| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() 109R0824G401 | Sanyo Denki 24VDC 4.8W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki 109R0824G401 is a 24 VDC DC axial fan in a 80 × 80 × 25 mm format for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. 80.4 Pa maximum pressure is the most distinctive duty-point parameter. Check cooling margin validation motor input. Focus: cooling margin validation. |
24 | 80*80*25 | 90 | 80.4 | 4.8 | 4500 | 40 | |
![]() 9S1212P4H031 | Sanyo Denki 12VDC DC Axial Fan for UPS, server and telecom equipment cooling The 9S1212P4H031 is a Sanyo Denki 12 VDC, 120 × 120 × 25 mm DC axial fan for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. The recorded sound level should guide procurement comparison. Validate mounting and wiring from the model drawing. Focus: cooling margin validation. |
12 | 120*120*25 | - | - | - | - | - | |
![]() 9S1212P4H01 | Sanyo Denki 12VDC 4.68W DC Axial Fan for UPS, server and telecom equipment cooling The 12 VDC Sanyo Denki 9S1212P4H01 is a DC axial fan sized 120 × 120 × 25 mm for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Its 2700 rpm rating defines a lower-speed operating point. Check cooling margin validation equipment fit. Focus: cooling margin validation equipment fit. |
12 | 120*120*25 | 147 | 45.2 | 4.68 | 2700 | 36 | |
![]() 9GA0924P4G03 | Sanyo Denki 24VDC 3.6W DC Axial Fan for UPS, server and telecom equipment cooling The 92 × 92 × 25 mm Sanyo Denki 9GA0924P4G03 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. Review its cooling specification during cabinet ventilation planning. Obtain the applicable curve before final duty-point approval. |
24 | 92*92*25 | 116 | 81 | 3.6 | 4400 | 39 | |
![]() 9BMB24P2KD03 | Sanyo Denki 24VDC 97x33mm DC Centrifugal Blower for medical equipment cooling For thermal management in medical equipment cooling, the 9BMB24P2KD03 provides a 24 VDC DC blower configuration measuring 97 × 33 mm. The 97 × 33 mm format is the primary stated selection detail. Use the documented cooling output when planning enclosure sizing. Check the full suffix before confirming connector details. |
24 | 97*33 | - | - | - | - | - | |
![]() 9WP0824S401 | Sanyo Denki 24VDC 2.4W DC Axial Fan for solar inverter and energy storage cooling For renewable-energy power electronics, 9WP0824S401 combines 24 VDC operation with a 80 × 80 × 25 mm DC axial fan design. No exact entry appears in the supplied feature table, so bearing, control, and protection details require datasheet confirmation. 48.1 Pa maximum pressure is the most distinctive duty-point parameter. |
24 | 80*80*25 | 72.08 | 48.1 | 2.4 | 3400 | 34 | |
![]() 9GA0612P1J03 | Sanyo Denki 12VDC 18W DC Axial Fan for UPS, server and telecom equipment cooling For thermal management in servers, UPS systems, and telecom equipment, the 9GA0612P1J03 provides a 12 VDC DC axial fan configuration measuring 60 × 60 × 38 mm. 17500 rpm is the model's most prominent operating value. During maintenance preparation, compare the model's ventilation capacity. Confirm environmental protection for the ordered version. |
12 | 60*60*38 | 105 | 820 | 18 | 17500 | 63 | |
![]() 9BMB24P2K27 | Sanyo Denki 24VDC 97x33mm DC Centrifugal Blower for medical equipment cooling A 97 × 33 mm frame and 24 VDC rating define 9BMB24P2K27, a DC blower for medical equipment cooling. Series options require suffix verification. The 97 × 33 mm format is the primary stated selection detail. Check cooling margin validation mounting size. Focus: cooling margin validation mounting size. |
24 | 97*33 | - | - | - | - | - | |
![]() 9G1224G1D04 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling The 120 × 120 × 38 mm Sanyo Denki 9G1224G1D04 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. For power-budget planning, start with the supplied static-pressure entry. Verify the exact bearing and signal options in the datasheet. Focus: cooling margin validation. |
24 | 120*120*38 | - | - | - | - | - | |
![]() 9A0624F4021 | Sanyo Denki 24VDC 1.2W DC Axial Fan for UPS, server and telecom equipment cooling Within servers, UPS systems, and telecom equipment, 9A0624F4021 provides a 60 × 60 × 25 mm, 24 VDC DC axial fan configuration. Series focus: high airflow and pressure. A listed noise figure of 24 dB is the key differentiating parameter. Check cooling margin validation static-pressure entry. Focus: cooling margin validation static-pressure entry. |
24 | 60*60*25 | 26 | 29.4 | 1.2 | 3200 | 24 | |
![]() 109P0505M702 | Sanyo Denki 5VDC DC Axial Fan for UPS, server and telecom equipment cooling 109P0505M702 addresses servers, UPS systems, and telecom equipment through a 5 VDC DC axial fan platform measuring 52 × 52 × 15 mm. High airflow is highlighted together with a high-static-pressure design. A listed noise figure of 22 dB is the key differentiating parameter. Check cooling margin validation volume-flow figure. |
5 | 52*52*15 | 12.1 | 21.5 | - | 3700 | 22 | |
