Get Quote
Home > Products > By industry > Data Center Cooling

Data Center Cooling

By brand

By type

Rated Voltage(V)

Size(mm)

Max.Air Flow(m³/h)

Max.Pressure(Pa)

Input Power(W)

Speed(rpm)

Noise(db)

Stocking Options

Environmental Options

Media

Exclude

816 results

Applied Filters

Showing
361-380
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-816
of 816
Download Table
Mfr Part # Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
109P0424H6D13 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

The 40 × 40 × 20 mm Sanyo Denki 109P0424H6D13 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. Review its sound level during acoustic assessment. Use current model documentation to validate protection choices. Focus: power budget review.

24 40*40*20 - - - - -
9GA0424P3J001 | Sanyo Denki 24VDC 6.48W DC Axial Fan for UPS, server and telecom equipment cooling

A 40 × 40 × 28 mm frame and 24 VDC rating define 9GA0424P3J001, a DC axial fan for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. 18000 rpm is the model's most prominent operating value. Check power budget review volume-flow figure. Focus: power budget review.

24 40*40*28 40.29 535 6.48 18000 54
9CR5748G9003 | Sanyo Denki 48VDC Counter-Rotating DC Axial Fan for UPS, server and telecom equipment cooling

The size not stated Sanyo Denki 9CR5748G9003 brings 48 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Series options require suffix verification. Base duty-point matching on the stated airflow profile. Use the latest specification for frequency and tolerance limits. Focus: power budget review rotational rating.

48 - - - - - -
9G1224M402 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki 9G1224M402 is a 24 VDC DC axial fan in a 120 × 120 × 25 mm format for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. The 120 × 120 × 25 mm format is the primary stated selection detail. Check power budget review frame geometry. Focus: power budget review.

24 120*120*25 - - - - -
109P0424H6D18 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

The 109P0424H6D18 is a Sanyo Denki 24 VDC, 40 × 40 × 20 mm DC axial fan for servers, UPS systems, and telecom equipment. The supplied reference emphasizes high static pressure and high airflow. Review its frame geometry during duty-point matching. Treat bearing and life data as suffix-specific. Selection focus: power budget review operating point.

24 40*40*20 - - - - -
109R0824S402 | Sanyo Denki 24VDC 2.4W DC Axial Fan for UPS, server and telecom equipment cooling

A 80 × 80 × 25 mm frame and 24 VDC rating define 109R0824S402, a DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. 48.1 Pa maximum pressure is the most distinctive duty-point parameter. Check power budget review pressure capability. Focus: power budget review pressure capability.

24 80*80*25 72.08 48.1 2.4 3400 34
109E1724H502 | Sanyo Denki 24VDC 13.92W DC Axial Fan for UPS, server and telecom equipment cooling

Within servers, UPS systems, and telecom equipment, 109E1724H502 provides a ø172 × 51 mm, 24 VDC DC axial fan configuration. High airflow is highlighted together with a high-static-pressure design. Its listed airflow of 384 m³/h is the standout performance value. Check power budget review dimensional envelope. Focus: power budget review.

24 ø172*51 384 137.2 13.92 3050 47
9G1224M4021 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

A 120 × 120 × 25 mm frame and 24 VDC rating define 9G1224M4021, a DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. The 120 × 120 × 25 mm format is the primary stated selection detail. Check power budget review acoustic value. Focus: power budget review acoustic value.

24 120*120*25 - - - - -
109E1724C503 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki configures 109E1724C503 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with ø172 × 51 mm dimensions. The ø172 × 51 mm format is the primary stated selection detail. Treat the system interface as a primary input to airflow-path design. Use the latest specification for frequency and tolerance limits.

24 ø172*51 - - - - -
9G1224M401 | Sanyo Denki 24VDC 1.92W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki configures 9G1224M401 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 120 × 120 × 25 mm dimensions. Its 1950 rpm rating defines a lower-speed operating point. Use the documented pressure capability when planning replacement evaluation. Validate mounting and wiring from the model drawing.

24 120*120*25 100 31 1.92 1950 29
109P1224H4021 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

109P1224H4021 serves servers, UPS systems, and telecom equipment as a 120 × 120 × 25 mm DC axial fan rated at 24 VDC. High airflow is highlighted together with a high-static-pressure design. The 120 × 120 × 25 mm format is the primary stated selection detail. Check power budget review airflow profile. Focus: power budget review airflow profile.

24 120*120*25 - - - - -
109P0424H701 | Sanyo Denki 24VDC 1.92W DC Axial Fan for UPS, server and telecom equipment cooling

For servers, UPS systems, and telecom equipment, 109P0424H701 combines 24 VDC operation with a 40 × 40 × 15 mm DC axial fan design. High airflow is highlighted together with a high-static-pressure design. The 10.8 m³/h airflow figure supports its stated equipment-cooling role. Check resistance curve checking installation footprint.

