| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() MF50152V1-1000U-A99 | SUNON 24V 1.08W 50x50x15mm 17m3/h DC Axial Fan for Telecommunications The MF50152V1-1000U-A99 is SUNON's 24 VDC, 50 × 50 × 15 mm DC axial fan option for telecom cabinets and network equipment. Its 17 m³/h airflow rating suits the stated equipment-cooling role. Use the documented airflow profile when planning power-budget planning. Confirm control inputs against the complete ordering code. |
24 | 50*50*15 | 17 | - | 1.08 | 6100 | 33 | |
![]() MF30101V2-1000U-A99 | SUNON 12V 0.7W 30x30x10mm 7.82m3/h DC Axial Fan for Telecommunications A 30 × 30 × 10 mm frame and 12 VDC rating define MF30101V2-1000U-A99, a DC axial fan for telecom cabinets and network equipment. A listed noise value of 20 dB is the model's key differentiator. The recorded system interface should guide system-resistance review. Use current model documentation to validate protection choices. |
12 | 30*30*10 | 7.82 | - | 0.7 | 8600 | 20 | |
![]() MF50101V2-1000U-A99 | SUNON 12V 0.6W 50x50x10mm 18.5m3/h DC Axial Fan for Telecommunications Within telecom cabinets and network equipment, MF50101V2-1000U-A99 provides a 50 × 50 × 10 mm, 12 VDC DC axial fan configuration. A listed input of 0.6 W is the model's notable electrical characteristic. Use the documented duty-point values when planning system-resistance review. Use current model documentation to validate protection choices. |
12 | 50x50x10 | 18.5 | 27.4 | 0.6 | 4800 | 25.6 | |
![]() MF40060V2-1000U-A99 | SUNON 5V 0.45W 40x40x6mm 5.5m3/h DC Axial Fan for Telecommunications SUNON MF40060V2-1000U-A99 combines a 40 × 40 × 6 mm DC axial fan platform with a 5 VDC rating for telecom cabinets and network equipment. Its 5.5 m³/h airflow rating suits the stated equipment-cooling role. Review its installation footprint during system-resistance review. Use current model documentation to validate protection choices. |
5 | 40*40*6 | 5.5 | - | 0.45 | 6000 | 25.3 | |
![]() MF50151V2-B00U-A99 | SUNON 12V 0.68W 50x50x15mm 5.9m3/h DC Axial Fan for Telecommunications Within telecom cabinets and network equipment, SUNON MF50151V2-B00U-A99 serves as a 50 × 50 × 15 mm DC blower operating at 12 VDC. Its 5.9 m³/h airflow rating suits the stated equipment-cooling role. Base system-resistance review on the stated rated dataset. Use current model documentation to validate protection choices. |
12 | 50x50x15mm | 5.9 | 99.6 | 0.68 | 4000 | 33.1 | |
![]() MF40102VX-1Q03U-A99 | SUNON 24V 1.92W 40x40x10mm 11m3/h DC Axial Fan for Telecommunications SUNON MF40102VX-1Q03U-A99 is a 24 VDC DC blower in a 40 × 40 × 10 mm format for telecom cabinets and network equipment. 10000 rpm is the model's most distinctive operating parameter. During system-resistance review, compare the model's motor input. Use current model documentation to validate protection choices. |
24 | 40*40*10 | 11 | - | 1.92 | 10000 | 36.8 | |
![]() MF80251V3-1000U-A99 | SUNON 12V 0.78W 80x80x25mm 33m3/h DC Axial Fan for Telecommunications The MF80251V3-1000U-A99 is SUNON's 12 VDC, 80 × 80 × 25 mm DC axial fan option for telecom cabinets and network equipment. Its 2600 rpm rating defines a lower-speed operating point. The recorded ventilation capacity should guide system-resistance review. Use current model documentation to validate protection choices. |
12 | 80*80*25 | 33 | - | 0.78 | 2600 | 28 | |
![]() MF40201V3-1000U-A99 | SUNON 12V 0.5W 40x40x20mm 6.3m3/h DC Axial Fan for Telecommunications The 40 × 40 × 20 mm MF40201V3-1000U-A99 brings 12 VDC DC axial fan cooling to telecom cabinets and network equipment. A listed noise value of 16.5 dB is the model's key differentiator. For system-resistance review, start with the supplied equipment fit. Use current model documentation to validate protection choices. |
12 | 40*40*20 | 6.3 | - | 0.5 | 5000 | 16.5 | |
![]() MF60201V1-1000U-A99 | SUNON 12V 1.56W 60x60x20mm 23m3/h DC Axial Fan for Telecommunications Applied in telecom cabinets and network equipment, SUNON MF60201V1-1000U-A99 is a 12 VDC DC axial fan in a 60 × 60 × 20 mm frame. Its 23 m³/h airflow rating suits the stated equipment-cooling role. Review its catalog specification during system-resistance review. Use current model documentation to validate protection choices. |
