| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() EF50151B1-C02C-A99 | SUNON 12V 1.28W 50x50x15mm DC Centrifugal Blower for Industrial Cooling EF50151B1-C02C-A99 addresses telecom cabinets, base stations, and network equipment through a 12 VDC DC blower platform measuring 50 × 50 × 15 mm. Its 7.6 m³/h airflow rating suits the stated equipment-cooling role. Base airflow-path design on the stated product configuration. Obtain the applicable curve before final duty-point approval. |
12 | 50x50x15mm | 7.6 | 166.9 | 1.28 | 5200 | 41 | |
![]() EF50151B2-C03C-A99 | SUNON 12V 0.65W 50x50x15mm DC Centrifugal Blower for Industrial Cooling SUNON EF50151B2-C03C-A99 combines a 50 × 50 × 15 mm DC blower platform with a 12 VDC rating for telecom cabinets, base stations, and network equipment. Its 5.9 m³/h airflow rating suits the stated equipment-cooling role. During airflow-path design, compare the model's system interface. Obtain the applicable curve before final duty-point approval. |
12 | 50x50x15mm | 5.9 | 99.6 | 0.65 | 4200 | 34 | |
![]() HA40101V4-1000U-999 | SUNON 12V 0.38W 40x40x10mm 9.2m3/h DC Axial Fan for Industrial Cooling Designed for telecom cabinets, base stations, and network equipment, SUNON HA40101V4-1000U-999 is a 12 VDC DC axial fan in a 40 × 40 × 10 mm frame. A listed noise value of 15.7 dB is the model's key differentiator. The recorded cooling specification should guide airflow-path design. Obtain the applicable curve before final duty-point approval. |
12 | 40x40x10mm | 9.2 | 22.4 | 0.38 | 5000 | 15.7 | |
![]() PF75302B1-1B00U-G99 | SUNON 24V 2.76W 75x75x30mm DC Centrifugal Blower for Industrial Cooling The 24 VDC SUNON PF75302B1-1B00U-G99 is a DC blower sized 75 × 75 × 30 mm for servers and data-center electronics. Its 26.35 m³/h airflow rating suits the stated equipment-cooling role. Use the documented installation footprint when planning airflow-path design. Obtain the applicable curve before final duty-point approval. |
24 | 75x75x30mm | 26.35 | - | 2.76 | 3400 | 42 | |
![]() EF92252B1-000U-G99 | SUNON 24V 1.52W 92x92x25mm 87.5m3/h DC Axial Fan for Industrial Cooling The EF92252B1-000U-G99 is SUNON's 24 VDC, 92 × 92 × 25 mm DC axial fan option for telecom cabinets, base stations, and network equipment. Its 3000 rpm rating defines a lower-speed operating point. Review its selection parameters during airflow-path design. Obtain the applicable curve before final duty-point approval. |
24 | 92x92x25mm | 87.5 | 42.3 | 1.52 | 3000 | 34 | |
![]() EF92252BX-1000U-G99 | SUNON 24V 2.16W 92x92x25mm 93.4m3/h DC Axial Fan for Industrial Cooling For telecom cabinets, base stations, and network equipment, EF92252BX-1000U-G99 combines 24 VDC operation with a 92 × 92 × 25 mm DC axial fan design. Up to 93.4 m³/h is its most prominent listed performance figure. Treat the rated dataset as a primary input to airflow-path design. Obtain the applicable curve before final duty-point approval. |
24 | 92x92x25mm | 93.4 | 52.3 | 2.16 | 3400 | 36.9 | |
![]() PF92252V1-1000U-G99 | SUNON 24V 5.04W 92x92x25mm 4500rpm DC Axial Fan for Industrial Cooling SUNON PF92252V1-1000U-G99 combines a 92 × 92 × 25 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. 5.04 W input is the defining electrical load in the supplied data. Base airflow-path design on the stated motor input. Obtain the applicable curve before final duty-point approval. |
24 | 92x92x25mm | - | 87.2 | 5.04 | 4500 | - | |
![]() PF80252B1-1000U-G99 | SUNON 24V 3.72W 80x80x25mm 4800rpm DC Axial Fan for Industrial Cooling Used in servers and data-center electronics, SUNON PF80252B1-1000U-G99 is a 24 VDC DC axial fan in a 80 × 80 × 25 mm frame. 102.1 Pa maximum pressure is the standout documented duty-point value. During airflow-path design, compare the model's ventilation capacity. Obtain the applicable curve before final duty-point approval. |
24 | 80x80x25mm | - | 102.1 | 3.72 | 4800 | - | |
![]() ME80152V1-000U-G99 | SUNON 24V 2.21W 80x80x15mm 62.9m3/h DC Axial Fan for Industrial Cooling Built for industrial electronics and equipment cooling, SUNON ME80152V1-000U-G99 uses a 80 × 80 × 15 mm DC blower arrangement at 24 VDC. Its 3000 rpm rating defines a lower-speed operating point. For airflow-path design, start with the supplied suffix definition. Obtain the applicable curve before final duty-point approval. |
