Mfr Part # Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
MF25100V1-1000U-A99 | SUNON 5V 0.58W 25x25x10mm 3.5m3/h DC Axial Fan for Telecommunications

Within telecom cabinets and network equipment, SUNON MF25100V1-1000U-A99 serves as a 25 × 25 × 10 mm DC axial fan operating at 5 VDC. Its 3.5 m³/h airflow rating suits the stated equipment-cooling role. For enclosure sizing, start with the supplied rated dataset. Verify bearing and signal options in the exact datasheet.

5 25*25*10 3.5 - 0.58 13000 23
MF40100V1-1000U-A99 | SUNON 5V 0.83W 40x40x10mm 8m3/h DC Axial Fan for Telecommunications

SUNON MF40100V1-1000U-A99 combines a 40 × 40 × 10 mm DC axial fan platform with a 5 VDC rating for telecom cabinets and network equipment. Its 8 m³/h airflow rating suits the stated equipment-cooling role. Base enclosure sizing on the stated suffix definition. Verify bearing and signal options in the exact datasheet.

5 40*40*10 8 - 0.83 7000 27.3
MF60251V1-1000U-A99 | SUNON 12V 0.96W 60x60x25mm 23.5m3/h DC Axial Fan for Telecommunications

Within telecom cabinets and network equipment, SUNON MF60251V1-1000U-A99 serves as a 60 × 60 × 25 mm DC axial fan operating at 12 VDC. A listed noise value of 27 dB is the model's key differentiator. The recorded thermal-duty record should guide enclosure sizing. Verify bearing and signal options in the exact datasheet.

12 60*60*25 23.5 - 0.96 4500 27
MF50151V1-1000U-A99 | SUNON 12V 0.92W 50x50x15mm 17m3/h DC Axial Fan for Telecommunications

The MF50151V1-1000U-A99 is SUNON's 12 VDC, 50 × 50 × 15 mm DC blower option for telecom cabinets and network equipment. Its 17 m³/h airflow rating suits the stated equipment-cooling role. Use the documented mounting size when planning enclosure sizing. Verify bearing and signal options in the exact datasheet.

12 50*50*15 17 - 0.92 6100 33
MF60152V1-1000U-A99 | SUNON 24V 2.02W 60x60x15mm 26.4m3/h DC Axial Fan for Telecommunications

For compact cooling within telecom cabinets and network equipment, the MF60152V1-1000U-A99 provides a 24 VDC DC axial fan configuration measuring 60 × 60 × 15 mm. Its 26.4 m³/h airflow rating suits the stated equipment-cooling role. Review its supply requirement during enclosure sizing. Verify bearing and signal options in the exact datasheet.

24 60*60*15 26.4 - 2.02 4700 34.2
MF50151VX-B00U-A99 | SUNON 12V 2.04W 50x50x15mm 5.4m3/h DC Axial Fan for Telecommunications

Engineered for telecom cabinets and network equipment, SUNON MF50151VX-B00U-A99 is a 12 VDC DC blower in a 50 × 50 × 15 mm frame. Its 5.4 m³/h airflow rating suits the stated equipment-cooling role. Base enclosure sizing on the stated volume-flow figure. Verify bearing and signal options in the exact datasheet.

12 50*50*15 5.4 - 2.04 6000 42.2
MF80252V1-1000U-A99 | SUNON 24V 1.68W 80x80x25mm 41m3/h DC Axial Fan for Telecommunications

Within telecom cabinets and network equipment, SUNON MF80252V1-1000U-A99 serves as a 80 × 80 × 25 mm DC axial fan operating at 24 VDC. Its 3200 rpm rating defines a lower-speed operating point. During enclosure sizing, compare the model's sound level. Verify bearing and signal options in the exact datasheet.

