| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() MF50101V1-1000U-F99 | SUNON 12V 0.84W 50x50x10mm 5800rpm DC Axial Fan for New Energy MF50101V1-1000U-F99 serves inverters, energy-storage systems, and charging equipment as a 50 × 50 × 10 mm DC axial fan rated at 12 VDC. A listed input of 0.84 W is the model's notable electrical characteristic. Treat the electrical load as a primary input to maintenance preparation. Confirm temperature and service-life limits from current data. |
12 | 50x50x10mm | - | 37.4 | 0.84 | 5800 | - | |
![]() MF60252VX-10000-A99 | SUNON 24V 1.92W 60x60x25mm 45.9m3/h 5200rpm DC Axial Fan for New Energy The MF60252VX-10000-A99 is SUNON's 24 VDC, 60 × 60 × 25 mm DC axial fan option for inverters, energy-storage systems, and charging equipment. A listed noise value of 31.2 dB is the model's key differentiator. For service-life planning, start with the supplied selection parameters. Check the ordering suffix before assigning control functions. |
24 | 60x60x25mm | 45.9 | 77.2 | 1.92 | 5200 | 31.2 | |
![]() MF60151V1-10000-G99 | SUNON 12V 1.53W 60x60x15mm 44.9m3/h 4700rpm DC Axial Fan for New Energy SUNON MF60151V1-10000-G99 combines a 60 × 60 × 15 mm DC blower platform with a 12 VDC rating for inverters, energy-storage systems, and charging equipment. A listed input of 1.53 W is the model's notable electrical characteristic. Review its motor input during service-life planning. Check the ordering suffix before assigning control functions. |
12 | 60x60x15mm | 44.9 | 44.8 | 1.53 | 4700 | 34.2 | |
![]() EF40201BX-1Q050-S99 | SUNON 12V 0.78W 40x40x20mm 18.3m3/h DC Axial Fan for 5G Network Equipment SUNON EF40201BX-1Q050-S99 combines a 40 × 40 × 20 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 8200 rpm is the model's most distinctive operating parameter. Review its static-pressure entry during procurement comparison. Use the latest specification for frequency and tolerance limits. |
12 | 40x40x20mm | 18.3 | 79.7 | 0.78 | 8200 | 28.5 | |
![]() MF50101V1-1000U-G99 | SUNON 12V 0.84W 50x50x10mm 5800rpm DC Axial Fan for New Energy SUNON MF50101V1-1000U-G99 combines a 50 × 50 × 10 mm DC axial fan platform with a 12 VDC rating for inverters, energy-storage systems, and charging equipment. A listed input of 0.84 W is the model's notable electrical characteristic. The recorded suffix definition should guide wiring review. Confirm environmental protection for the ordered version. |
12 | 50x50x10mm | - | 37.4 | 0.84 | 5800 | - | |
![]() MF60151VX-1000U-G99 | SUNON 12V 1.98W 60x60x15mm 5400rpm DC Axial Fan for New Energy SUNON MF60151VX-1000U-G99 combines a 60 × 60 × 15 mm DC blower platform with a 12 VDC rating for inverters, energy-storage systems, and charging equipment. 5400 rpm is the model's most distinctive operating parameter. Review its system interface during controller selection. Treat bearing and life data as suffix-specific. |
12 | 60x60x15mm | - | 54.8 | 1.98 | 5400 | - | |
![]() MF50201V1-1Q030-S99 | SUNON 12V 1.49W 50x50x20mm DC Centrifugal Blower for Edge Computing Equipment Configured for servers and data-center electronics, SUNON MF50201V1-1Q030-S99 is a 12 VDC DC blower in a 50 × 50 × 20 mm frame. Its 9.9 m³/h airflow rating suits the stated equipment-cooling role. Treat the cooling specification as a primary input to controller selection. Treat bearing and life data as suffix-specific. |
12 | 50x50x20mm | 9.9 | 164.4 | 1.49 | 5300 | 34.8 | |
![]() PF80801BX-000U-S9H | SUNON 12V 81.6W 80x80x80mm 257.55m3/h DC Axial Fan for Data Storage Systems Equipment designers working with servers and data-center electronics can evaluate SUNON PF80801BX-000U-S9H, a DC axial fan rated at 12 VDC and sized 80 × 80 × 80 mm. 1355 Pa maximum pressure is the standout documented duty-point value. Review its cooling output during controller selection. Treat bearing and life data as suffix-specific. |
