Home > Products > By type > Axial Fans > GF40282BX-10000-ADP | SUNON 24V 40x40x28mm 40.6m3/h 7600rpm DC Axial Fan for Data Center Cooling

GF40282BX-10000-ADP SUNON Axial Fan

Brand :
SUNON
Model:
GF40282BX-10000-ADP | SUNON 24V 40x40x28mm 40.6m3/h 7600rpm DC Axial Fan for Data Center Cooling
Type:
Axial Fans
Industry:
Data Center Cooling
Description:

Used in servers and data-center electronics, SUNON GF40282BX-10000-ADP is a 24 VDC DC axial fan in a 40 × 40 × 28 mm frame. 500.7 Pa maximum pressure is the standout documented duty-point value. The recorded power demand should guide cooling-margin review. Check the full suffix before confirming connector details.

Datasheet:
GF40282BX-10000-ADP | SUNON 24V 40x40x28mm 40.6m3/h 7600rpm DC Axial Fan for Data Center Cooling Datasheet (Pdf)

Product Features

Rated Voltage(V)24
Size(mm)40x40x28mm
Max.Air Flow(m³/h)40.6
Max.Pressure(Pa)500.7
Speed(rpm)7600
Noise(db)58.5

Product Features

Reliable Fan Cooling

The SUNON GF40282BX-10000-ADP positions a DC brushless axial fan for server and data-center equipment. Its airflow path supports heat removal from enclosed components and toward the equipment exhaust.

An airflow ceiling of 40.6 m3/h helps procurement teams compare models for the intended heat load. Actual cooling depends on how the installation guides air across components. The matching document lists IP68 protection, providing a defined basis for environmental exposure review.

Design approval for GF40282BX-10000-ADP should cover cable routing together with replacement-fit checks before design lock. This creates a practical link between thermal validation, purchasing documentation and future servicing. Secure conductors away from the impeller and high-temperature components.

Application Industry

Frequently Asked Questions

Which performance figures define GF40282BX-10000-ADP?

Use the listed voltage, size, 40.6 m³/h airflow, 7600 rpm for preliminary comparison.

Can GF40282BX-10000-ADP serve high-reliability cooling systems?

Assess reliability from the exact bearing, temperature, protection, and life data. The supplied series note alone does not confirm every suffix-specific option.

Which selection data still require confirmation for GF40282BX-10000-ADP?

Confirm any missing bearing, connector, control, IP rating, life, certification, and performance-curve details for the complete part number.

What maintenance is recommended for GF40282BX-10000-ADP?

Inspect for dust, blocked airflow, abnormal noise, loose mounting, and wiring damage. Isolate power before cleaning or service.

Why choose GF40282BX-10000-ADP over a general cooling fan?

Its documented 24 VDC rating and 500.7 pa maximum pressure is the standout documented duty-point value. allow comparison with the required duty point without assuming unlisted options.