Home > Products > By industry > Data Center Cooling

Data Center Cooling

By brand

By type

Rated Voltage(V)

Size(mm)

Max.Air Flow(m³/h)

Max.Pressure(Pa)

Input Power(W)

Speed(rpm)

Noise(db)

Stocking Options

Environmental Options

Media

Exclude

816 results

Applied Filters

Showing
401-420
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-816
of 816
Download Table
Mfr Part # Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
9G1224E102 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki configures 9G1224E102 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 120 × 120 × 38 mm dimensions. The 120 × 120 × 38 mm format is the primary stated selection detail. Treat the installation footprint as a primary input to controller selection. Verify the exact bearing and signal options in the datasheet.

24 120*120*38 - - - - -
109P0405H902 | Sanyo Denki 5VDC 0.8W DC Axial Fan for UPS, server and telecom equipment cooling

For thermal management in servers, UPS systems, and telecom equipment, the 109P0405H902 provides a 5 VDC DC axial fan configuration measuring 40 × 40 × 10 mm. The 9 m³/h airflow figure supports its stated equipment-cooling role. Review its rated dataset during maintenance preparation. Verify the exact bearing and signal options in the datasheet.

5 40*40*10 9 41.2 0.8 6200 25
109P0424J3073 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

109P0424J3073 serves servers, UPS systems, and telecom equipment as a 40 × 40 × 28 mm DC axial fan rated at 24 VDC. Series focus: high airflow and pressure. The 40 × 40 × 28 mm format is the primary stated selection detail. Check enclosure space planning suffix definition. Focus: enclosure space planning suffix definition.

24 40*40*28 - - - - -
109P0424H6D23 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki configures 109P0424H6D23 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 40 × 40 × 20 mm dimensions. The 40 × 40 × 20 mm format is the primary stated selection detail. Base power-budget planning on the stated static-pressure entry. Validate mounting and wiring from the model drawing.

24 40*40*20 - - - - -
9G1224A402 | Sanyo Denki 24VDC 5.04W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki configures 9G1224A402 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 120 × 120 × 25 mm dimensions. Its listed airflow of 170 m³/h is the standout performance value. Treat the sound level as a primary input to acoustic assessment. Treat bearing and life data as suffix-specific.

24 120*120*25 170 - 5.04 3150 44
9GA0412P3M01 | Sanyo Denki 12VDC 2.52W DC Axial Fan for UPS, server and telecom equipment cooling

A 40 × 40 × 28 mm frame and 12 VDC rating define 9GA0412P3M01, a DC axial fan for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. 12500 rpm is the model's most prominent operating value. Check enclosure space planning static-pressure entry.

12 40*40*28 27.6 258 2.52 12500 47
9G1224A4D01 | Sanyo Denki 24VDC 5.04W DC Axial Fan for UPS, server and telecom equipment cooling

9G1224A4D01 serves servers, UPS systems, and telecom equipment as a 120 × 120 × 32 mm DC axial fan rated at 24 VDC. Series focus: high airflow and pressure. Its listed airflow of 170 m³/h is the standout performance value. Check enclosure space planning volume-flow figure. Focus: enclosure space planning volume-flow figure.

24 120*120*32 170 - 5.04 3150 44
9G1224H4D01 | Sanyo Denki 24VDC 4.08W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki configures 9G1224H4D01 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 120 × 120 × 25 mm dimensions. Its 2850 rpm rating defines a lower-speed operating point. For thermal validation, start with the supplied motor input. Obtain the applicable curve before final duty-point approval.

24 120*120*25 151 - 4.08 2850 40
9A0924H4D01 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

The 9A0924H4D01 is a Sanyo Denki 24 VDC, 92 × 92 × 25 mm DC axial fan for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. For mounting verification, start with the supplied cooling specification. Use current model documentation to validate protection choices.

24 92*92*25 87.04 - - 3150 33
9S1212P4M011 | Sanyo Denki 12VDC 1.56W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki 9S1212P4M011 is a 12 VDC DC axial fan in a 120 × 120 × 25 mm format for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Its 1850 rpm rating defines a lower-speed operating point. Check enclosure space planning operating point. Focus: enclosure space planning operating point.

12 120*120*25 99.6 22.7 1.56 1850 24
9G1224G4D01 | Sanyo Denki 24VDC 11.28W DC Axial Fan for UPS, server and telecom equipment cooling

The 119 × 119 × 25 mm Sanyo Denki 9G1224G4D01 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. For cooling-margin review, start with the supplied pressure capability. Check the full suffix before confirming connector details. Focus: enclosure space planning.

24 119*119*25 218.4 120 11.28 4100 51
109P0424H7D28 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki configures 109P0424H7D28 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 40 × 40 × 15 mm dimensions. The 40 × 40 × 15 mm format is the primary stated selection detail. The recorded power demand should guide service-life planning. Treat bearing and life data as suffix-specific.

24 40*40*15 - - - - -
VG80861BX-Q070-S9H | SUNON 12V 90W 80x80x86mm 161.7m3/h DC Axial Fan for Data Center Cooling

The VG80861BX-Q070-S9H is SUNON's 12 VDC, 80 × 80 × 86 mm DC blower option for servers and data-center electronics. The supplied data list 81.1 dB, an important acoustic selection parameter. For system commissioning, start with the supplied acoustic value. Verify bearing and signal options in the exact datasheet.

