Home > Products > By type > Axial Fans > GF60252BX-10000-ADP | SUNON 24V 13.08W 60x60x25mm 93.1m3/h DC Axial Fan for Data Center Cooling

GF60252BX-10000-ADP SUNON Axial Fan

Brand :
SUNON
Model:
GF60252BX-10000-ADP | SUNON 24V 13.08W 60x60x25mm 93.1m3/h DC Axial Fan for Data Center Cooling
Type:
Axial Fans
Industry:
Data Center Cooling
Description:

Configured for servers and data-center electronics, SUNON GF60252BX-10000-ADP is a 24 VDC DC axial fan in a 60 × 60 × 25 mm frame. 12900 rpm is the model's most distinctive operating parameter. Treat the airflow profile as a primary input to fan selection. Use current model documentation to validate protection choices.

Datasheet:
GF60252BX-10000-ADP | SUNON 24V 13.08W 60x60x25mm 93.1m3/h DC Axial Fan for Data Center Cooling Datasheet (Pdf)

Product Features

Rated Voltage(V)24
Size(mm)60x60x25mm
Max.Air Flow(m³/h)93.1
Max.Pressure(Pa)358.7
Input Power(W)13.08
Speed(rpm)12900
Noise(db)55.4

Product Features

Reliable Fan Cooling

The SUNON GF60252BX-10000-ADP positions a DC brushless axial fan for server and data-center equipment. Its airflow path supports heat removal from enclosed components and toward the equipment exhaust.

The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market. The enclosure should direct air across the heat source because bypass flow can reduce cooling even when the fan runs normally.

For GF60252BX-10000-ADP integration, prioritize inlet clearance. Include maintenance planning in engineering approval, and confirm the full model interface before design lock. This supports reliable cooling and traceable purchasing. Keep the intake free from nearby walls or bundled wiring.

Application Industry

Frequently Asked Questions

What noise data are available for GF60252BX-10000-ADP?

The worksheet lists 55.4 dB. Installation distance, airflow resistance, and enclosure acoustics can change the measured result.

What airflow value is listed for GF60252BX-10000-ADP?

The worksheet lists up to 93.1 m³/h. Verify the operating point against system resistance.

Does GF60252BX-10000-ADP have a documented pressure rating?

Yes. The worksheet lists up to 358.7 Pa; compare it with the system curve.

How should GF60252BX-10000-ADP be matched to an enclosure?

Review its 60 × 60 × 25 mm size, 93.1 m³/h airflow, 358.7 Pa pressure, system resistance, and available mounting space.

What equipment can use GF60252BX-10000-ADP?

It is listed for servers and data-center electronics. Check dimensions, airflow, pressure, and the installation environment against the actual equipment.