12 | 80x80x80mm | 257.55 | 1355 | 81.6 | 15600 | 80.4 | |
![]() MF30101V1-1000U-S99 | SUNON 12V 0.66W 30x30x10mm 9.3m3/h 11500rpm DC Axial Fan for New Energy SUNON configures MF30101V1-1000U-S99 as a 30 × 30 × 10 mm DC axial fan for inverters, energy-storage systems, and charging equipment, operating at 12 VDC. 11500 rpm is the model's most distinctive operating parameter. Base controller selection on the stated pressure capability. Treat bearing and life data as suffix-specific. |
12 | 30x30x10mm | 9.3 | 62.3 | 0.66 | 11500 | 23 | |
![]() EF60251BX-Q09C-S99 | SUNON 12V 2.4W 60x60x25mm DC Axial Fan for Potential Applications In Telecommunications, Data Centers Built around servers and data-center electronics, SUNON EF60251BX-Q09C-S99 is a 12 VDC DC blower in a 60 × 60 × 25 mm frame. 2.4 W input is the defining electrical load in the supplied data. Treat the catalog specification as a primary input to mounting verification. Validate mounting and wiring from the model drawing. |
12 | 60*60*25 | - | - | 2.4 | - | - | |
![]() MF30100V2-1000U-A99 | SUNON 5V 0.4W 30x30x10mm 8m3/h DC Axial Fan for Edge Computing Equipment Within servers and data-center electronics, SUNON MF30100V2-1000U-A99 serves as a 30 × 30 × 10 mm DC axial fan operating at 5 VDC. A listed input of 0.4 W is the model's notable electrical characteristic. Base mounting verification on the stated thermal-duty record. Validate mounting and wiring from the model drawing. |
5 | 30x30x10 | 8 | 42.3 | 0.4 | 9500 | 21 | |
![]() EF60151BX-Q010-S99 | SUNON 12V 1.44W 60x60x15mm DC Axial Fan for 5G Network Equipment The 12 VDC SUNON EF60151BX-Q010-S99 is a DC blower sized 60 × 60 × 15 mm for servers and data-center electronics. A listed input of 1.44 W is the model's notable electrical characteristic. For mounting verification, start with the supplied supply requirement. Validate mounting and wiring from the model drawing. |
12 | 60*60*15 | - | - | 1.44 | - | - | |
![]() MF40101V2-1Q030-S99 | SUNON 12V 0.48W 40x40x10mm 11.9m3/h DC Axial Fan for Potential Applications In Telecommunications Within servers and data-center electronics, SUNON MF40101V2-1Q030-S99 serves as a 40 × 40 × 10 mm DC axial fan operating at 12 VDC. A listed input of 0.48 W is the model's notable electrical characteristic. Review its pressure capability during mounting verification. Validate mounting and wiring from the model drawing. |
12 | 40x40x10mm | 11.9 | 29.9 | 0.48 | 5800 | 20.6 | |
![]() VF80381BX-Q394-S9H | SUNON 12V 57.96W 80x80x38mm DC Axial Fan for Potential Applications In Telecommunications SUNON VF80381BX-Q394-S9H combines a 80 × 80 × 38 mm DC blower platform with a 12 VDC rating for servers and data-center electronics. 57.96 W input is the defining electrical load in the supplied data. Use the documented dimensional envelope when planning airflow-path design. Obtain the applicable curve before final duty-point approval. |
12 | 80*80*38 | - | - | 57.96 | - | - | |
![]() MF50151VX-1B00U-G99 | SUNON 12V 1.86W 50x50x15mm 6200rpm DC Axial Fan for New Energy The MF50151VX-1B00U-G99 is SUNON's 12 VDC, 50 × 50 × 15 mm DC blower option for inverters, energy-storage systems, and charging equipment. 241.6 Pa maximum pressure is the standout documented duty-point value. Base acoustic assessment on the stated cooling specification. Match the exact part number before approving a substitute. |
12 | 50x50x15mm | - | 241.6 | 1.86 | 6200 | - | |
