Within servers and data-center electronics, SUNON GF80382BX-10000-SDP serves as a 40 × 40 × 28 mm DC axial fan operating at 24 VDC. 10000 W input is the defining electrical load in the supplied data. Treat the electrical load as a primary input to spares assessment. Confirm control inputs against the complete ordering code.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 40x40x28mm |
| Max.Air Flow(m³/h) | 226 |
| Max.Pressure(Pa) | 438.4 |
| Input Power(W) | 10000 |
| Speed(rpm) | 10000 |
| Noise(db) | 64.3 |
Equipment builders can integrate SUNON GF80382BX-10000-SDP, a DC brushless axial fan, into industrial equipment. The design supplies the air movement required to carry component heat out of confined spaces.
The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market. Correct airflow direction and inlet clearance help translate the documented operating point into reliable equipment-level cooling.
Before adopting GF80382BX-10000-SDP, engineers should evaluate mounting rigidity. Carry out acoustic evaluation during sourcing review so the chosen fan can be released with clear installation and sourcing requirements. Measure sound after mounting because the enclosure changes transmission.
The exact bearing option is not confirmed by the row-level data. Check the complete suffix in the current SUNON specification.
Review its 40 × 40 × 28 mm size, 226 m³/h airflow, 438.4 Pa pressure, system resistance, and available mounting space.
It is listed for servers and data-center electronics. Check dimensions, airflow, pressure, and the installation environment against the actual equipment.
The supplied row does not state the connector or lead configuration. Follow the model-specific wiring drawing.
Match voltage, dimensions, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.
Compare its listed 10000 W input with the required airflow and run time. Total savings depend on the complete system duty point.

Within servers and data-center electronics, SUNON GF40282B3-10000-SDP serves as a 40 × 40 × 28 mm DC axial fan operating at 24 VDC. 10500 W input is the defining electrical load in the supplied data. For cooling-margin review, start with the supplied frame geometry. Check the full suffix before confirming connector details.
Read More
SUNON GF40282B2-10000-SDP combines a 40 × 40 × 28 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. 13100 W input is the defining electrical load in the supplied data. Base cooling-margin review on the stated dimensional envelope. Check the full suffix before confirming connector details.
Read More
The GF40282B1-10000-SDP is SUNON's 24 VDC, 40 × 40 × 28 mm DC axial fan option for servers and data-center electronics. 14600 W input is the defining electrical load in the supplied data. Use the documented airflow profile when planning cooling-margin review. Check the full suffix before confirming connector details.
Read More
Used in servers and data-center electronics, SUNON GF40282BX-10000-ADP is a 24 VDC DC axial fan in a 40 × 40 × 28 mm frame. 500.7 Pa maximum pressure is the standout documented duty-point value. The recorded power demand should guide cooling-margin review. Check the full suffix before confirming connector details.
Read More
GF40282B3-10000-QDP addresses servers and data-center electronics through a 24 VDC DC axial fan platform measuring 40 × 40 × 28 mm. 10500 W input is the defining electrical load in the supplied data. Use the documented cooling output when planning cooling-margin review. Check the full suffix before confirming connector details.
Read More
The GF40282B3-10000-AEP is SUNON's 24 VDC, 40 × 40 × 28 mm DC axial fan option for servers and data-center electronics. Its 500 rpm rating defines a lower-speed operating point. Review its operating point during cooling-margin review. Check the full suffix before confirming connector details.
Read More