Get Quote
Home > Products > By industry > Data Center Cooling

Data Center Cooling

By brand

By type

Rated Voltage(V)

Size(mm)

Max.Air Flow(m³/h)

Max.Pressure(Pa)

Input Power(W)

Speed(rpm)

Noise(db)

Stocking Options

Environmental Options

Media

Exclude

816 results

Applied Filters

Showing
261-280
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-816
of 816
Download Table
Mfr Part # Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
9GA0612P6G001 | Sanyo Denki 12VDC 3.12W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki 9GA0612P6G001 combines a 60 × 60 × 20 mm DC axial fan platform with a 12 VDC rating for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. 6850 rpm is the model's most prominent operating value. Selection focus: wiring scheme review supply requirement.

12 60*60*20 53 125 3.12 6850 43
109P0524H7D01 | Sanyo Denki 24VDC 1.2W DC Axial Fan for UPS, server and telecom equipment cooling

109P0524H7D01 addresses servers, UPS systems, and telecom equipment through a 24 VDC DC axial fan platform measuring 52 × 52 × 15 mm. Series focus: high airflow and pressure. The 15.1 m³/h airflow figure supports its stated equipment-cooling role. Check wiring scheme review static-pressure entry. Focus: wiring scheme review static-pressure entry.

24 52*52*15 15.1 31.8 1.2 4600 27
9GA0412P3G01 | Sanyo Denki 12VDC 4.68W DC Axial Fan for UPS, server and telecom equipment cooling

9GA0412P3G01 addresses servers, UPS systems, and telecom equipment through a 12 VDC DC axial fan platform measuring 40 × 40 × 28 mm. Long-life series construction is the main characteristic stated in the supplied reference. 16500 rpm is the model's most prominent operating value. Selection focus: wiring scheme review volume-flow figure.

12 40*40*28 37 450 4.68 16500 53
9A0624S402 | Sanyo Denki 24VDC 1.92W DC Axial Fan for UPS, server and telecom equipment cooling

Within servers, UPS systems, and telecom equipment, 9A0624S402 provides a 60 × 60 × 25 mm, 24 VDC DC axial fan configuration. The supplied reference emphasizes high static pressure and high airflow. A listed input of 1.92 W is the notable efficiency-related parameter. Check wiring scheme review sound level. Focus: wiring scheme review sound level.

24 60*60*25 38.6 56.8 1.92 4600 33
9G0824G102 | Sanyo Denki 24VDC 13.4W DC Axial Fan for UPS, server and telecom equipment cooling

For thermal management in servers, UPS systems, and telecom equipment, the 9G0824G102 provides a 24 VDC DC axial fan configuration measuring 80 × 80 × 38 mm. 13.4 W input is the defining electrical-load figure. Base airflow-path design on the stated system interface. Match the exact part number before approving a substitute.

24 80*80*38 151.2 211 13.4 6300 51
9G1224E101 | Sanyo Denki 24VDC 8.16W DC Axial Fan for UPS, server and telecom equipment cooling

9G1224E101 serves servers, UPS systems, and telecom equipment as a 119 × 119 × 38 mm DC axial fan rated at 24 VDC. High airflow is highlighted together with a high-static-pressure design. Its listed airflow of 201 m³/h is the standout performance value. Check wiring scheme review frame geometry. Selection focus: wiring scheme review frame geometry.

24 119*119*38 201 100 8.16 3100 46
109E1724M501 | Sanyo Denki 24VDC 4.8W DC Axial Fan for UPS, server and telecom equipment cooling

109E1724M501 addresses servers, UPS systems, and telecom equipment through a 24 VDC DC axial fan platform measuring ø172 × 51 mm. High airflow is highlighted together with a high-static-pressure design. Its 2000 rpm rating defines a lower-speed operating point. Check wiring scheme review cooling output. Focus: wiring scheme review cooling output.

24 ø172*51 251.6 67.6 4.8 2000 36
109P0424N7D04 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

109P0424N7D04 serves servers, UPS systems, and telecom equipment as a size not stated DC axial fan rated at 24 VDC. The supplied reference emphasizes high static pressure and high airflow. The size not stated format is the primary stated selection detail. Check wiring scheme review operating point. Focus: wiring scheme review operating point.

24 - - - - - -
109P0424H3D19 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

109P0424H3D19 serves servers, UPS systems, and telecom equipment as a 40 × 40 × 28 mm DC axial fan rated at 24 VDC. Series focus: high airflow and pressure. The 40 × 40 × 28 mm format is the primary stated selection detail. Check wiring scheme review pressure capability. Focus: wiring scheme review pressure capability.

24 40*40*28 - - - - -
9G1212E101 | Sanyo Denki 12VDC 7.32W DC Axial Fan for UPS, server and telecom equipment cooling

A 120 × 120 × 38 mm frame and 12 VDC rating define 9G1212E101, a DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Its listed airflow of 200.6 m³/h is the standout performance value. Check wiring scheme review airflow profile. Focus: wiring scheme review airflow profile.

12 120*120*38 200.6 - 7.32 3100 46
9G1224G1D011 | Sanyo Denki 24VDC 12W DC Axial Fan for UPS, server and telecom equipment cooling

For servers, UPS systems, and telecom equipment, 9G1224G1D011 combines 24 VDC operation with a 120 × 120 × 38 mm DC axial fan design. Series focus: high airflow and pressure. Its listed airflow of 233 m³/h is the standout performance value. Check control interface planning system interface. Focus: control interface planning system interface.