12 | 60*60*20 | 23 | - | 1.56 | 5000 | 33.5 | |
![]() MF17080V2-1000U-A99 | SUNON 5V 0.63W 17x17x8mm 0.7m3/h DC Axial Fan for Telecommunications SUNON configures MF17080V2-1000U-A99 as a 17 × 17 × 8 mm DC axial fan for telecom cabinets and network equipment, operating at 5 VDC. Its 0.7 m³/h airflow rating suits the stated equipment-cooling role. Base system-resistance review on the stated performance curve. Use current model documentation to validate protection choices. |
5 | 17*17*8 | 0.7 | - | 0.63 | 16500 | 14.2 | |
![]() MF50151V3-1000U-A99 | SUNON 12V 0.48W 50x50x15mm 10.2m3/h DC Axial Fan for Telecommunications SUNON MF50151V3-1000U-A99 combines a 50 × 50 × 15 mm DC blower platform with a 12 VDC rating for telecom cabinets and network equipment. A listed noise value of 20.1 dB is the model's key differentiator. For system-resistance review, start with the supplied static-pressure entry. Use current model documentation to validate protection choices. |
12 | 50*50*15 | 10.2 | - | 0.48 | 3800 | 20.1 | |
![]() MF40101VX-1000U-G99 | SUNON 12V 1.17W 40x40x10mm 16.83m3/h DC Axial Fan for Telecommunications Built for telecom cabinets and network equipment, SUNON MF40101VX-1000U-G99 uses a 40 × 40 × 10 mm DC axial fan arrangement at 12 VDC. 8500 rpm is the model's most distinctive operating parameter. During system-resistance review, compare the model's frame geometry. Use current model documentation to validate protection choices. |
12 | 40*40*10 | 16.83 | - | 1.17 | 8500 | 31.4 | |
![]() MF60202V1-1000U-A99 | SUNON 24V 1.44W 60x60x20mm 23m3/h DC Axial Fan for Telecommunications Built around telecom cabinets and network equipment, SUNON MF60202V1-1000U-A99 is a 24 VDC DC axial fan in a 60 × 60 × 20 mm frame. Its 23 m³/h airflow rating suits the stated equipment-cooling role. For system-resistance review, start with the supplied operating point. Use current model documentation to validate protection choices. |
24 | 60*60*20 | 23 | - | 1.44 | 5000 | 33.5 | |
![]() MF92252V1-1000U-A99 | SUNON 24V 1.92W 92x92x25mm 51.5m3/h DC Axial Fan for Telecommunications SUNON MF92252V1-1000U-A99 combines a 92 × 92 × 25 mm DC axial fan platform with a 24 VDC rating for telecom cabinets and network equipment. Its 3000 rpm rating defines a lower-speed operating point. During system-resistance review, compare the model's speed benchmark. Use current model documentation to validate protection choices. |
24 | 92*92*25 | 51.5 | - | 1.92 | 3000 | 34 | |
![]() MF80251V1-1000U-A99 | SUNON 12V 1.44W 80x80x25mm 41m3/h DC Axial Fan for Telecommunications Configured for telecom cabinets and network equipment, SUNON MF80251V1-1000U-A99 is a 12 VDC DC axial fan in a 80 × 80 × 25 mm frame. Its 3200 rpm rating defines a lower-speed operating point. The recorded airflow profile should guide system-resistance review. Use current model documentation to validate protection choices. |
12 | 80*80*25 | 41 | - | 1.44 | 3200 | 33 | |
![]() MF40202VX-1000U-A99 | SUNON 24V 1.11W 40x40x20mm 10.8m3/h DC Axial Fan for Telecommunications Within telecom cabinets and network equipment, SUNON MF40202VX-1000U-A99 serves as a 40 × 40 × 20 mm DC axial fan operating at 24 VDC. Its 10.8 m³/h airflow rating suits the stated equipment-cooling role. For replacement evaluation, start with the supplied application data. Check the full suffix before confirming connector details. |
24 | 40*40*20 | 10.8 | - | 1.11 | 8000 | 27.5 | |
![]() MF60251VX-1000U-A99 | SUNON 12V 1.56W 60x60x25mm 27m3/h DC Axial Fan for Telecommunications MF60251VX-1000U-A99 addresses telecom cabinets and network equipment through a 12 VDC DC axial fan platform measuring 60 × 60 × 25 mm. Its 27 m³/h airflow rating suits the stated equipment-cooling role. Treat the product configuration as a primary input to replacement evaluation. Check the full suffix before confirming connector details. |
12 | 60*60*25 | 27 | - | 1.56 | 5200 | 31.2 | |
![]() MF40101V2-1000U-A99 | SUNON 12V 0.59W 40x40x10mm 7m3/h DC Axial Fan for Telecommunications Engineered for telecom cabinets and network equipment, SUNON MF40101V2-1000U-A99 is a 12 VDC DC axial fan in a 40 × 40 × 10 mm frame. Its 7 m³/h airflow rating suits the stated equipment-cooling role. During replacement evaluation, compare the model's cooling specification. Check the full suffix before confirming connector details. |
