line reference discusses long-life cooling, but continuous-duty limits for this full suffix must be verified from its datasheet and operating conditions.
Yes. The worksheet lists up to 343.7 Pa; compare it with the system curve.
Use the listed voltage, size, 33.3 m³/h airflow, 4600 rpm for preliminary comparison.
It is listed for servers and data-center electronics. Check dimensions, airflow, pressure, and the installation environment against the actual equipment.

Used in servers and data-center electronics, SUNON GF40282BX-10000-ADP is a 24 VDC DC axial fan in a 40 × 40 × 28 mm frame. 500.7 Pa maximum pressure is the standout documented duty-point value. The recorded power demand should guide cooling-margin review. Check the full suffix before confirming connector details.
Read More
SUNON configures GF40282B3-10000-ADP as a 40 × 40 × 28 mm DC axial fan for servers and data-center electronics, operating at 24 VDC. Its 500 rpm rating defines a lower-speed operating point. Treat the pressure capability as a primary input to cooling-margin review. Check the full suffix before confirming connector details.
Read More
For servers and data-center electronics, GF40282B2-10000-ADP combines 24 VDC operation with a 40 × 40 × 28 mm DC axial fan design. 276.5 Pa maximum pressure is the standout documented duty-point value. For cooling-margin review, start with the supplied speed benchmark. Check the full suffix before confirming connector details.
Read More
Within servers and data-center electronics, SUNON GF40282B3-10000-SDP serves as a 40 × 40 × 28 mm DC axial fan operating at 24 VDC. 10500 W input is the defining electrical load in the supplied data. For cooling-margin review, start with the supplied frame geometry. Check the full suffix before confirming connector details.
Read More
GF40282B3-10000-QDP addresses servers and data-center electronics through a 24 VDC DC axial fan platform measuring 40 × 40 × 28 mm. 10500 W input is the defining electrical load in the supplied data. Use the documented cooling output when planning cooling-margin review. Check the full suffix before confirming connector details.
Read More
The GF40282B3-10000-AEP is SUNON's 24 VDC, 40 × 40 × 28 mm DC axial fan option for servers and data-center electronics. Its 500 rpm rating defines a lower-speed operating point. Review its operating point during cooling-margin review. Check the full suffix before confirming connector details.
Read More