24 120*120*38 233 - 12 3600 49
9RA0912P1J001 | Sanyo Denki 12VDC 14.9W DC Axial Fan for UPS, server and telecom equipment cooling

The 12 VDC Sanyo Denki 9RA0912P1J001 is a DC axial fan sized 92 × 92 × 38 mm for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. 14.9 W input is the defining electrical-load figure. Check control interface planning cooling specification. Focus: control interface planning.

12 92*92*38 198.9 192 14.9 6400 50
9GA0612M6001 | Sanyo Denki 12VDC 0.6W DC Axial Fan for UPS, server and telecom equipment cooling

9GA0612M6001 addresses servers, UPS systems, and telecom equipment through a 12 VDC DC axial fan platform measuring 60 × 60 × 20 mm. Long-life series construction is the main characteristic stated in the supplied reference. A listed input of 0.6 W is the notable efficiency-related parameter. Focus: control interface planning duty-point values.

12 60*60*20 20.4 20 0.6 2700 18
109R0824G4D01 | Sanyo Denki 24VDC 4.8W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki 109R0824G4D01 combines a 80 × 80 × 25 mm DC axial fan platform with a 24 VDC rating for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. 80.4 Pa maximum pressure is the most distinctive duty-point parameter. Focus: control interface planning installation footprint.

24 80*80*25 90.1 80.4 4.8 4500 40
109P0424G302 | Sanyo Denki 24VDC 4.56W DC Axial Fan for UPS, server and telecom equipment cooling

The 24 VDC Sanyo Denki 109P0424G302 is a DC axial fan sized 40 × 40 × 28 mm for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. The 25.16 m³/h airflow figure supports its stated equipment-cooling role. Check control interface planning rated dataset.

24 40*40*28 25.16 - 4.56 11500 42
9SG1224H101 | Sanyo Denki 24VDC 11W DC Axial Fan for UPS, server and telecom equipment cooling

9SG1224H101 addresses servers, UPS systems, and telecom equipment through a 24 VDC DC axial fan platform measuring 119 × 119 × 38 mm. High airflow is highlighted together with a high-static-pressure design. Its listed airflow of 238.8 m³/h is the standout performance value. Check control interface planning motor input.

24 119*119*38 238.8 127 11 3400 48
109P0424G301 | Sanyo Denki 24VDC 4.56W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki configures 109P0424G301 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 40 × 40 × 28 mm dimensions. 11500 rpm is the model's most prominent operating value. Treat the operating point as a primary input to cabinet ventilation planning. Validate mounting and wiring from the model drawing.

24 40*40*28 - - 4.56 11500 42
109R0624S402 | Sanyo Denki 24VDC 1.92W DC Axial Fan for UPS, server and telecom equipment cooling

The 24 VDC Sanyo Denki 109R0624S402 is a DC axial fan sized 60 × 60 × 25 mm for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. A listed input of 1.92 W is the notable efficiency-related parameter. Check control interface planning equipment fit. Focus: control interface planning equipment fit.

24 60*60*25 38.6 56.8 1.92 4600 33
109P0524A7D03 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

Equipment designers serving servers, UPS systems, and telecom equipment can evaluate Sanyo Denki 109P0524A7D03, a DC axial fan rated at 24 VDC and sized 50 × 50 × 15 mm. The 50 × 50 × 15 mm format is the primary stated selection detail. Review its motor input during spares assessment. Match the exact part number before approving a substitute.

24 50*50*15 - - - - -
109E1724K501 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

Within servers, UPS systems, and telecom equipment, 109E1724K501 provides a 172φ × 51 mm, 24 VDC DC axial fan configuration. High airflow is highlighted together with a high-static-pressure design. The 172φ × 51 mm format is the primary stated selection detail. Check control interface planning sound level. Focus: control interface planning.

24 172φ*51 - - - - -
Showing
261-280
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-816
of 816
1 2 ... 11 12 13 14 15 16 17 ... 40 41
GO page

About Data Center Cooling

Data center cooling fans are specialized ventilation components engineered to maintain the precise temperature and humidity requirements of modern computing infrastructure. As data centers grow in density with higher TDP processors and accelerated adoption of AI and HPC workloads, cooling fan performance and energy efficiency have become critical operational concerns. Data center cooling fans serve three primary architectural roles: server-level fans (120mm DC axial fans mounted in server chassis for direct component cooling), rack-level cooling (inline or roof-mounted EC fans for hot-aisle containment systems), and facility-level HVAC fans (air handling units with EC backward curved centrifugal blowers for building-wide circulation). Key design requirements for data center fans include: reliability (MTBF typically exceeding 100,000 hours), quiet operation (dBA levels for occupied spaces), EC technology for energy efficiency and variable speed, PWM or Modbus control for intelligent thermal management, and hot-swap capability for critical systems. Leading manufacturers include ebm-papst, ZIEHL-ABEGG, Rosenberg, Sanyo Denki, and SUNON. Hengrui supplies data center cooling fans with cross-reference tools, competitive pricing, and engineering consultation.

How to Select the Right Data Center Cooling

The most reliable way to specify data Center Cooling is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.

Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.

Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.

End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 816 products are available in this category today.

Typical Applications and Use Cases for Data Center Cooling

The daily work of our sales engineers is built around data Center Cooling used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.

A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.

Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.

From one-piece emergency replacements to volume supply for equipment manufacturers, every enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.

Frequently Asked Questions About Buying Data Center Cooling

What technical documentation do you provide before purchase?

Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.

Do you have data Center Cooling in stock and how fast can you deliver?

Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 816 products in this category are listed online.

Can you replace my existing data Center Cooling from another supplier or a discontinued model?

Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.

Bag

Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.