24 40*40*15 10.8 75.5 1.92 7700 28
109P0424H316 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki configures 109P0424H316 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 40 × 40 × 28 mm dimensions. The 40 × 40 × 28 mm format is the primary stated selection detail. The recorded motor input should guide spares assessment. Match the exact part number before approving a substitute.

24 40*40*28 - - - - -
109P1224H402 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki configures 109P1224H402 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 120 × 120 × 25 mm dimensions. The 120 × 120 × 25 mm format is the primary stated selection detail. The recorded supply requirement should guide enclosure sizing. Verify the exact bearing and signal options in the datasheet.

24 120*120*25 - - - - -
109P0405F602 | Sanyo Denki 5VDC DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki configures 109P0405F602 for servers, UPS systems, and telecom equipment as a 5 VDC DC axial fan with 40 × 40 × 20 mm dimensions. The 40 × 40 × 20 mm format is the primary stated selection detail. Review its electrical load during procurement comparison. Use the latest specification for frequency and tolerance limits.

5 40*40*20 - - - - -
9G1224H402 | Sanyo Denki 24VDC 4.08W DC Axial Fan for UPS, server and telecom equipment cooling

The 119 × 119 × 25 mm Sanyo Denki 9G1224H402 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Use the documented mounting size when planning power-budget planning. Obtain the applicable curve before final duty-point approval. Focus: resistance curve checking.

24 119*119*25 149.6 64 4.08 2850 40
9GA0424H3003 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

9GA0424H3003 addresses servers, UPS systems, and telecom equipment through a 24 VDC DC axial fan platform measuring 40 × 40 × 28 mm. Long-life series construction is the main characteristic stated in the supplied reference. The 40 × 40 × 28 mm format is the primary stated selection detail. Focus: resistance curve checking thermal-duty record.

24 40*40*28 - - - - -
109E5724H507 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

For servers, UPS systems, and telecom equipment, 109E5724H507 combines 24 VDC operation with a 172 × 150 × 51 mm DC axial fan design. Series focus: high airflow and pressure. The 172 × 150 × 51 mm format is the primary stated selection detail. Check resistance curve checking supply requirement. Focus: resistance curve checking supply requirement.

24 172*150*51 - - - - -
109P0412M7D01 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

Equipment designers serving servers, UPS systems, and telecom equipment can evaluate Sanyo Denki 109P0412M7D01, a DC axial fan rated at 24 VDC and sized 60 × 60 × 15 mm. The 60 × 60 × 15 mm format is the primary stated selection detail. Review its suffix definition during fan selection. Review connector, alarm, and sensor options separately.

24 60*60*15 - - - - -
9G0924A2D01 | Sanyo Denki 24VDC 7.2W DC Axial Fan for UPS, server and telecom equipment cooling

The 92 × 92 × 32 mm Sanyo Denki 9G0924A2D01 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Base wiring review on the stated electrical load. Review connector, alarm, and sensor options separately. Focus: resistance curve checking sound level.

24 92*92*32 150 115 7.2 4300 44
Showing
361-380
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-816
of 816
1 2 ... 16 17 18 19 20 21 22 ... 40 41
GO page

About Data Center Cooling

Data center cooling fans are specialized ventilation components engineered to maintain the precise temperature and humidity requirements of modern computing infrastructure. As data centers grow in density with higher TDP processors and accelerated adoption of AI and HPC workloads, cooling fan performance and energy efficiency have become critical operational concerns. Data center cooling fans serve three primary architectural roles: server-level fans (120mm DC axial fans mounted in server chassis for direct component cooling), rack-level cooling (inline or roof-mounted EC fans for hot-aisle containment systems), and facility-level HVAC fans (air handling units with EC backward curved centrifugal blowers for building-wide circulation). Key design requirements for data center fans include: reliability (MTBF typically exceeding 100,000 hours), quiet operation (dBA levels for occupied spaces), EC technology for energy efficiency and variable speed, PWM or Modbus control for intelligent thermal management, and hot-swap capability for critical systems. Leading manufacturers include ebm-papst, ZIEHL-ABEGG, Rosenberg, Sanyo Denki, and SUNON. Hengrui supplies data center cooling fans with cross-reference tools, competitive pricing, and engineering consultation.

How to Select the Right Data Center Cooling

The most reliable way to specify data Center Cooling is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.

Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.

Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.

End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 816 products are available in this category today.

Typical Applications and Use Cases for Data Center Cooling

The daily work of our sales engineers is built around data Center Cooling used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.

A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.

Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.

From one-piece emergency replacements to volume supply for equipment manufacturers, every enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.

Frequently Asked Questions About Buying Data Center Cooling

What technical documentation do you provide before purchase?

Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.

Do you have data Center Cooling in stock and how fast can you deliver?

Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 816 products in this category are listed online.

Can you replace my existing data Center Cooling from another supplier or a discontinued model?

Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.

Bag

Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.