GF60252B3-10000-ADP addresses servers and data-center electronics through a 24 VDC DC axial fan platform measuring 60 × 60 × 25 mm. 104.6 Pa maximum pressure is the standout documented duty-point value. For cooling-margin review, start with the supplied product configuration. Check the full suffix before confirming connector details.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 60x60x25mm |
| Max.Air Flow(m³/h) | 45.7 |
| Max.Pressure(Pa) | 104.6 |
| Input Power(W) | 2.76 |
| Speed(rpm) | 6450 |
| Noise(db) | 38 |
The GF60252B3-10000-ADP from SUNON addresses cooling needs in server and data-center equipment. As a DC brushless axial fan, it creates a defined inlet-to-outlet route across the thermal load.
The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market. The enclosure should direct air across the heat source because bypass flow can reduce cooling even when the fan runs normally.
When qualifying GF60252B3-10000-ADP, give specific attention to service access. Use system-resistance review before design lock to align enclosure cooling, mechanical integration and lifecycle sourcing expectations. Retain access for inspection, cleaning and replacement after installation.
SUNON GF60252B3-10000-ADP serves server platforms. Airflow around processors, memory and power components helps address sustained computing loads. The fan gives OEM equipment a defined air route and supports stable server operation. It supports reliable equipment cooling.
SUNON GF60252B3-10000-ADP serves storage equipment. Airflow around drives, controllers and power assemblies helps address continuous data workloads. The fan gives OEM equipment a defined air route and supports reliable storage availability. It supports reliable equipment cooling.
SUNON GF60252B3-10000-ADP serves edge-computing systems. Airflow around compact processing and communication modules helps address high heat density. The fan gives OEM equipment a defined air route and supports consistent thermal control. It supports reliable equipment cooling.
SUNON GF60252B3-10000-ADP serves data-center equipment. Airflow around critical computing assemblies helps address round-the-clock heat generation. The fan gives OEM equipment a defined air route and supports infrastructure availability. It supports reliable equipment cooling.
Confirm any missing bearing, connector, control, IP rating, life, certification, and performance-curve details for the complete part number.
Speed-control capability is not stated for this complete part number. Confirm the signal and controller requirements before use.
Compare its listed 2.76 W input with the required airflow and run time. Total savings depend on the complete system duty point.
The listed speed is 6450 rpm. Confirm frequency, control method, and duty point for the installed system.
The worksheet lists up to 45.7 m³/h. Verify the operating point against system resistance.

Used in servers and data-center electronics, SUNON GF40282BX-10000-ADP is a 24 VDC DC axial fan in a 40 × 40 × 28 mm frame. 500.7 Pa maximum pressure is the standout documented duty-point value. The recorded power demand should guide cooling-margin review. Check the full suffix before confirming connector details.
Read More
SUNON configures GF40282B3-10000-ADP as a 40 × 40 × 28 mm DC axial fan for servers and data-center electronics, operating at 24 VDC. Its 500 rpm rating defines a lower-speed operating point. Treat the pressure capability as a primary input to cooling-margin review. Check the full suffix before confirming connector details.
Read More
For servers and data-center electronics, GF40282B2-10000-ADP combines 24 VDC operation with a 40 × 40 × 28 mm DC axial fan design. 276.5 Pa maximum pressure is the standout documented duty-point value. For cooling-margin review, start with the supplied speed benchmark. Check the full suffix before confirming connector details.
Read More
Positioned for servers and data-center electronics, SUNON GF40282B1-10000-ADP is a 24 VDC DC axial fan in a 40 × 40 × 28 mm frame. 343.7 Pa maximum pressure is the standout documented duty-point value. Base cabinet ventilation planning on the stated model record. Verify bearing and signal options in the exact datasheet.
Read More
Within servers and data-center electronics, SUNON GF40282B3-10000-SDP serves as a 40 × 40 × 28 mm DC axial fan operating at 24 VDC. 10500 W input is the defining electrical load in the supplied data. For cooling-margin review, start with the supplied frame geometry. Check the full suffix before confirming connector details.
Read More
GF40282B3-10000-QDP addresses servers and data-center electronics through a 24 VDC DC axial fan platform measuring 40 × 40 × 28 mm. 10500 W input is the defining electrical load in the supplied data. Use the documented cooling output when planning cooling-margin review. Check the full suffix before confirming connector details.
Read More