24 80*80*25 41 - 1.68 3200 33
MF25101V1-1000U-A99 | SUNON 12V 0.87W 25x25x10mm 3.8m3/h DC Axial Fan for Telecommunications

The MF25101V1-1000U-A99 is SUNON's 12 VDC, 25 × 25 × 10 mm DC axial fan option for telecom cabinets and network equipment. Its 3.8 m³/h airflow rating suits the stated equipment-cooling role. For enclosure sizing, start with the supplied power demand. Verify bearing and signal options in the exact datasheet.

12 25*25*10 3.8 - 0.87 14000 26
MF40202V2-1000U-A99 | SUNON 24V 0.68W 40x40x20mm 7.7m3/h DC Axial Fan for Telecommunications

Within telecom cabinets and network equipment, SUNON MF40202V2-1000U-A99 serves as a 40 × 40 × 20 mm DC axial fan operating at 24 VDC. Its 7.7 m³/h airflow rating suits the stated equipment-cooling role. Base enclosure sizing on the stated pressure capability. Verify bearing and signal options in the exact datasheet.

24 40*40*20 7.7 - 0.68 6200 21
MF60101V1-1000U-A99 | SUNON 12V 1.42W 60x60x10mm 16.3m3/h DC Axial Fan for Telecommunications

Within telecom cabinets and network equipment, MF60101V1-1000U-A99 provides a 60 × 60 × 10 mm, 12 VDC DC axial fan configuration. Its 16.3 m³/h airflow rating suits the stated equipment-cooling role. During enclosure sizing, compare the model's dimensional envelope. Verify bearing and signal options in the exact datasheet.

12 60*60*10 16.3 - 1.42 4000 28.5
R1G225-AF11-30 | ebm-papst 48V 95W Centrifugal Fan for Telecom

Intended for Telecom, ebm-papst R1G225-AF11-30 is a 48 V EC forward-curved centrifugal fan, characterized by a documented speed of 2,700 rpm. The value helps verify equipment fit. Its documented data supports integration planning.

48 225 1210 442 95 2700 -
R1G310-AD33-30 | ebm-papst 48V 90W Centrifugal Fan for Telecom

Designed for Telecom, ebm-papst R1G310-AD33-30 is a 48 V EC forward-curved centrifugal fan, featuring a documented 90 W input rating. This supports duty-point selection. Its documented data supports integration planning.

48 310 2065 285 90 1600 64
R1G133-AA65-36 | ebm-papst 48V 28W Centrifugal Fan for Telecom

Designed for Telecom, the ebm-papst R1G133-AA65-36 is a 48 V EC forward-curved centrifugal fan, distinguished by a documented speed of 3,900 rpm. The rating clarifies its operating profile.

48 133 415 350 28 3900 -
R1G225-AF11-38 | ebm-papst 48V Centrifugal Fan for Telecom

Applied in Telecom, the ebm-papst R1G225-AF11-38 is a 48 V EC forward-curved centrifugal fan, characterized by 225 mm dimensions for installation planning. This helps guide installation planning.

48 225 - - - - -
R1G175-RB33-10 | ebm-papst 48V 75W Centrifugal Fan for Telecom

Developed for Telecom, the ebm-papst R1G175-RB33-10 is a 48 V EC forward-curved centrifugal fan, identified by a documented speed of 3,950 rpm. This enables specification-led selection.

48 175 695 450 75 3950 -
R1G220-AB73-52 | ebm-papst 48V 100W Centrifugal Fan for Telecom

Used in Telecom, ebm-papst R1G220-AB73-52 is a 48 V EC forward-curved centrifugal fan, offering a documented speed of 3,100 rpm. This assists electrical and mechanical review. Its documented data supports integration planning.

48 220 1080 508 100 3100 -
R1G220-AB35-52 | ebm-papst 24V 106W Centrifugal Fan for Telecom

Suited to Telecom, ebm-papst R1G220-AB35-52 is a 24 V EC forward-curved centrifugal fan, noted for a documented speed of 3,150 rpm. The data supports model-level evaluation. Its documented data supports integration planning.

