1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-816
of 816
Download Table
Mfr Part # Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
VF80381B1-1Q04U-S9H | SUNON 12V 33.12W 80x80x38mm 125.2m3/h DC Axial Fan for Data Center Cooling

SUNON VF80381B1-1Q04U-S9H is a 12 VDC DC blower in a 80 × 80 × 38 mm format for servers and data-center electronics. 1.84 Pa maximum pressure is the standout documented duty-point value. For project documentation, start with the supplied sound level. Reconcile the model code with the required electrical interface.

12 80x80x38 125.2 1.84 33.12 10800 60.6
XG40561BX-1Q310-S9H | SUNON 40x40x56mm DC Axial Fan for Data Center Cooling

SUNON XG40561BX-1Q310-S9H combines a 40 × 40 × 56 mm DC blower platform with a 0 VDC rating for servers and data-center electronics. Its 40 × 40 × 56 mm format is the main stated selection detail. Use the documented rotational rating when planning project documentation. Reconcile the model code with the required electrical interface.

0 40x40x56 - - - - -
XG40561BX-1Q25U-S9T | SUNON 40x40x56mm DC Axial Fan for Data Center Cooling

SUNON configures XG40561BX-1Q25U-S9T as a 40 × 40 × 56 mm DC blower for servers and data-center electronics, operating at 0 VDC. Its 40 × 40 × 56 mm format is the main stated selection detail. The recorded pressure capability should guide project documentation. Reconcile the model code with the required electrical interface.

0 40x40x56 - - - - -
VG40561BX-0000-A9H | SUNON 12V 16.8W 40x40x56mm 42.5m3/h DC Axial Fan for Data Center Cooling

Designed for servers and data-center electronics, SUNON VG40561BX-0000-A9H is a 12 VDC DC axial fan in a 40 × 40 × 56 mm frame. 1541.9 Pa maximum pressure is the standout documented duty-point value. Use the documented acoustic value when planning project documentation. Reconcile the model code with the required electrical interface.

12 40x40x56mm 42.5 1541.9 16.8 - 65
VG40561B1-0000-A9H | SUNON 12V 9W 40x40x56mm 33.5m3/h DC Axial Fan for Data Center Cooling

Within servers and data-center electronics, SUNON VG40561B1-0000-A9H serves as a 40 × 40 × 56 mm DC axial fan operating at 12 VDC. 1036.2 Pa maximum pressure is the standout documented duty-point value. Review its electrical load during project documentation. Reconcile the model code with the required electrical interface.

12 40x40x56mm 33.5 1036.2 9 - 62.5
VG60561BX-1Q014-S9HP | SUNON 12V 61.2W 60x60x56mm 140m3/h DC Axial Fan for Data Center Cooling

The VG60561BX-1Q014-S9HP is SUNON's 12 VDC, 60 × 60 × 56 mm DC blower option for servers and data-center electronics. 18400 rpm is the model's most distinctive operating parameter. Base project documentation on the stated airflow profile. Reconcile the model code with the required electrical interface.

12 60x60x56 140 - 61.2 18400 79.1
HA40101V4-1D070-G99 | SUNON 12V 0.38W 40x40x10mm 9.2m3/h DC Axial Fan for Data Center Cooling

Used in servers and data-center electronics, SUNON HA40101V4-1D070-G99 is a 12 VDC DC axial fan in a 40 × 40 × 10 mm frame. A listed noise value of 15.7 dB is the model's key differentiator. Treat the acoustic value as a primary input to reliability evaluation. Treat bearing and life data as suffix-specific.

12 40x40x10mm 9.2 22.4 0.38 5000 15.7
PFE0514B1-0000-A99 | SUNON 48V 22.56W 140x140x51mm 5000rpm DC Axial Fan for Data Center Cooling

Equipment designers working with servers and data-center electronics can evaluate SUNON PFE0514B1-0000-A99, a DC axial fan rated at 48 VDC and sized 140 × 140 × 51 mm. Up to 425.3 m³/h is its most prominent listed performance figure. During reliability evaluation, compare the model's speed benchmark. Treat bearing and life data as suffix-specific.

