| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() 9RA0824M4001 | Sanyo Denki 24VDC 0.96W DC Axial Fan for UPS, server and telecom equipment cooling The 80 × 80 × 25 mm Sanyo Denki 9RA0824M4001 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. For thermal validation, start with the supplied volume-flow figure. Use current model documentation to validate protection choices. |
24 | 80*80*25 | 44.37 | 22.4 | 0.96 | 2650 | 22 | |
![]() 109R0612S401 | Sanyo Denki 12VDC 2.04W DC Axial Fan for UPS, server and telecom equipment cooling The 60 × 60 × 25 mm Sanyo Denki 109R0612S401 brings 12 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Review its suffix definition during controller selection. Match the exact part number before approving a substitute. Focus: cabinet ventilation planning power demand. |
12 | 60*60*25 | 38.6 | 56.8 | 2.04 | 4600 | 33 | |
![]() 9GA0612P7G01 | Sanyo Denki 12VDC 1.92W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki configures 9GA0612P7G01 for servers, UPS systems, and telecom equipment as a 12 VDC DC axial fan with 60 × 60 × 15 mm dimensions. A listed input of 1.92 W is the notable efficiency-related parameter. Treat the suffix definition as a primary input to service-life planning. Use the latest specification for frequency and tolerance limits. |
12 | 60*60*15 | 41 | 80 | 1.92 | 5900 | 38 | |
![]() 109P0612S701 | Sanyo Denki 12VDC 1.8W DC Axial Fan for UPS, server and telecom equipment cooling Within servers, UPS systems, and telecom equipment, 109P0612S701 provides a 60 × 60 × 15 mm, 12 VDC DC axial fan configuration. High airflow is highlighted together with a high-static-pressure design. A listed input of 1.8 W is the notable efficiency-related parameter. Check cabinet ventilation planning cooling output. |
12 | 60*60*15 | 28.9 | 58.8 | 1.8 | 5000 | 36 | |
![]() 9RA0612P4J001 | Sanyo Denki 12VDC 4.2W DC Axial Fan for UPS, server and telecom equipment cooling The 60 × 60 × 25 mm Sanyo Denki 9RA0612P4J001 brings 12 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. The recorded power demand should guide maintenance preparation. Review connector, alarm, and sensor options separately. |
12 | 60*60*25 | 65.96 | 129.5 | 4.2 | 7700 | 41 | |
![]() 9GA0424P6H001 | Sanyo Denki 24VDC 1.92W DC Axial Fan for UPS, server and telecom equipment cooling Sized for servers, UPS systems, and telecom equipment, Sanyo Denki 9GA0424P6H001 is a 24 VDC DC axial fan in a 40 × 40 × 20 mm frame. The 20 m³/h airflow figure supports its stated equipment-cooling role. Long-life series construction is the main characteristic stated in the supplied reference. Focus: cabinet ventilation planning. |
24 | 40*40*20 | 20 | 191 | 1.92 | 12400 | 40 | |
![]() 9GA0912P4S031 | Sanyo Denki 12VDC 2.4W DC Axial Fan for UPS, server and telecom equipment cooling The 92 × 92 × 25 mm Sanyo Denki 9GA0912P4S031 brings 12 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. For spares assessment, start with the supplied performance curve. Confirm environmental protection for the ordered version. |
12 | 92*92*25 | 99 | 59.8 | 2.4 | 3800 | 35 | |
![]() 9GA0824H4002 | Sanyo Denki 24VDC 2.4W DC Axial Fan for UPS, server and telecom equipment cooling The 9GA0824H4002 is a Sanyo Denki 24 VDC, 80 × 80 × 25.2 mm DC axial fan for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. During spares assessment, compare the model's pressure capability. Review connector, alarm, and sensor options separately. |
24 | 80*80*25.2 | 86.4 | 87.2 | 2.4 | 5200 | 37 | |
![]() 9RA0824H4002 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling For servers, UPS systems, and telecom equipment, 9RA0824H4002 combines 24 VDC operation with a 80 × 80 × 25 mm DC axial fan design. High airflow is highlighted together with a high-static-pressure design. The 80 × 80 × 25 mm format is the primary stated selection detail. Check cabinet ventilation planning electrical load. |
24 | 80*80*25 | - | - | - | - | - | |
![]() 9LB1424S5J80 | Sanyo Denki 24VDC DC Axial Fan for telecommunications equipment cooling Sanyo Denki configures 9LB1424S5J80 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 140 × 140 × 51 mm dimensions. The 140 × 140 × 51 mm format is the primary stated selection detail. Review its system interface during replacement evaluation. Treat bearing and life data as suffix-specific. |
24 | 140*140*51 | - | - | - | - | - | |
![]() 9GA0824P2S001 | Sanyo Denki 24VDC 10.1W DC Axial Fan for UPS, server and telecom equipment cooling Built around servers, UPS systems, and telecom equipment, Sanyo Denki 9GA0824P2S001 is a 24 VDC DC axial fan in a 80 × 80 × 32 mm frame. 361.2 Pa maximum pressure is the most distinctive duty-point parameter. Long-life series construction is the main characteristic stated in the supplied reference. Focus: cabinet ventilation planning. |
24 | 80*80*32 | 147.05 | 361.2 | 10.1 | 9700 | 57 | |
![]() 9A0924F402 | Sanyo Denki 24VDC 1.92W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki 9A0924F402 is a 24 VDC DC axial fan in a 92 × 92 × 25 mm format for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Its 2650 rpm rating defines a lower-speed operating point. Check equipment integration review system interface. Focus: equipment integration review system interface. |