24 | 80x80x15mm | 62.9 | 34.9 | 2.21 | 3000 | 34.7 | |
![]() ME70151V3-000U-A99 | SUNON 12V 0.57W 70x70x15mm 32.3m3/h DC Axial Fan for Industrial Cooling The ME70151V3-000U-A99 is SUNON's 12 VDC, 70 × 70 × 15 mm DC blower option for industrial electronics and equipment cooling. Its 2300 rpm rating defines a lower-speed operating point. Use the documented catalog specification when planning airflow-path design. Obtain the applicable curve before final duty-point approval. |
12 | 70x70x15mm | 32.3 | 17.4 | 0.57 | 2300 | 21.5 | |
![]() PMD2407PTB3-A.F | SUNON 24V 2.9W 70x70x25mm 68m3/h 4200rpm DC Axial Fan for Industrial Cooling For compact cooling within industrial electronics and equipment cooling, the PMD2407PTB3-A.F provides a 24 VDC DC blower configuration measuring 70 × 70 × 25 mm. Its 4200 rpm rating defines a lower-speed operating point. Review its thermal-duty record during airflow-path design. Obtain the applicable curve before final duty-point approval. |
24 | 70x70x25mm | 68 | 62.3 | 2.9 | 4200 | 39 | |
![]() EE50101S1-1000U-C99 | SUNON 12V 1.08W 50x50x10mm 22.1m3/h DC Axial Fan for Industrial Cooling Within telecom cabinets, base stations, and network equipment, SUNON EE50101S1-1000U-C99 serves as a 50 × 50 × 10 mm DC blower operating at 12 VDC. Its 22.1 m³/h airflow rating suits the stated equipment-cooling role. During airflow-path design, compare the model's supply requirement. Obtain the applicable curve before final duty-point approval. |
12 | 50x50x10mm | 22.1 | 34.9 | 1.08 | 5700 | 30.7 | |
![]() EF40201BX-1000U-G99 | SUNON 12V 0.78W 40x40x20mm 8200rpm DC Axial Fan for Industrial Cooling EF40201BX-1000U-G99 serves telecom cabinets, base stations, and network equipment as a 40 × 40 × 20 mm DC axial fan rated at 12 VDC. 8200 rpm is the model's most distinctive operating parameter. The recorded static-pressure entry should guide airflow-path design. Obtain the applicable curve before final duty-point approval. |
12 | 40x40x20mm | - | 79.7 | 0.78 | 8200 | - | |
![]() EEC0251B2-000U-G99 | SUNON 12V 3.4W 120x120x25mm 2700rpm DC Axial Fan for Industrial Cooling The EEC0251B2-000U-G99 is SUNON's 12 VDC, 120 × 120 × 25 mm DC axial fan option for telecom cabinets, base stations, and network equipment. Its 2700 rpm rating defines a lower-speed operating point. For airflow-path design, start with the supplied volume-flow figure. Obtain the applicable curve before final duty-point approval. |
12 | 120x120x25mm | - | 54.8 | 3.4 | 2700 | - | |
![]() GM1202PFV2-8 F.GN | SUNON 12V 3W 25x25x10mm 5.1m3/h 10000rpm DC Axial Fan for Industrial Cooling GM1202PFV2-8 F.GN addresses industrial electronics and equipment cooling through a 12 VDC DC blower platform measuring 25 × 25 × 10 mm. Its 5.1 m³/h airflow rating suits the stated equipment-cooling role. During airflow-path design, compare the model's cooling output. Obtain the applicable curve before final duty-point approval. |
12 | 25*25*10 | 5.1 | - | 3 | 10000 | 16 | |
![]() ME80251V3-000U-F99 | SUNON 12V 1.1W 80x80x25mm DC Axial Fan for Industrial Cooling The ME80251V3-000U-F99 is SUNON's 12 VDC, 80 × 80 × 25 mm DC blower option for industrial electronics and equipment cooling. A listed input of 1.1 W is the model's notable electrical characteristic. The recorded operating point should guide airflow-path design. Obtain the applicable curve before final duty-point approval. |
12 | 80*80*25 | - | - | 1.1 | - | - | |
![]() PF80251B3-1000U-S99 | SUNON 12V 2.34W 80x80x25mm 90.1m3/h DC Axial Fan for Industrial Cooling Built around servers and data-center electronics, SUNON PF80251B3-1000U-S99 is a 12 VDC DC axial fan in a 80 × 80 × 25 mm frame. Up to 90.1 m³/h is its most prominent listed performance figure. Review its acoustic value during airflow-path design. Obtain the applicable curve before final duty-point approval. |
12 | 80*80*25 | 90.1 | - | 2.34 | 4200 | 42.5 | |
![]() PF40281B1-Q135-SA9 | SUNON 12V 6.12W 40x40x28mm 42.3m3/h DC Axial Fan for Industrial Cooling Within servers and data-center electronics, SUNON PF40281B1-Q135-SA9 serves as a 40 × 40 × 28 mm DC axial fan operating at 12 VDC. 17600 rpm is the model's most distinctive operating parameter. Treat the electrical load as a primary input to airflow-path design. Obtain the applicable curve before final duty-point approval. |
