Get Quote
Home > Products > By industry > Data Center Cooling

Data Center Cooling

By brand

By type

Rated Voltage(V)

Size(mm)

Max.Air Flow(m³/h)

Max.Pressure(Pa)

Input Power(W)

Speed(rpm)

Noise(db)

Stocking Options

Environmental Options

Media

Exclude

816 results

Applied Filters

Showing
281-300
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-816
of 816
Download Table
Mfr Part # Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
109E5724H502 | Sanyo Denki 24VDC 13.92W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki configures 109E5724H502 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 172 × 150 × 51 mm dimensions. Its listed airflow of 384 m³/h is the standout performance value. Base power-budget planning on the stated operating point. Validate mounting and wiring from the model drawing.

24 172*150*51 384 137.2 13.92 3050 52
109P0612H701 | Sanyo Denki 12VDC 1.08W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki 109P0612H701 combines a 60 × 60 × 15 mm DC axial fan platform with a 12 VDC rating for servers, UPS systems, and telecom equipment. The supplied reference emphasizes high static pressure and high airflow. A listed input of 1.08 W is the notable efficiency-related parameter. Selection focus: control interface planning frame geometry.

12 60*60*15 23.7 38.2 1.08 4100 32
109P0424H301 | Sanyo Denki 24VDC 2.28W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki configures 109P0424H301 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 40 × 40 × 28 mm dimensions. 8700 rpm is the model's most prominent operating value. Review its rotational rating during spares assessment. Validate mounting and wiring from the model drawing. Focus: control interface planning.

24 40*40*28 - - 2.28 8700 37
109R0612G402 | Sanyo Denki 12VDC 2.88W DC Axial Fan for UPS, server and telecom equipment cooling

The 60 × 60 × 25 mm Sanyo Denki 109R0612G402 brings 12 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. Treat the cooling specification as a primary input to cabinet ventilation planning. Treat bearing and life data as suffix-specific.

12 60*60*25 46.2 87.3 2.88 5600 39
9GA0612P6S001 | Sanyo Denki 12VDC 1.8W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki configures 9GA0612P6S001 for servers, UPS systems, and telecom equipment as a 12 VDC DC axial fan with 60 × 60 × 20 mm dimensions. A listed input of 1.8 W is the notable efficiency-related parameter. For cooling-margin review, start with the supplied motor input. Review connector, alarm, and sensor options separately.

12 60*60*20 42 81 1.8 5500 36
9A0612G4D011 | Sanyo Denki 12VDC 2.88W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki 9A0612G4D011 combines a 60 × 60 × 25 mm DC axial fan platform with a 12 VDC rating for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. A listed input of 2.88 W is the notable efficiency-related parameter. Selection focus: control interface planning acoustic value.

12 60*60*25 46.4 87.3 2.88 5600 39
9GA0312P3K001 | Sanyo Denki 12VDC 7.4W DC Axial Fan for UPS, server and telecom equipment cooling

For servers, UPS systems, and telecom equipment, 9GA0312P3K001 combines 12 VDC operation with a 38 × 38 × 28 mm DC axial fan design. Long-life series construction is the main characteristic stated in the supplied reference. 25000 rpm is the model's most prominent operating value. Selection focus: control interface planning electrical load.

12 38*38*28 36 800 7.4 25000 59
9GA0412P7G001 | Sanyo Denki 12VDC 2.04W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki 9GA0412P7G001 combines a 40 × 40 × 15 mm DC axial fan platform with a 12 VDC rating for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. The 22 m³/h airflow figure supports its stated equipment-cooling role. Focus: control interface planning.

12 40*40*15 22 192 2.04 13100 42
109R0824L401 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki 109R0824L401 is a 24 VDC DC axial fan in a 80 × 80 × 25 mm format for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. 14.7 Pa maximum pressure is the most distinctive duty-point parameter. Check mounting geometry validation system interface. Focus: mounting geometry validation system interface.

24 80*80*25 38.6 14.7 - 1850 20
9A0924S402 | Sanyo Denki 24VDC 3.6W DC Axial Fan for UPS, server and telecom equipment cooling

A 92 × 92 × 25 mm frame and 24 VDC rating define 9A0924S402, a DC axial fan for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. 56 Pa maximum pressure is the most distinctive duty-point parameter. Check mounting geometry validation cooling specification.

24 92*92*25 98.4 56 3.6 3550 39
9A0924M4D01 | Sanyo Denki 24VDC 1.2W DC Axial Fan for UPS, server and telecom equipment cooling

For thermal management in servers, UPS systems, and telecom equipment, the 9A0924M4D01 provides a 24 VDC DC axial fan configuration measuring 92 × 92 × 25 mm. Its 2250 rpm rating defines a lower-speed operating point. The recorded suffix definition should guide equipment integration. Use the latest specification for frequency and tolerance limits.

24 92*92*25 61.8 22.7 1.2 2250 27
109P0624H601 | Sanyo Denki 24VDC 1.68W DC Axial Fan for UPS, server and telecom equipment cooling

The 60 × 60 × 20 mm Sanyo Denki 109P0624H601 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. During wiring review, compare the model's dimensional envelope. Obtain the applicable curve before final duty-point approval. Focus: mounting geometry validation.

