For servers and data-center electronics, GF40282B2-10000-ADP combines 24 VDC operation with a 40 × 40 × 28 mm DC axial fan design. 276.5 Pa maximum pressure is the standout documented duty-point value. For cooling-margin review, start with the supplied speed benchmark. Check the full suffix before confirming connector details.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 40x40x28mm |
| Max.Air Flow(m³/h) | 30.1 |
| Max.Pressure(Pa) | 276.5 |
| Speed(rpm) | 3100 |
| Noise(db) | 50 |
The SUNON GF40282B2-10000-ADP positions a DC brushless axial fan for server and data-center equipment. Its airflow path supports heat removal from enclosed components and toward the equipment exhaust.
The matching document lists IP68 protection, providing a defined basis for environmental exposure review. Rigid mounting and clear breathing space help control vibration, flow loss and the acoustic result of the complete assembly.
OEM teams specifying GF40282B2-10000-ADP should check airflow direction and complete replacement-fit checks before design lock. A documented interface review helps purchasing teams control fit, cooling continuity and replacement planning. Verify orientation so heated air does not recirculate through the inlet.
SUNON GF40282B2-10000-ADP serves server platforms. Airflow around processors, memory and power components helps address sustained computing loads. The fan gives OEM equipment a defined air route and supports stable server operation. It supports reliable equipment cooling.
SUNON GF40282B2-10000-ADP serves storage equipment. Airflow around drives, controllers and power assemblies helps address continuous data workloads. The fan gives OEM equipment a defined air route and supports reliable storage availability. It supports reliable equipment cooling.
SUNON GF40282B2-10000-ADP serves edge-computing systems. Airflow around compact processing and communication modules helps address high heat density. The fan gives OEM equipment a defined air route and supports consistent thermal control. It supports reliable equipment cooling.
SUNON GF40282B2-10000-ADP serves data-center equipment. Airflow around critical computing assemblies helps address round-the-clock heat generation. The fan gives OEM equipment a defined air route and supports infrastructure availability. It supports reliable equipment cooling.
The exact IP or protection option is not stated in the supplied row. Confirm the full suffix in the applicable SUNON datasheet.
Inspect for dust, blocked airflow, abnormal noise, loose mounting, and wiring damage. Isolate power before cleaning or service.
Its documented 24 VDC rating and 276.5 pa maximum pressure is the standout documented duty-point value. allow comparison with the required duty point without assuming unlisted options.
The listed speed is 3100 rpm. Confirm frequency, control method, and duty point for the installed system.
The supplied product-line reference discusses long-life cooling, but continuous-duty limits for this full suffix must be verified from its datasheet and operating conditions.

Used in servers and data-center electronics, SUNON GF40282BX-10000-ADP is a 24 VDC DC axial fan in a 40 × 40 × 28 mm frame. 500.7 Pa maximum pressure is the standout documented duty-point value. The recorded power demand should guide cooling-margin review. Check the full suffix before confirming connector details.
Read More
SUNON configures GF40282B3-10000-ADP as a 40 × 40 × 28 mm DC axial fan for servers and data-center electronics, operating at 24 VDC. Its 500 rpm rating defines a lower-speed operating point. Treat the pressure capability as a primary input to cooling-margin review. Check the full suffix before confirming connector details.
Read More
Positioned for servers and data-center electronics, SUNON GF40282B1-10000-ADP is a 24 VDC DC axial fan in a 40 × 40 × 28 mm frame. 343.7 Pa maximum pressure is the standout documented duty-point value. Base cabinet ventilation planning on the stated model record. Verify bearing and signal options in the exact datasheet.
Read More
Within servers and data-center electronics, SUNON GF40282B3-10000-SDP serves as a 40 × 40 × 28 mm DC axial fan operating at 24 VDC. 10500 W input is the defining electrical load in the supplied data. For cooling-margin review, start with the supplied frame geometry. Check the full suffix before confirming connector details.
Read More
GF40282B3-10000-QDP addresses servers and data-center electronics through a 24 VDC DC axial fan platform measuring 40 × 40 × 28 mm. 10500 W input is the defining electrical load in the supplied data. Use the documented cooling output when planning cooling-margin review. Check the full suffix before confirming connector details.
Read More
The GF40282B3-10000-AEP is SUNON's 24 VDC, 40 × 40 × 28 mm DC axial fan option for servers and data-center electronics. Its 500 rpm rating defines a lower-speed operating point. Review its operating point during cooling-margin review. Check the full suffix before confirming connector details.
Read More