Configured for servers and data-center electronics, SUNON GF60252BX-10000-ADP is a 24 VDC DC axial fan in a 60 × 60 × 25 mm frame. 12900 rpm is the model's most distinctive operating parameter. Treat the airflow profile as a primary input to fan selection. Use current model documentation to validate protection choices.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 60x60x25mm |
| Max.Air Flow(m³/h) | 93.1 |
| Max.Pressure(Pa) | 358.7 |
| Input Power(W) | 13.08 |
| Speed(rpm) | 12900 |
| Noise(db) | 55.4 |
The SUNON GF60252BX-10000-ADP positions a DC brushless axial fan for server and data-center equipment. Its airflow path supports heat removal from enclosed components and toward the equipment exhaust.
The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market. The enclosure should direct air across the heat source because bypass flow can reduce cooling even when the fan runs normally.
For GF60252BX-10000-ADP integration, prioritize inlet clearance. Include maintenance planning in engineering approval, and confirm the full model interface before design lock. This supports reliable cooling and traceable purchasing. Keep the intake free from nearby walls or bundled wiring.
SUNON GF60252BX-10000-ADP serves server platforms. Airflow around processors, memory and power components helps address sustained computing loads. The fan gives OEM equipment a defined air route and supports stable server operation. It supports reliable equipment cooling.
SUNON GF60252BX-10000-ADP serves storage equipment. Airflow around drives, controllers and power assemblies helps address continuous data workloads. The fan gives OEM equipment a defined air route and supports reliable storage availability. It supports reliable equipment cooling.
SUNON GF60252BX-10000-ADP serves edge-computing systems. Airflow around compact processing and communication modules helps address high heat density. The fan gives OEM equipment a defined air route and supports consistent thermal control. It supports reliable equipment cooling.
SUNON GF60252BX-10000-ADP serves data-center equipment. Airflow around critical computing assemblies helps address round-the-clock heat generation. The fan gives OEM equipment a defined air route and supports infrastructure availability. It supports reliable equipment cooling.
The worksheet lists 55.4 dB. Installation distance, airflow resistance, and enclosure acoustics can change the measured result.
The worksheet lists up to 93.1 m³/h. Verify the operating point against system resistance.
Yes. The worksheet lists up to 358.7 Pa; compare it with the system curve.
Review its 60 × 60 × 25 mm size, 93.1 m³/h airflow, 358.7 Pa pressure, system resistance, and available mounting space.
It is listed for servers and data-center electronics. Check dimensions, airflow, pressure, and the installation environment against the actual equipment.

Used in servers and data-center electronics, SUNON GF40282BX-10000-ADP is a 24 VDC DC axial fan in a 40 × 40 × 28 mm frame. 500.7 Pa maximum pressure is the standout documented duty-point value. The recorded power demand should guide cooling-margin review. Check the full suffix before confirming connector details.
Read More
SUNON configures GF40282B3-10000-ADP as a 40 × 40 × 28 mm DC axial fan for servers and data-center electronics, operating at 24 VDC. Its 500 rpm rating defines a lower-speed operating point. Treat the pressure capability as a primary input to cooling-margin review. Check the full suffix before confirming connector details.
Read More
For servers and data-center electronics, GF40282B2-10000-ADP combines 24 VDC operation with a 40 × 40 × 28 mm DC axial fan design. 276.5 Pa maximum pressure is the standout documented duty-point value. For cooling-margin review, start with the supplied speed benchmark. Check the full suffix before confirming connector details.
Read More
Positioned for servers and data-center electronics, SUNON GF40282B1-10000-ADP is a 24 VDC DC axial fan in a 40 × 40 × 28 mm frame. 343.7 Pa maximum pressure is the standout documented duty-point value. Base cabinet ventilation planning on the stated model record. Verify bearing and signal options in the exact datasheet.
Read More
Within servers and data-center electronics, SUNON GF40282B3-10000-SDP serves as a 40 × 40 × 28 mm DC axial fan operating at 24 VDC. 10500 W input is the defining electrical load in the supplied data. For cooling-margin review, start with the supplied frame geometry. Check the full suffix before confirming connector details.
Read More
GF40282B3-10000-QDP addresses servers and data-center electronics through a 24 VDC DC axial fan platform measuring 40 × 40 × 28 mm. 10500 W input is the defining electrical load in the supplied data. Use the documented cooling output when planning cooling-margin review. Check the full suffix before confirming connector details.
Read More