24 60*60*20 24.8 31.8 1.68 4200 31
109P0824H701 | Sanyo Denki 24VDC 2.4W DC Axial Fan for UPS, server and telecom equipment cooling

The 109P0824H701 is a Sanyo Denki 24 VDC, 80 × 80 × 15 mm DC axial fan for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. The recorded pressure capability should guide maintenance preparation. Confirm environmental protection for the ordered version.

24 80*80*15 53.9 29.4 2.4 3100 31
9G1212G1021 | Sanyo Denki 12VDC 11.76W DC Axial Fan for UPS, server and telecom equipment cooling

The 120 × 120 × 38 mm Sanyo Denki 9G1212G1021 brings 12 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. For procurement comparison, start with the supplied frame geometry. Validate mounting and wiring from the model drawing. Focus: mounting geometry validation rated dataset.

12 120*120*38 230.4 135 11.76 3600 49
109E5724H509 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

109E5724H509 addresses servers, UPS systems, and telecom equipment through a 24 VDC DC axial fan platform measuring 172 × 150 × 51 mm. Series focus: high airflow and pressure. The 172 × 150 × 51 mm format is the primary stated selection detail. Check mounting geometry validation motor input. Focus: mounting geometry validation motor input.

24 172*150*51 - - - - -
109R1224H102 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki configures 109R1224H102 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 120 × 120 × 38 mm dimensions. The 120 × 120 × 38 mm format is the primary stated selection detail. Base power-budget planning on the stated equipment fit. Review connector, alarm, and sensor options separately.

24 120*120*38 - - - - -
9G1224E1D01 | Sanyo Denki 24VDC 8.16W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki configures 9G1224E1D01 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 120 × 120 × 38 mm dimensions. 0 Pa maximum pressure is the most distinctive duty-point parameter. Treat the sound level as a primary input to system-resistance review. Confirm environmental protection for the ordered version.

24 120*120*38 200.6 0 8.16 3100 46
9G1224H4021 | Sanyo Denki 24VDC 4.08W DC Axial Fan for UPS, server and telecom equipment cooling

The 24 VDC Sanyo Denki 9G1224H4021 is a DC axial fan sized 119 × 119 × 25 mm for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. Its 2850 rpm rating defines a lower-speed operating point. Check mounting geometry validation catalog specification.

24 119*119*25 147.6 64 4.08 2850 40
109R0612J4D01 | Sanyo Denki 12VDC 5.64W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki configures 109R0612J4D01 for servers, UPS systems, and telecom equipment as a 12 VDC DC axial fan with 60 × 60 × 25 mm dimensions. 7600 rpm is the model's most prominent operating value. Use the documented airflow profile when planning spares assessment. Treat bearing and life data as suffix-specific.

12 60*60*25 62.4 155 5.64 7600 44
9G1212H1D01 | Sanyo Denki 12VDC 4.56W DC Axial Fan for UPS, server and telecom equipment cooling

For thermal management in servers, UPS systems, and telecom equipment, the 9G1212H1D01 provides a 12 VDC DC axial fan configuration measuring 120 × 120 × 38 mm. Its 2600 rpm rating defines a lower-speed operating point. Review its catalog specification during power-budget planning. Obtain the applicable curve before final duty-point approval.

12 120*120*38 168.13 - 4.56 2600 39
Showing
281-300
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-816
of 816
1 2 ... 12 13 14 15 16 17 18 ... 40 41
GO page

About Data Center Cooling

Data center cooling fans are specialized ventilation components engineered to maintain the precise temperature and humidity requirements of modern computing infrastructure. As data centers grow in density with higher TDP processors and accelerated adoption of AI and HPC workloads, cooling fan performance and energy efficiency have become critical operational concerns. Data center cooling fans serve three primary architectural roles: server-level fans (120mm DC axial fans mounted in server chassis for direct component cooling), rack-level cooling (inline or roof-mounted EC fans for hot-aisle containment systems), and facility-level HVAC fans (air handling units with EC backward curved centrifugal blowers for building-wide circulation). Key design requirements for data center fans include: reliability (MTBF typically exceeding 100,000 hours), quiet operation (dBA levels for occupied spaces), EC technology for energy efficiency and variable speed, PWM or Modbus control for intelligent thermal management, and hot-swap capability for critical systems. Leading manufacturers include ebm-papst, ZIEHL-ABEGG, Rosenberg, Sanyo Denki, and SUNON. Hengrui supplies data center cooling fans with cross-reference tools, competitive pricing, and engineering consultation.

How to Select the Right Data Center Cooling

The most reliable way to specify data Center Cooling is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.

Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.

Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.

End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 816 products are available in this category today.

Typical Applications and Use Cases for Data Center Cooling

The daily work of our sales engineers is built around data Center Cooling used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.

A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.

Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.

From one-piece emergency replacements to volume supply for equipment manufacturers, every enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.

Frequently Asked Questions About Buying Data Center Cooling

What technical documentation do you provide before purchase?

Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.

Do you have data Center Cooling in stock and how fast can you deliver?

Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 816 products in this category are listed online.

Can you replace my existing data Center Cooling from another supplier or a discontinued model?

Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.

Bag

Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.