12 80x80x86 161.7 7.15 90 15700/14600 81.1
VG80801BX-1Q014-S9H | SUNON 12V 128.4W 80x80x80mm 201.9m3/h DC Axial Fan for Data Center Cooling

The 12 VDC SUNON VG80801BX-1Q014-S9H is a DC blower sized 80 × 80 × 80 mm for servers and data-center electronics. The supplied data list 80.5 dB, an important acoustic selection parameter. Base technical purchasing on the stated installation footprint. Request the exact performance curve for final engineering signoff.

12 80x80x80 201.9 7.4 128.4 16500/13500 80.5
PF80801BX-0000-S9H | SUNON 12V 81.6W 80x80x80mm 151.5m3/h DC Axial Fan for Data Center Cooling

SUNON PF80801BX-0000-S9H combines a 80 × 80 × 80 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. The supplied data list 80.4 dB, an important acoustic selection parameter. For technical purchasing, start with the supplied motor input. Request the exact performance curve for final engineering signoff.

12 80x80x80 151.5 5.44 81.6 15600/14100 80.4
VG80561BX-Q140-S9H | SUNON 12V 48W 80x80x56mm 130.4m3/h DC Axial Fan for Data Center Cooling

Positioned for servers and data-center electronics, SUNON VG80561BX-Q140-S9H is a 12 VDC DC blower in a 80 × 80 × 56 mm frame. The supplied data list 77.3 dB, an important acoustic selection parameter. For technical purchasing, start with the supplied mounting size. Request the exact performance curve for final engineering signoff.

12 80x80x56 130.4 8.41 48 17000/14500 77.3
PF60761BX-0000-S99 | SUNON 12V 33.6W 60x60x76mm 73.2m3/h DC Axial Fan for Data Center Cooling

The PF60761BX-0000-S99 is SUNON's 12 VDC, 60 × 60 × 76 mm DC axial fan option for servers and data-center electronics. 3.96 Pa maximum pressure is the standout documented duty-point value. Review its operating point during technical purchasing. Request the exact performance curve for final engineering signoff.

12 60x60x76 73.2 3.96 33.6 18200/14700 68.6
XG60561BX-1Q017-S9H | SUNON 12V 56.4W 60x60x56mm 95.9m3/h DC Axial Fan for Data Center Cooling

Within servers and data-center electronics, SUNON XG60561BX-1Q017-S9H serves as a 60 × 60 × 56 mm DC blower operating at 12 VDC. The supplied data list 81.3 dB, an important acoustic selection parameter. The recorded electrical load should guide technical purchasing. Request the exact performance curve for final engineering signoff.

12 60x60x56 95.9 7.06 56.4 22000/20500 81.3
XG60561BX-1Q011-S9H | SUNON 12V 52.8W 60x60x56mm 83.3m3/h DC Axial Fan for Data Center Cooling

The XG60561BX-1Q011-S9H is SUNON's 12 VDC, 60 × 60 × 56 mm DC blower option for servers and data-center electronics. The supplied data list 78.3 dB, an important acoustic selection parameter. Use the documented airflow profile when planning technical purchasing. Request the exact performance curve for final engineering signoff.

12 60x60x56 83.3 9.31 52.8 23000/22000 78.3
VG60561BX-1Q010-S9H | SUNON 12V 61.2W 60x60x56mm 82.64m3/h DC Axial Fan for Data Center Cooling

Specified at 12 VDC, VG60561BX-1Q010-S9H is a SUNON DC blower for servers and data-center electronics in 60 × 60 × 56 mm dimensions. The supplied data list 79.1 dB, an important acoustic selection parameter. Review its application data during application screening. Validate approvals and protection at complete-part-number level.

12 60x60x56 82.64 9.05 61.2 21300/18400 79.1
Showing
401-420
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-816
of 816
1 2 ... 18 19 20 21 22 23 24 ... 40 41
GO page

About Data Center Cooling

Data center cooling fans are specialized ventilation components engineered to maintain the precise temperature and humidity requirements of modern computing infrastructure. As data centers grow in density with higher TDP processors and accelerated adoption of AI and HPC workloads, cooling fan performance and energy efficiency have become critical operational concerns. Data center cooling fans serve three primary architectural roles: server-level fans (120mm DC axial fans mounted in server chassis for direct component cooling), rack-level cooling (inline or roof-mounted EC fans for hot-aisle containment systems), and facility-level HVAC fans (air handling units with EC backward curved centrifugal blowers for building-wide circulation). Key design requirements for data center fans include: reliability (MTBF typically exceeding 100,000 hours), quiet operation (dBA levels for occupied spaces), EC technology for energy efficiency and variable speed, PWM or Modbus control for intelligent thermal management, and hot-swap capability for critical systems. Leading manufacturers include ebm-papst, ZIEHL-ABEGG, Rosenberg, Sanyo Denki, and SUNON. Hengrui supplies data center cooling fans with cross-reference tools, competitive pricing, and engineering consultation.

How to Select the Right Data Center Cooling

The most reliable way to specify data Center Cooling is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.

Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.

Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.

End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 816 products are available in this category today.

Typical Applications and Use Cases for Data Center Cooling

The daily work of our sales engineers is built around data Center Cooling used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.

A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.

Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.

From one-piece emergency replacements to volume supply for equipment manufacturers, every enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.

Frequently Asked Questions About Buying Data Center Cooling

What technical documentation do you provide before purchase?

Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.

Do you have data Center Cooling in stock and how fast can you deliver?

Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 816 products in this category are listed online.

Can you replace my existing data Center Cooling from another supplier or a discontinued model?

Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.

Bag

Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.