1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-816
of 816
Download Table
Mfr Part # Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
9G0824G101 | Sanyo Denki 24VDC 13.4W DC Axial Fan for UPS, server and telecom equipment cooling

The 80 × 80 × 38 mm Sanyo Denki 9G0824G101 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. During procurement comparison, compare the model's operating point. Match the exact part number before approving a substitute. Focus: acoustic limit assessment sound level.

24 80*80*38 153 211 13.4 6300 51
109P0412J301 | Sanyo Denki 12VDC DC Axial Fan for UPS, server and telecom equipment cooling

109P0412J301 addresses servers, UPS systems, and telecom equipment through a 12 VDC DC axial fan platform measuring 40 × 40 × 28 mm. Series focus: high airflow and pressure. 12500 rpm is the model's most prominent operating value. Check acoustic limit assessment rotational rating. Focus: acoustic limit assessment rotational rating.

12 40*40*28 - - - 12500 44
109E4724H401 | Sanyo Denki 24VDC 24W DC Axial Fan for UPS, server and telecom equipment cooling

The 109E4724H401 is a Sanyo Denki 24 VDC, φ172 × 25 mm DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. During power-budget planning, compare the model's suffix definition. Review connector, alarm, and sensor options separately. Focus: acoustic limit assessment power demand.

24 φ172*25 384 135 24 3400 57
109E5724K501 | Sanyo Denki 24VDC 31.2W DC Axial Fan for UPS, server and telecom equipment cooling

The 172 × 150 × 51 mm Sanyo Denki 109E5724K501 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. The recorded motor input should guide airflow-path design. Check the full suffix before confirming connector details.

24 172*150*51 510 243 31.2 4100 60
9G1224A401 | Sanyo Denki 24VDC 5.04W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki 9G1224A401 is a 24 VDC DC axial fan in a 120 × 120 × 25 mm format for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Its listed airflow of 170 m³/h is the standout performance value. Check acoustic limit assessment operating point. Focus: acoustic limit assessment operating point.

24 120*120*25 170 - 5.04 3150 44
9G1212H101 | Sanyo Denki 12VDC 4.56W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki configures 9G1212H101 for servers, UPS systems, and telecom equipment as a 12 VDC DC axial fan with 120 × 120 × 38 mm dimensions. Its 2600 rpm rating defines a lower-speed operating point. Base service-life planning on the stated catalog specification. Confirm control inputs against the complete ordering code.

12 120*120*38 168.3 70.5 4.56 2600 39
109P0424H6D14 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

A 40 × 40 × 20 mm frame and 24 VDC rating define 109P0424H6D14, a DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. The 40 × 40 × 20 mm format is the primary stated selection detail. Check acoustic limit assessment dimensional envelope. Focus: acoustic limit assessment dimensional envelope.

24 40*40*20 - - - - -
109P0424D601 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

109P0424D601 serves servers, UPS systems, and telecom equipment as a 40 × 40 × 20 mm DC axial fan rated at 24 VDC. Series focus: high airflow and pressure. The 40 × 40 × 20 mm format is the primary stated selection detail. Check acoustic limit assessment acoustic value. Focus: acoustic limit assessment acoustic value.

24 40*40*20 - - - - -
9A0812H402 | Sanyo Denki 12VDC 1.56W DC Axial Fan for UPS, server and telecom equipment cooling

9A0812H402 serves servers, UPS systems, and telecom equipment as a 80 × 80 × 25 mm DC axial fan rated at 12 VDC. Series focus: high airflow and pressure. A listed input of 1.56 W is the notable efficiency-related parameter. Check acoustic limit assessment electrical load. Focus: acoustic limit assessment electrical load.

12 80*80*25 61.88 35.4 1.56 2900 29
109P0424H3013 | Sanyo Denki 24VDC 2.28W DC Axial Fan for UPS, server and telecom equipment cooling

The 40 × 40 × 28 mm Sanyo Denki 109P0424H3013 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Review its thermal-duty record during thermal validation. Match the exact part number before approving a substitute. Focus: acoustic limit assessment speed benchmark.

24 40*40*28 19.21 102.9 2.28 8700 37
9G0924G101 | Sanyo Denki 24VDC 13.2W DC Axial Fan for UPS, server and telecom equipment cooling

The 9G0924G101 is a Sanyo Denki 24 VDC, 92 × 92 × 38 mm DC axial fan for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. During enclosure sizing, compare the model's acoustic value. Treat bearing and life data as suffix-specific. Focus: acoustic limit assessment airflow profile.

24 92*92*38 187 149.9 13.2 5000 50
9G1224H101 | Sanyo Denki 24VDC 5.28W DC Axial Fan for UPS, server and telecom equipment cooling

For thermal management in servers, UPS systems, and telecom equipment, the 9G1224H101 provides a 24 VDC DC axial fan configuration measuring 120 × 120 × 38 mm. Its 2600 rpm rating defines a lower-speed operating point. Treat the motor input as a primary input to mounting verification. Validate mounting and wiring from the model drawing.

