| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() MF17080V1-1000U-A99 | SUNON 5V 0.81W 17x17x8mm 0.9m3/h DC Axial Fan for Telecommunications For thermal management in telecom cabinets and network equipment, the MF17080V1-1000U-A99 provides a 5 VDC DC axial fan configuration measuring 17 × 17 × 8 mm. Its 0.9 m³/h airflow rating suits the stated equipment-cooling role. Review its rated dataset during replacement evaluation. Check the full suffix before confirming connector details. |
5 | 17*17*8 | 0.9 | - | 0.81 | 21000 | 21.5 | |
![]() MF40200V1-1000U-A99 | SUNON 5V 0.79W 40x40x20mm 8.9m3/h DC Axial Fan for Telecommunications SUNON MF40200V1-1000U-A99 combines a 40 × 40 × 20 mm DC axial fan platform with a 5 VDC rating for telecom cabinets and network equipment. Its 8.9 m³/h airflow rating suits the stated equipment-cooling role. Treat the motor input as a primary input to replacement evaluation. Check the full suffix before confirming connector details. |
5 | 40*40*20 | 8.9 | - | 0.79 | 7000 | 25.5 | |
![]() MF60252V1-1000U-A99 | SUNON 24V 1.25W 60x60x25mm 23.5m3/h DC Axial Fan for Telecommunications The MF60252V1-1000U-A99 is SUNON's 24 VDC, 60 × 60 × 25 mm DC axial fan option for telecom cabinets and network equipment. A listed noise value of 27 dB is the model's key differentiator. For replacement evaluation, start with the supplied catalog specification. Check the full suffix before confirming connector details. |
24 | 60*60*25 | 23.5 | - | 1.25 | 4500 | 27 | |
![]() MF60152V2-1000U-A99 | SUNON 24V 1.06W 60x60x15mm 22.8m3/h DC Axial Fan for Telecommunications A 60 × 60 × 15 mm frame and 24 VDC rating define MF60152V2-1000U-A99, a DC axial fan for telecom cabinets and network equipment. Its 22.8 m³/h airflow rating suits the stated equipment-cooling role. Use the documented thermal-duty record when planning replacement evaluation. Check the full suffix before confirming connector details. |
24 | 60*60*15 | 22.8 | - | 1.06 | 3900 | 29.2 | |
![]() MF30060V1-1000U-A99 | SUNON 5V 0.72W 30x30x6mm 4.9m3/h DC Axial Fan for Telecommunications SUNON MF30060V1-1000U-A99 combines a 30 × 30 × 6 mm DC axial fan platform with a 5 VDC rating for telecom cabinets and network equipment. Its 4.9 m³/h airflow rating suits the stated equipment-cooling role. Review its performance curve during replacement evaluation. Check the full suffix before confirming connector details. |
5 | 30*30*6 | 4.9 | - | 0.72 | 9100 | 23.6 | |
![]() MF50151V2-1000U-A99 | SUNON 12V 0.61W 50x50x15mm 22.1m3/h DC Axial Fan for Telecommunications Designed for telecom cabinets and network equipment, SUNON MF50151V2-1000U-A99 is a 12 VDC DC blower in a 50 × 50 × 15 mm frame. A listed input of 0.61 W is the model's notable electrical characteristic. Treat the mounting size as a primary input to replacement evaluation. Check the full suffix before confirming connector details. |
12 | 50*50*15 | 22.1 | - | 0.61 | 5000 | 29 | |
![]() MF30100V1-1000U-A99 | SUNON 5V 0.69W 30x30x10mm 5.5m3/h DC Axial Fan for Telecommunications MF30100V1-1000U-A99 serves telecom cabinets and network equipment as a 30 × 30 × 10 mm DC axial fan rated at 5 VDC. Its 5.5 m³/h airflow rating suits the stated equipment-cooling role. During replacement evaluation, compare the model's static-pressure entry. Check the full suffix before confirming connector details. |
5 | 30*30*10 | 5.5 | - | 0.69 | 11000 | 23 | |
![]() MF35100V1-1000U-A99 | SUNON 5V 0.78W 35x35x10mm 7.2m3/h DC Axial Fan for Telecommunications The MF35100V1-1000U-A99 is SUNON's 5 VDC, 35 × 35 × 10 mm DC axial fan option for telecom cabinets and network equipment. Its 7.2 m³/h airflow rating suits the stated equipment-cooling role. The recorded volume-flow figure should guide replacement evaluation. Check the full suffix before confirming connector details. |
5 | 35*35*10 | 7.2 | - | 0.78 | 10000 | 28 | |
![]() MF60151V2-1000U-A99 | SUNON 12V 0.88W 60x60x15mm 22.8m3/h DC Axial Fan for Telecommunications SUNON MF60151V2-1000U-A99 is a 12 VDC DC blower in a 60 × 60 × 15 mm format for telecom cabinets and network equipment. A listed input of 0.88 W is the model's notable electrical characteristic. For replacement evaluation, start with the supplied sound level. Check the full suffix before confirming connector details. |