12 | 40*40*10 | 7 | - | 0.59 | 5800 | 20.6 | |
![]() MF50151V2-1C01A-S99 | SUNON 12V 0.51W 50x50x15mm 22.1m3/h DC Axial Fan for Telecommunications The 12 VDC SUNON MF50151V2-1C01A-S99 is a DC blower sized 50 × 50 × 15 mm for telecom cabinets and network equipment. A listed input of 0.51 W is the model's notable electrical characteristic. For replacement evaluation, start with the supplied installation footprint. Check the full suffix before confirming connector details. |
12 | 50x50x15mm | 22.1 | 42.3 | 0.51 | 5000 | 29 | |
![]() MF25060V1-1000U-A99 | SUNON 5V 0.61W 25x25x6mm 3m3/h DC Axial Fan for Telecommunications The MF25060V1-1000U-A99 is SUNON's 5 VDC, 25 × 25 × 6 mm DC axial fan option for telecom cabinets and network equipment. Its 3 m³/h airflow rating suits the stated equipment-cooling role. Use the documented selection parameters when planning replacement evaluation. Check the full suffix before confirming connector details. |
5 | 25*25*6 | 3 | - | 0.61 | 13000 | 24.8 |
Choosing the right telecommunications starts with the operating point rather than the model name. Define the airflow you actually need in CFM or m³/h and the static pressure the fan must overcome, then look for units whose performance curves pass through that point with a safety margin instead of sitting at the edge of the curve.
Pay attention to the electrical details early. DC fans typically run on 12/24/48 V and integrate easily with control boards, while AC fans suit 115/230 V fixed-speed installations. If the airflow must change with load, choose EC technology with PWM or analog control and, where monitoring matters, a tachometer output so the controller can detect fan failure.
Environment and compliance come next. Match the IP rating to dust and moisture exposure, prefer ball bearings wherever the fan runs hot, vertically or around the clock, and confirm certifications — UL, CE, RoHS — against your destination market. Setting the acoustic limit in dBA early prevents late-stage redesign when the first unit proves too loud.
Finally, compare candidates on total delivery risk, not only on price: confirm stock for the quantity you need, check the lead time for the next batch, and ask for datasheets and dimension drawings before committing. Our team cross-checks curves, dimensions and electrical data for you before quotation There are currently 301 items in this category ready to compare.
Telecommunications appear in almost every sector where heat or stale air must be moved reliably. Typical environments include server rooms and data centers, refrigeration condensers and cold-store evaporators, HVAC air handling units, telecom cabinets, medical and laboratory equipment, welding and CNC machine enclosures, and renewable-energy power cabinets. In each of these settings the fan is a critical component: its failure stops production, damages stored goods or forces expensive emergency downtime.
One recurring scenario comes from control cabinet retrofits: the original fan is obsolete, the mounting hole pattern cannot change, and downtime is measured in hours. We match the old unit against current series by frame size, airflow and noise, propose the closest drop-in alternative, and ship with a datasheet that lets the electrician connect it without redesign.
For cold storage operators the pain is simple: a failed evaporator or condenser fan must be replaced now, not after a six-week import cycle. Matching blade diameter, speed and protection class against stocked equivalents lets us restore cooling capacity within days, which is why replacement supply has become a core part of this category for us.
Whether you are building new equipment or maintaining an installed base, the workflow is the same: send us the operating point and constraints, and we return a validated selection with datasheets, curves and a clear lead time.
Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 301 products in this category are listed online.
Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.
Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.