48 140x140x51mm 425.3 356.2 22.56 5000 61.4
PFE0384BX-0000-A99 | SUNON 48V 35.52W 140x140x38mm 6600rpm DC Axial Fan for Data Center Cooling

The PFE0384BX-0000-A99 is SUNON's 48 VDC, 140 × 140 × 38 mm DC axial fan option for servers and data-center electronics. Up to 480.1 m³/h is its most prominent listed performance figure. The recorded airflow profile should guide reliability evaluation. Treat bearing and life data as suffix-specific.

48 140x140x38mm 480.1 468.3 35.52 6600 65.9
PFE0381BX-0000-A99 | SUNON 12V 39.6W 140x140x38mm 506.1m3/h DC Axial Fan for Data Center Cooling

For compact cooling within servers and data-center electronics, the PFE0381BX-0000-A99 provides a 12 VDC DC axial fan configuration measuring 140 × 140 × 38 mm. Up to 506.1 m³/h is its most prominent listed performance figure. For operating-cost analysis, start with the supplied application data. Validate mounting and wiring from the model drawing.

12 140x140x38mm 506.1 510.6 39.6 6800 68.3
PFE0381B1-0000-A99 | SUNON 12V 20.64W 140x140x38mm 5500rpm DC Axial Fan for Data Center Cooling

SUNON PFE0381B1-0000-A99 combines a 140 × 140 × 38 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. Up to 405.2 m³/h is its most prominent listed performance figure. Use the documented technical profile when planning operating-cost analysis. Validate mounting and wiring from the model drawing.

12 140x140x38mm 405.2 298.9 20.64 5500 62
PF97331BX-B000-A99 | SUNON 12V 42W 97x95x33mm DC Centrifugal Blower for Data Center Cooling

Applied in servers and data-center electronics, SUNON PF97331BX-B000-A99 is a 12 VDC DC blower in a 97 × 95 × 33 mm frame. 1300.2 Pa maximum pressure is the standout documented duty-point value. Review its model record during operating-cost analysis. Validate mounting and wiring from the model drawing.

12 97x95x33mm 92.9 1300.2 42 6800 63.2
PF97331B1-B000-A99 | SUNON 12V 19.2W 97x95x33mm DC Centrifugal Blower for Data Center Cooling

Within servers and data-center electronics, SUNON PF97331B1-B000-A99 serves as a 97 × 95 × 33 mm DC blower operating at 12 VDC. 844.4 Pa maximum pressure is the standout documented duty-point value. Treat the product configuration as a primary input to operating-cost analysis. Validate mounting and wiring from the model drawing.

12 97x95x33mm 75.1 844.4 19.2 5400 58
PF92382B3-10000-A9H | SUNON 24V 6W 92x92x38mm 155.8m3/h DC Axial Fan for Data Center Cooling

Equipment designers working with servers and data-center electronics can evaluate SUNON PF92382B3-10000-A9H, a DC axial fan rated at 24 VDC and sized 92 × 92 × 38 mm. Up to 155.8 m³/h is its most prominent listed performance figure. Base operating-cost analysis on the stated system interface. Validate mounting and wiring from the model drawing.

24 92x92x38mm 155.8 127 6 4700 49.5
PF92382B2-10000-A9H | SUNON 24V 11.52W 92x92x38mm 204.2m3/h DC Axial Fan for Data Center Cooling

The PF92382B2-10000-A9H is SUNON's 24 VDC, 92 × 92 × 38 mm DC axial fan option for servers and data-center electronics. Up to 204.2 m³/h is its most prominent listed performance figure. During operating-cost analysis, compare the model's cooling specification. Validate mounting and wiring from the model drawing.

24 92x92x38mm 204.2 179.3 11.52 5800 54.7
PF92381B3-10000-A9H | SUNON 12V 5.82W 92x92x38mm 155.8m3/h DC Axial Fan for Data Center Cooling

SUNON PF92381B3-10000-A9H combines a 92 × 92 × 38 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. Up to 155.8 m³/h is its most prominent listed performance figure. For operating-cost analysis, start with the supplied installation footprint. Validate mounting and wiring from the model drawing.