![]() 9A0624S4D01 | Sanyo Denki 24VDC 1.92W DC Axial Fan for UPS, server and telecom equipment cooling The 60 × 60 × 25 mm Sanyo Denki 9A0624S4D01 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. The recorded selection parameters should guide controller selection. Confirm environmental protection for the ordered version. |
24 | 60*60*25 | 38.6 | 56.8 | 1.92 | 4600 | 33 | |
![]() 109R0812G4021 | Sanyo Denki 12VDC 4.44W DC Axial Fan for UPS, server and telecom equipment cooling The 80 × 80 × 25 mm Sanyo Denki 109R0812G4021 brings 12 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Review its static-pressure entry during power-budget planning. Confirm environmental protection for the ordered version. Focus: cooling margin validation rotational rating. |
12 | 80*80*25 | 88.8 | 80.4 | 4.44 | 4500 | 40 | |
![]() 109R0805F401 | Sanyo Denki 5VDC 1.25W DC Axial Fan for UPS, server and telecom equipment cooling The 109R0805F401 is a Sanyo Denki 5 VDC, 80 × 80 × 25 mm DC axial fan for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. Base equipment integration on the stated supply requirement. Obtain the applicable curve before final duty-point approval. Focus: cooling margin validation. |
5 | 80*80*25 | 54.6 | 28.4 | 1.25 | 2600 | 26 | |
![]() 109P0424F302 | Sanyo Denki 24VDC 1.32W DC Axial Fan for UPS, server and telecom equipment cooling The 109P0424F302 is a Sanyo Denki 24 VDC, 40 × 40 × 28 mm DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Treat the rotational rating as a primary input to cabinet ventilation planning. Check the full suffix before confirming connector details. Focus: cooling margin validation frame geometry. |
24 | 40*40*28 | - | - | 1.32 | 6700 | 30 | |
![]() 109R0624S4021 | Sanyo Denki 24VDC 1.92W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki 109R0624S4021 combines a 60 × 60 × 25 mm DC axial fan platform with a 24 VDC rating for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. A listed input of 1.92 W is the notable efficiency-related parameter. Selection focus: cooling margin validation cooling output. |
24 | 60*60*25 | 38.6 | 56.8 | 1.92 | 4600 | 33 | |
![]() 9G0924H202 | Sanyo Denki 24VDC 2.88W DC Axial Fan for UPS, server and telecom equipment cooling For thermal management in servers, UPS systems, and telecom equipment, the 9G0924H202 provides a 24 VDC DC axial fan configuration measuring 92 × 92 × 32 mm. Its 2850 rpm rating defines a lower-speed operating point. Use the documented acoustic value when planning thermal validation. Use the latest specification for frequency and tolerance limits. |
24 | 92*92*32 | 94.2 | 51.2 | 2.88 | 2850 | 32 | |
![]() 9G1224H401 | Sanyo Denki 24VDC 4.08W DC Axial Fan for UPS, server and telecom equipment cooling The 24 VDC Sanyo Denki 9G1224H401 is a DC axial fan sized 120 × 120 × 25 mm for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. Its 2850 rpm rating defines a lower-speed operating point. Check cooling margin validation dimensional envelope. Focus: cooling margin validation. |
24 | 120*120*25 | 149.6 | - | 4.08 | 2850 | 40 | |
![]() 9GA0924H402 | Sanyo Denki 24VDC 2.16W DC Axial Fan for UPS, server and telecom equipment cooling The 9GA0924H402 is a Sanyo Denki 24 VDC, 92 × 92 × 25 mm DC axial fan for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. For power-budget planning, start with the supplied frame geometry. Treat bearing and life data as suffix-specific. |
24 | 92*92*25 | 87.04 | - | 2.16 | 3300 | 31 | |
![]() 9GA0612H6001 | Sanyo Denki 12VDC 1.08W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki 9GA0612H6001 combines a 60 × 60 × 20 mm DC axial fan platform with a 12 VDC rating for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. A listed input of 1.08 W is the notable efficiency-related parameter. Focus: cooling margin validation. |
12 | 60*60*20 | 31.28 | 44.8 | 1.08 | 4100 | 29 |
The most reliable way to specify san Ace Dc Fan is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.
Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.
Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.
End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 576 products are available in this category today.
The daily work of our sales engineers is built around san Ace Dc Fan used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.
A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.
Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.
From one-piece emergency replacements to volume supply for equipment manufacturers, every Sanyo enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.
Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.
Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.
Every unit is covered by the manufacturer's warranty against defects in materials and workmanship, and we support you through the whole claim process so you deal with one supplier instead of chasing a factory overseas. If a failure appears in service, send us the serial number, operating conditions and photos, and we will arrange the replacement or credit path agreed in the quotation.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.