24 220 1055 700 106 3150 76
R1G175-RB33-G01 | ebm-papst 48V 76W Centrifugal Fan for Telecom

Specified for Telecom, ebm-papst R1G175-RB33-G01 is a 48 V EC forward-curved centrifugal fan, defined by a documented speed of 3,950 rpm. The data helps compare K-series variants. Its documented data supports integration planning.

48 175 675 450 76 3950 -
R1G175-AB41-64 | ebm-papst 48V 34W Centrifugal Fan for Telecom

Engineered around Telecom, ebm-papst R1G175-AB41-64 is a 48 V EC forward-curved centrifugal fan, with a documented speed of 3,100 rpm. The rating clarifies its operating profile. Its documented data supports integration planning.

48 175 - - 34 3100 -
R1G175-AB41-34 | ebm-papst 48V 34W Centrifugal Fan for Telecom

Used in Telecom, ebm-papst R1G175-AB41-34 is a 48 V EC forward-curved centrifugal fan, identified by a documented speed of 3,100 rpm. This enables specification-led selection. Its documented data supports integration planning.

48 175 - 321 34 3100 -
Showing
281-300
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-301
of 301
1 2 ... 7 8 9 10 11 12 13 14 15 16
GO page

About Telecommunications

How to Select the Right Telecommunications

Choosing the right telecommunications starts with the operating point rather than the model name. Define the airflow you actually need in CFM or m³/h and the static pressure the fan must overcome, then look for units whose performance curves pass through that point with a safety margin instead of sitting at the edge of the curve.

Pay attention to the electrical details early. DC fans typically run on 12/24/48 V and integrate easily with control boards, while AC fans suit 115/230 V fixed-speed installations. If the airflow must change with load, choose EC technology with PWM or analog control and, where monitoring matters, a tachometer output so the controller can detect fan failure.

Environment and compliance come next. Match the IP rating to dust and moisture exposure, prefer ball bearings wherever the fan runs hot, vertically or around the clock, and confirm certifications — UL, CE, RoHS — against your destination market. Setting the acoustic limit in dBA early prevents late-stage redesign when the first unit proves too loud.

Finally, compare candidates on total delivery risk, not only on price: confirm stock for the quantity you need, check the lead time for the next batch, and ask for datasheets and dimension drawings before committing. Our team cross-checks curves, dimensions and electrical data for you before quotation There are currently 301 items in this category ready to compare.

Typical Applications and Use Cases for Telecommunications

Telecommunications appear in almost every sector where heat or stale air must be moved reliably. Typical environments include server rooms and data centers, refrigeration condensers and cold-store evaporators, HVAC air handling units, telecom cabinets, medical and laboratory equipment, welding and CNC machine enclosures, and renewable-energy power cabinets. In each of these settings the fan is a critical component: its failure stops production, damages stored goods or forces expensive emergency downtime.

One recurring scenario comes from control cabinet retrofits: the original fan is obsolete, the mounting hole pattern cannot change, and downtime is measured in hours. We match the old unit against current series by frame size, airflow and noise, propose the closest drop-in alternative, and ship with a datasheet that lets the electrician connect it without redesign.

For cold storage operators the pain is simple: a failed evaporator or condenser fan must be replaced now, not after a six-week import cycle. Matching blade diameter, speed and protection class against stocked equivalents lets us restore cooling capacity within days, which is why replacement supply has become a core part of this category for us.

Whether you are building new equipment or maintaining an installed base, the workflow is the same: send us the operating point and constraints, and we return a validated selection with datasheets, curves and a clear lead time.

Frequently Asked Questions About Buying Telecommunications

Do you have telecommunications in stock and how fast can you deliver?

Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 301 products in this category are listed online.

Can you replace my existing telecommunications from another supplier or a discontinued model?

Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.

Can I order a single piece or request a sample before a bulk purchase?

Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.

Bag

Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.