![]() MF30101V1-1000U-F99 | SUNON 12V 0.83W 30x30x10mm 9.35m3/h 11500rpm DC Axial Fan for New Energy Within inverters, energy-storage systems, and charging equipment, SUNON MF30101V1-1000U-F99 serves as a 30 × 30 × 10 mm DC axial fan operating at 12 VDC. 11500 rpm is the model's most distinctive operating parameter. The recorded electrical load should guide power-budget planning. Confirm control inputs against the complete ordering code. |
12 | 30*30*10 | 9.35 | - | 0.83 | 11500 | 23 | |
![]() MF60151VX-1000U-A99 | SUNON 12V 2.28W 60x60x15mm 30.4m3/h 5400rpm DC Axial Fan for New Energy The 60 × 60 × 15 mm MF60151VX-1000U-A99 brings 12 VDC DC blower cooling to inverters, energy-storage systems, and charging equipment. Its 30.4 m³/h airflow rating suits the stated equipment-cooling role. Treat the technical profile as a primary input to system-resistance review. Use current model documentation to validate protection choices. |
12 | 60*60*15 | 30.4 | - | 2.28 | 5400 | 36.2 | |
![]() MF60151V1-1000U-A99 | SUNON 12V 1.58W 60x60x15mm 26.4m3/h 4700rpm DC Axial Fan for New Energy MF60151V1-1000U-A99 serves inverters, energy-storage systems, and charging equipment as a 60 × 60 × 15 mm DC blower rated at 12 VDC. Its 26.4 m³/h airflow rating suits the stated equipment-cooling role. Treat the selection parameters as a primary input to system-resistance review. Use current model documentation to validate protection choices. |
12 | 60*60*15 | 26.4 | - | 1.58 | 4700 | 34.2 | |
![]() MF50152VX-1000U-A99 | SUNON 24V 1.4W 50x50x15mm 18.6m3/h 7200rpm DC Axial Fan for New Energy Applied in inverters, energy-storage systems, and charging equipment, SUNON MF50152VX-1000U-A99 is a 24 VDC DC axial fan in a 50 × 50 × 15 mm frame. 7200 rpm is the model's most distinctive operating parameter. Use the documented acoustic value when planning replacement evaluation. Check the full suffix before confirming connector details. |
24 | 50*50*15 | 18.6 | - | 1.4 | 7200 | 38.1 | |
![]() MF60252VX-1000U-A99 | SUNON 24V 2.04W 60x60x25mm 27m3/h 5200rpm DC Axial Fan for New Energy SUNON MF60252VX-1000U-A99 is a 24 VDC DC axial fan for inverters, energy-storage systems, and charging equipment. Its 27 m³/h airflow rating suits the stated equipment-cooling role. Treat the speed benchmark as a primary input to replacement evaluation. Check the full suffix before confirming connector details. |
24 | 60*60*25 | 27 | - | 2.04 | 5200 | 31.2 |
The most reliable way to specify new Energy is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.
Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.
Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.
End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 1,181 products are available in this category today.
The daily work of our sales engineers is built around new Energy used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.
A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.
Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.
From one-piece emergency replacements to volume supply for equipment manufacturers, every enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.
Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.
Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.
Every unit is covered by the manufacturer's warranty against defects in materials and workmanship, and we support you through the whole claim process so you deal with one supplier instead of chasing a factory overseas. If a failure appears in service, send us the serial number, operating conditions and photos, and we will arrange the replacement or credit path agreed in the quotation.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.