24 120*120*38 168 70.4 5.28 2600 39
9GA0412P3K01 | Sanyo Denki 12VDC 11.04W DC Axial Fan for UPS, server and telecom equipment cooling

9GA0412P3K01 addresses servers, UPS systems, and telecom equipment through a 12 VDC DC axial fan platform measuring 40 × 40 × 28 mm. Long-life series construction is the main characteristic stated in the supplied reference. 22000 rpm is the model's most prominent operating value. Selection focus: power budget review installation footprint.

12 40*40*28 49 799 11.04 22000 61
109E1248H182 | Sanyo Denki 48VDC DC Axial Fan for UPS, server and telecom equipment cooling

The 120 × 120 × 38 mm Sanyo Denki 109E1248H182 brings 48 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Review its rated dataset during cooling-margin review. Check the full suffix before confirming connector details. Focus: power budget review selection parameters.

48 120*120*38 - - - - -
109P0412H901 | Sanyo Denki 12VDC 0.84W DC Axial Fan for UPS, server and telecom equipment cooling

Equipment designers serving servers, UPS systems, and telecom equipment can evaluate Sanyo Denki 109P0412H901, a DC axial fan rated at 12 VDC and sized 40 × 40 × 10 mm. The 9.01 m³/h airflow figure supports its stated equipment-cooling role. Base service-life planning on the stated cooling output. Treat bearing and life data as suffix-specific.

12 40*40*10 9.01 41.1 0.84 6200 25
9G1224H1D01 | Sanyo Denki 24VDC 5.28W DC Axial Fan for UPS, server and telecom equipment cooling

The 119 × 119 × 38 mm Sanyo Denki 9G1224H1D01 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. The recorded frame geometry should guide mounting verification. Verify the exact bearing and signal options in the datasheet. Focus: power budget review motor input.

24 119*119*38 168.3 70.5 5.28 2600 39
109E2024S002 | Sanyo Denki 24VDC 45.6W DC Axial Fan for UPS, server and telecom equipment cooling

The φ200 × 70 mm Sanyo Denki 109E2024S002 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. For spares assessment, start with the supplied selection parameters. Use the latest specification for frequency and tolerance limits.

24 φ200*70 627.3 287.1 45.6 3200 57
109P0624S7D03 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

The 24 VDC Sanyo Denki 109P0624S7D03 is a DC axial fan sized 60 × 60 × 15 mm for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. The 60 × 60 × 15 mm format is the primary stated selection detail. Check power budget review catalog specification. Focus: power budget review catalog specification.

24 60*60*15 - - - - -
109R0624J4D01 | Sanyo Denki 24VDC 5.76W DC Axial Fan for UPS, server and telecom equipment cooling

The 109R0624J4D01 is a Sanyo Denki 24 VDC, 60 × 60 × 25 mm DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Base spares assessment on the stated static-pressure entry. Check the full suffix before confirming connector details. Focus: power budget review performance curve.

24 60*60*25 63.07 155 5.76 7600 44
109P0412G6D01 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

For servers, UPS systems, and telecom equipment, 109P0412G6D01 combines 24 VDC operation with a size not stated DC axial fan design. Series focus: high airflow and pressure. The size not stated format is the primary stated selection detail. Check power budget review mounting size. Focus: power budget review mounting size.

24 - - - - - -
Showing
341-360
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-816
of 816
1 2 ... 15 16 17 18 19 20 21 ... 40 41
GO page

About Data Center Cooling

Data center cooling fans are specialized ventilation components engineered to maintain the precise temperature and humidity requirements of modern computing infrastructure. As data centers grow in density with higher TDP processors and accelerated adoption of AI and HPC workloads, cooling fan performance and energy efficiency have become critical operational concerns. Data center cooling fans serve three primary architectural roles: server-level fans (120mm DC axial fans mounted in server chassis for direct component cooling), rack-level cooling (inline or roof-mounted EC fans for hot-aisle containment systems), and facility-level HVAC fans (air handling units with EC backward curved centrifugal blowers for building-wide circulation). Key design requirements for data center fans include: reliability (MTBF typically exceeding 100,000 hours), quiet operation (dBA levels for occupied spaces), EC technology for energy efficiency and variable speed, PWM or Modbus control for intelligent thermal management, and hot-swap capability for critical systems. Leading manufacturers include ebm-papst, ZIEHL-ABEGG, Rosenberg, Sanyo Denki, and SUNON. Hengrui supplies data center cooling fans with cross-reference tools, competitive pricing, and engineering consultation.

How to Select the Right Data Center Cooling

The most reliable way to specify data Center Cooling is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.

Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.

Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.

End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 816 products are available in this category today.

Typical Applications and Use Cases for Data Center Cooling

The daily work of our sales engineers is built around data Center Cooling used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.

A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.

Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.

From one-piece emergency replacements to volume supply for equipment manufacturers, every enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.

Frequently Asked Questions About Buying Data Center Cooling

What technical documentation do you provide before purchase?

Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.

Do you have data Center Cooling in stock and how fast can you deliver?

Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 816 products in this category are listed online.

Can you replace my existing data Center Cooling from another supplier or a discontinued model?

Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.

Bag

Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.