12 | 40x40x28mm | 42.3 | 510.6 | 6.12 | 17600 | 56 | |
![]() EF60202B3-000U-A99 | SUNON 24V 0.56W 60x60x20mm 24m3/h DC Axial Fan for Industrial Cooling For telecom cabinets, base stations, and network equipment, EF60202B3-000U-A99 combines 24 VDC operation with a 60 × 60 × 20 mm DC axial fan design. A listed input of 0.56 W is the model's notable electrical characteristic. Base airflow-path design on the stated speed benchmark. Obtain the applicable curve before final duty-point approval. |
24 | 60x60x20mm | 24 | 22.4 | 0.56 | 3000 | 24.5 | |
![]() EEC0252B3-000U-G99 | SUNON 24V 2W 120x120x25mm 75m3/h DC Axial Fan for Industrial Cooling Specified at 24 VDC, EEC0252B3-000U-G99 is a SUNON DC axial fan for telecom cabinets, base stations, and network equipment in 120 × 120 × 25 mm dimensions. Its 2200 rpm rating defines a lower-speed operating point. The recorded application data should guide acoustic assessment. Match the exact part number before approving a substitute. |
24 | 120*120*25 | 75 | - | 2 | 2200 | 34 |
Choosing the right industrial Cooling starts with the operating point rather than the model name. Define the airflow you actually need in CFM or m³/h and the static pressure the fan must overcome, then look for units whose performance curves pass through that point with a safety margin instead of sitting at the edge of the curve.
Pay attention to the electrical details early. DC fans typically run on 12/24/48 V and integrate easily with control boards, while AC fans suit 115/230 V fixed-speed installations. If the airflow must change with load, choose EC technology with PWM or analog control and, where monitoring matters, a tachometer output so the controller can detect fan failure.
Environment and compliance come next. Match the IP rating to dust and moisture exposure, prefer ball bearings wherever the fan runs hot, vertically or around the clock, and confirm certifications — UL, CE, RoHS — against your destination market. Setting the acoustic limit in dBA early prevents late-stage redesign when the first unit proves too loud.
Finally, compare candidates on total delivery risk, not only on price: confirm stock for the quantity you need, check the lead time for the next batch, and ask for datasheets and dimension drawings before committing. Our team cross-checks curves, dimensions and electrical data for you before quotation There are currently 912 items in this category ready to compare.
Industrial Cooling appear in almost every sector where heat or stale air must be moved reliably. Typical environments include server rooms and data centers, refrigeration condensers and cold-store evaporators, HVAC air handling units, telecom cabinets, medical and laboratory equipment, welding and CNC machine enclosures, and renewable-energy power cabinets. In each of these settings the fan is a critical component: its failure stops production, damages stored goods or forces expensive emergency downtime.
One recurring scenario comes from control cabinet retrofits: the original fan is obsolete, the mounting hole pattern cannot change, and downtime is measured in hours. We match the old unit against current series by frame size, airflow and noise, propose the closest drop-in alternative, and ship with a datasheet that lets the electrician connect it without redesign.
For cold storage operators the pain is simple: a failed evaporator or condenser fan must be replaced now, not after a six-week import cycle. Matching blade diameter, speed and protection class against stocked equivalents lets us restore cooling capacity within days, which is why replacement supply has become a core part of this category for us.
Whether you are building new equipment or maintaining an installed base, the workflow is the same: send us the operating point and constraints, and we return a validated selection with datasheets, curves and a clear lead time.
Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 912 products in this category are listed online.
Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.
Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.