12 | 60*60*15 | 22.8 | - | 0.88 | 3900 | 29.2 | |
![]() MF50152V2-1000U-A99 | SUNON 24V 0.72W 50x50x15mm 13m3/h DC Axial Fan for Telecommunications SUNON MF50152V2-1000U-A99 combines a 50 × 50 × 15 mm DC axial fan platform with a 24 VDC rating for telecom cabinets and network equipment. Its 13 m³/h airflow rating suits the stated equipment-cooling role. Use the documented rotational rating when planning replacement evaluation. Check the full suffix before confirming connector details. |
24 | 50*50*15 | 13 | - | 0.72 | 5000 | 29 | |
![]() MF40101V1-1000U-A99 | SUNON 12V 0.72W 40x40x10mm 8m3/h DC Axial Fan for Telecommunications Used in telecom cabinets and network equipment, SUNON MF40101V1-1000U-A99 is a 12 VDC DC axial fan in a 40 × 40 × 10 mm frame. Its 8 m³/h airflow rating suits the stated equipment-cooling role. Review its power demand during replacement evaluation. Check the full suffix before confirming connector details. |
12 | 40*40*10 | 8 | - | 0.72 | 7000 | 27.3 | |
![]() MF40201VX-1000U-A99 | SUNON 12V 1.06W 40x40x20mm 10.8m3/h DC Axial Fan for Telecommunications Within telecom cabinets and network equipment, SUNON MF40201VX-1000U-A99 serves as a 40 × 40 × 20 mm DC axial fan operating at 12 VDC. Its 10.8 m³/h airflow rating suits the stated equipment-cooling role. Treat the frame geometry as a primary input to replacement evaluation. Check the full suffix before confirming connector details. |
12 | 40*40*20 | 10.8 | - | 1.06 | 8000 | 27.5 | |
![]() MF20100V1-1000U-A99 | SUNON 5V 0.88W 20x20x10mm 1.9m3/h DC Axial Fan for Telecommunications MF20100V1-1000U-A99 addresses telecom cabinets and network equipment through a 5 VDC DC axial fan platform measuring 20 × 20 × 10 mm. Its 1.9 m³/h airflow rating suits the stated equipment-cooling role. Base replacement evaluation on the stated cooling output. Check the full suffix before confirming connector details. |
5 | 20*20*10 | 1.9 | - | 0.88 | 16500 | 25 | |
![]() MF40101VX-1000U-A99 | SUNON 12V 1.17W 40x40x10mm 9.9m3/h DC Axial Fan for Telecommunications The MF40101VX-1000U-A99 is SUNON's 12 VDC, 40 × 40 × 10 mm DC axial fan option for telecom cabinets and network equipment. Its 9.9 m³/h airflow rating suits the stated equipment-cooling role. During replacement evaluation, compare the model's operating point. Check the full suffix before confirming connector details. |
12 | 40*40*10 | 9.9 | - | 1.17 | 8000 | 31.4 | |
![]() MF80251V1-1000U-G99 | SUNON 12V 1.44W 80x80x25mm 69.7m3/h DC Axial Fan for Telecommunications For compact cooling within telecom cabinets and network equipment, the MF80251V1-1000U-G99 provides a 12 VDC DC axial fan configuration measuring 80 × 80 × 25 mm. Its 3200 rpm rating defines a lower-speed operating point. The recorded pressure capability should guide replacement evaluation. Check the full suffix before confirming connector details. |
12 | 80*80*25 | 69.7 | - | 1.44 | 3200 | 33 | |
![]() MF20080V1-1000U-A99 | SUNON 5V 0.72W 20x20x8mm 1.6m3/h DC Axial Fan for Telecommunications Within telecom cabinets and network equipment, SUNON MF20080V1-1000U-A99 serves as a 20 × 20 × 8 mm DC axial fan operating at 5 VDC. Its 1.6 m³/h airflow rating suits the stated equipment-cooling role. Review its electrical load during replacement evaluation. Check the full suffix before confirming connector details. |
5 | 20*20*8 | 1.6 | - | 0.72 | 15000 | 23 | |
![]() MF50152V1-1000U-G99 | SUNON 24V 1.08W 50x50x15mm 17m3/h DC Axial Fan for Telecommunications For thermal management in telecom cabinets and network equipment, the MF50152V1-1000U-G99 provides a 24 VDC DC axial fan configuration measuring 50 × 50 × 15 mm. Its 17 m³/h airflow rating suits the stated equipment-cooling role. During enclosure sizing, compare the model's application data. Verify bearing and signal options in the exact datasheet. |
24 | 50*50*15 | 17 | - | 1.08 | 6100 | 33 | |
![]() MF60152VX-1000U-A99 | SUNON 24V 2.04W 60x60x15mm 30.4m3/h DC Axial Fan for Telecommunications Positioned for telecom cabinets and network equipment, SUNON MF60152VX-1000U-A99 is a 24 VDC DC axial fan in a 60 × 60 × 15 mm frame. Its 30.4 m³/h airflow rating suits the stated equipment-cooling role. For enclosure sizing, start with the supplied model record. Verify bearing and signal options in the exact datasheet. |