12 92x92x38mm 155.8 127 5.82 4700 49.5
PF92381B2-10000-A9H | SUNON 12V 11.22W 92x92x38mm 204.2m3/h DC Axial Fan for Data Center Cooling

Positioned for servers and data-center electronics, SUNON PF92381B2-10000-A9H is a 12 VDC DC axial fan in a 92 × 92 × 38 mm frame. Up to 204.2 m³/h is its most prominent listed performance figure. Use the documented selection parameters when planning operating-cost analysis. Validate mounting and wiring from the model drawing.

12 92x92x38mm 204.2 179.3 11.22 5800 54.7
PF92381B1-10000-A9H | SUNON 12V 22.2W 92x92x38mm 234.6m3/h DC Axial Fan for Data Center Cooling

Within servers and data-center electronics, SUNON PF92381B1-10000-A9H serves as a 92 × 92 × 38 mm DC axial fan operating at 12 VDC. Up to 234.6 m³/h is its most prominent listed performance figure. Review its rated dataset during operating-cost analysis. Validate mounting and wiring from the model drawing.

12 92x92x38mm 234.6 485.7 22.2 9300 62.9
PF92252V3-10000-A99 | SUNON 24V 3.03W 92x92x25mm 110.4m3/h DC Axial Fan for Data Center Cooling

SUNON PF92252V3-10000-A99 is a 24 VDC DC axial fan in a 92 × 92 × 25 mm format for servers and data-center electronics. Up to 110.4 m³/h is its most prominent listed performance figure. Treat the motor input as a primary input to operating-cost analysis. Validate mounting and wiring from the model drawing.

24 92x92x25mm 110.4 62.3 3.03 3900 41.6
PF92252V2-10000-A99 | SUNON 24V 3.48W 92x92x25mm 118.9m3/h DC Axial Fan for Data Center Cooling

The PF92252V2-10000-A99 is SUNON's 24 VDC, 92 × 92 × 25 mm DC axial fan option for servers and data-center electronics. Up to 118.9 m³/h is its most prominent listed performance figure. Base operating-cost analysis on the stated ventilation capacity. Validate mounting and wiring from the model drawing.

24 92x92x25mm 118.9 74.7 3.48 4200 43.7
Showing
441-460
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-816
of 816
1 2 ... 20 21 22 23 24 25 26 ... 40 41
GO page

About Data Center Cooling

Data center cooling fans are specialized ventilation components engineered to maintain the precise temperature and humidity requirements of modern computing infrastructure. As data centers grow in density with higher TDP processors and accelerated adoption of AI and HPC workloads, cooling fan performance and energy efficiency have become critical operational concerns. Data center cooling fans serve three primary architectural roles: server-level fans (120mm DC axial fans mounted in server chassis for direct component cooling), rack-level cooling (inline or roof-mounted EC fans for hot-aisle containment systems), and facility-level HVAC fans (air handling units with EC backward curved centrifugal blowers for building-wide circulation). Key design requirements for data center fans include: reliability (MTBF typically exceeding 100,000 hours), quiet operation (dBA levels for occupied spaces), EC technology for energy efficiency and variable speed, PWM or Modbus control for intelligent thermal management, and hot-swap capability for critical systems. Leading manufacturers include ebm-papst, ZIEHL-ABEGG, Rosenberg, Sanyo Denki, and SUNON. Hengrui supplies data center cooling fans with cross-reference tools, competitive pricing, and engineering consultation.

How to Select the Right Data Center Cooling

The most reliable way to specify data Center Cooling is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.

Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.

Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.

End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 816 products are available in this category today.

Typical Applications and Use Cases for Data Center Cooling

The daily work of our sales engineers is built around data Center Cooling used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.

A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.

Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.

From one-piece emergency replacements to volume supply for equipment manufacturers, every enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.

Frequently Asked Questions About Buying Data Center Cooling

What technical documentation do you provide before purchase?

Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.

Do you have data Center Cooling in stock and how fast can you deliver?

Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 816 products in this category are listed online.

Can you replace my existing data Center Cooling from another supplier or a discontinued model?

Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.

Bag

Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.