24 | 92*92*25 | 73.8 | 32.1 | 1.92 | 2650 | 30 | |
![]() 9GV1212P1J01 | Sanyo Denki 12VDC 36W DC Axial Fan for automation and control cabinet cooling Within industrial controls, power cabinets, and energy systems, Sanyo Denki 9GV1212P1J01 operates as a 120 × 120 × 38 mm DC axial fan at 12 VDC. High airflow is highlighted together with a high-static-pressure design. The supplied row lists 64 dB as an important acoustic selection value. Focus: equipment integration review cooling specification. |
12 | 120*120*38 | 380.8 | 361.2 | 36 | 6400 | 64 | |
![]() 9S0612F401 | Sanyo Denki 12VDC 0.96W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki configures 9S0612F401 for servers, UPS systems, and telecom equipment as a 12 VDC DC axial fan with 60 × 60 × 25 mm dimensions. A listed noise figure of 20 dB is the key differentiating parameter. Review its operating point during controller selection. Review connector, alarm, and sensor options separately. |
12 | 60*60*25 | 29.41 | 29.9 | 0.96 | 3300 | 20 | |
![]() 9WPA0624P4G001 | Sanyo Denki 24VDC 11.04W DC Axial Fan for solar inverter and energy storage cooling For thermal management in outdoor equipment and photovoltaic inverters, the 9WPA0624P4G001 provides a 24 VDC DC axial fan configuration measuring 60 × 60 × 25 mm. 12000 rpm is the model's most prominent operating value. The recorded airflow profile should guide procurement comparison. Match the exact part number before approving a substitute. |
24 | 60*60*25 | 91.2 | 357 | 11.04 | 12000 | 56 | |
![]() 9WE1724K501 | Sanyo Denki 24VDC 31.2W DC Axial Fan for solar inverter and energy storage cooling Equipment designers serving outdoor equipment and photovoltaic inverters can evaluate Sanyo Denki 9WE1724K501, a DC axial fan rated at 24 VDC and sized ø172 × 51 mm. Its listed airflow of 504 m³/h is the standout performance value. Review its pressure capability during maintenance preparation. Validate mounting and wiring from the model drawing. |
24 | ø172*51 | 504 | 241.6 | 31.2 | 4100 | 55 | |
![]() 109P0612H761 | Sanyo Denki 12VDC DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki configures 109P0612H761 for servers, UPS systems, and telecom equipment as a 12 VDC DC axial fan with 60 × 60 × 15 mm dimensions. The 60 × 60 × 15 mm format is the primary stated selection detail. The recorded ventilation capacity should guide service-life planning. Treat bearing and life data as suffix-specific. |
12 | 60*60*15 | - | - | - | - | - | |
![]() 9LB1412S5D01 | Sanyo Denki 12VDC 32.4W DC Axial Fan for telecommunications equipment cooling Designed for servers, UPS systems, and telecom equipment, Sanyo Denki 9LB1412S5D01 is a 12 VDC DC axial fan in a 140 × 140 × 51 mm frame. Its listed airflow of 480.6 m³/h is the standout performance value. Long-life series construction is the main characteristic stated in the supplied reference. Focus: equipment integration review motor input. |
12 | 140*140*51 | 480.6 | 239.1 | 32.4 | 4200 | 57 | |
![]() 9WL0412G3001 | Sanyo Denki 12VDC 4.8W DC Axial Fan for solar inverter and energy storage cooling 9WL0412G3001 serves outdoor equipment and photovoltaic inverters as a 40 × 40 × 28 mm DC axial fan rated at 12 VDC. Its oil-resistant fan design and IP68 listing is the defining supplied feature. 15500 rpm is the model's most prominent operating value. Check equipment integration review ventilation capacity. Focus: equipment integration review. |
12 | 40*40*28 | 33.1 | 308.9 | 4.8 | 15500 | 47 | |
![]() 109L0624H4J03 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling The 109L0624H4J03 is a Sanyo Denki 24 VDC, 60 × 60 × 25 mm DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Treat the equipment fit as a primary input to cabinet ventilation planning. Use current model documentation to validate protection choices. Focus: equipment integration review. |
24 | 60*60*25 | - | - | - | - | - |
The most reliable way to specify san Ace Dc Fan is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.
Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.
Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.
End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 576 products are available in this category today.
The daily work of our sales engineers is built around san Ace Dc Fan used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.
A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.
Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.
From one-piece emergency replacements to volume supply for equipment manufacturers, every Sanyo enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.
Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.
Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.
Every unit is covered by the manufacturer's warranty against defects in materials and workmanship, and we support you through the whole claim process so you deal with one supplier instead of chasing a factory overseas. If a failure appears in service, send us the serial number, operating conditions and photos, and we will arrange the replacement or credit path agreed in the quotation.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.