24 | 60*60*15 | 30.4 | - | 2.04 | 5400 | 36.2 | |
![]() MF50151V1-1000U-G99 | SUNON 12V 0.92W 50x50x15mm 17m3/h DC Axial Fan for Telecommunications SUNON MF50151V1-1000U-G99 combines a 50 × 50 × 15 mm DC blower platform with a 12 VDC rating for telecom cabinets and network equipment. Its 17 m³/h airflow rating suits the stated equipment-cooling role. During enclosure sizing, compare the model's installation footprint. Verify bearing and signal options in the exact datasheet. |
12 | 50*50*15 | 17 | - | 0.92 | 6100 | 33 | |
![]() MF40201VX-1000U-G99 | SUNON 12V 0.96W 40x40x20mm 18.3m3/h DC Axial Fan for Telecommunications Built around telecom cabinets and network equipment, SUNON MF40201VX-1000U-G99 is a 12 VDC DC axial fan in a 40 × 40 × 20 mm frame. 8000 rpm is the model's most distinctive operating parameter. The recorded selection parameters should guide enclosure sizing. Verify bearing and signal options in the exact datasheet. |
12 | 40x40x20 | 18.3 | 72.2 | 0.96 | 8000 | 27.5 |
Choosing the right telecommunications starts with the operating point rather than the model name. Define the airflow you actually need in CFM or m³/h and the static pressure the fan must overcome, then look for units whose performance curves pass through that point with a safety margin instead of sitting at the edge of the curve.
Pay attention to the electrical details early. DC fans typically run on 12/24/48 V and integrate easily with control boards, while AC fans suit 115/230 V fixed-speed installations. If the airflow must change with load, choose EC technology with PWM or analog control and, where monitoring matters, a tachometer output so the controller can detect fan failure.
Environment and compliance come next. Match the IP rating to dust and moisture exposure, prefer ball bearings wherever the fan runs hot, vertically or around the clock, and confirm certifications — UL, CE, RoHS — against your destination market. Setting the acoustic limit in dBA early prevents late-stage redesign when the first unit proves too loud.
Finally, compare candidates on total delivery risk, not only on price: confirm stock for the quantity you need, check the lead time for the next batch, and ask for datasheets and dimension drawings before committing. Our team cross-checks curves, dimensions and electrical data for you before quotation There are currently 301 items in this category ready to compare.
Telecommunications appear in almost every sector where heat or stale air must be moved reliably. Typical environments include server rooms and data centers, refrigeration condensers and cold-store evaporators, HVAC air handling units, telecom cabinets, medical and laboratory equipment, welding and CNC machine enclosures, and renewable-energy power cabinets. In each of these settings the fan is a critical component: its failure stops production, damages stored goods or forces expensive emergency downtime.
One recurring scenario comes from control cabinet retrofits: the original fan is obsolete, the mounting hole pattern cannot change, and downtime is measured in hours. We match the old unit against current series by frame size, airflow and noise, propose the closest drop-in alternative, and ship with a datasheet that lets the electrician connect it without redesign.
For cold storage operators the pain is simple: a failed evaporator or condenser fan must be replaced now, not after a six-week import cycle. Matching blade diameter, speed and protection class against stocked equivalents lets us restore cooling capacity within days, which is why replacement supply has become a core part of this category for us.
Whether you are building new equipment or maintaining an installed base, the workflow is the same: send us the operating point and constraints, and we return a validated selection with datasheets, curves and a clear lead time.
Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 301 products in this category are listed online.
Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.
Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.