The GF92382BX-10000-ADP is SUNON's 24 VDC, 92 × 92 × 38 mm DC axial fan option for inverters, energy-storage systems, and charging equipment. Up to 293.8 m³/h is its most prominent listed performance figure. Review its selection parameters during spares assessment. Confirm control inputs against the complete ordering code.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 92x92x38mm |
| Max.Air Flow(m³/h) | 293.8 |
| Max.Pressure(Pa) | 430.9 |
| Input Power(W) | 40.8 |
| Speed(rpm) | 9000 |
| Noise(db) | 66.8 |
For new-energy power equipment, SUNON GF92382BX-10000-ADP serves as a DC brushless axial fan. The fan supports temperature control in equipment that runs through sustained or repeated duty cycles.
The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market. Correct airflow direction and inlet clearance help translate the documented operating point into reliable equipment-level cooling.
Before adopting GF92382BX-10000-ADP, engineers should evaluate mounting rigidity. Carry out power-budget review during sourcing review so the chosen fan can be released with clear installation and sourcing requirements. Confirm startup and steady-state demand against the available supply.
SUNON GF92382BX-10000-ADP serves energy-storage systems. Airflow around battery-control and power-conversion assemblies helps address charging and discharging losses. The fan gives OEM equipment a defined air route and supports stable ESS operation. It supports reliable equipment cooling.
SUNON GF92382BX-10000-ADP serves photovoltaic inverters. Airflow around switching devices and control electronics helps address solar power-conversion heat. The fan gives OEM equipment a defined air route and supports dependable inverter duty. It supports reliable equipment cooling.
SUNON GF92382BX-10000-ADP serves electric-vehicle charging equipment. Airflow around power modules and control assemblies helps address high charging loads. The fan gives OEM equipment a defined air route and supports reliable charging operation. It supports reliable equipment cooling.
The supplied product-line reference discusses long-life cooling, but continuous-duty limits for this full suffix must be verified from its datasheet and operating conditions.
Yes. The worksheet lists up to 430.9 Pa; compare it with the system curve.
Use the listed voltage, size, 293.8 m³/h airflow, 9000 rpm, and 40.8 W input for preliminary comparison.
The workbook marks the product as RoHS compliant. Confirm UL, TUV, VDE, or other project-specific approvals for the exact suffix.
The exact IP or protection option is not stated in the supplied row. Confirm the full suffix in the applicable SUNON datasheet.
Speed-control capability is not stated for this complete part number. Confirm the signal and controller requirements before use.

Used in servers and data-center electronics, SUNON GF40282BX-10000-ADP is a 24 VDC DC axial fan in a 40 × 40 × 28 mm frame. 500.7 Pa maximum pressure is the standout documented duty-point value. The recorded power demand should guide cooling-margin review. Check the full suffix before confirming connector details.
Read More
SUNON configures GF40282B3-10000-ADP as a 40 × 40 × 28 mm DC axial fan for servers and data-center electronics, operating at 24 VDC. Its 500 rpm rating defines a lower-speed operating point. Treat the pressure capability as a primary input to cooling-margin review. Check the full suffix before confirming connector details.
Read More
For servers and data-center electronics, GF40282B2-10000-ADP combines 24 VDC operation with a 40 × 40 × 28 mm DC axial fan design. 276.5 Pa maximum pressure is the standout documented duty-point value. For cooling-margin review, start with the supplied speed benchmark. Check the full suffix before confirming connector details.
Read More
Positioned for servers and data-center electronics, SUNON GF40282B1-10000-ADP is a 24 VDC DC axial fan in a 40 × 40 × 28 mm frame. 343.7 Pa maximum pressure is the standout documented duty-point value. Base cabinet ventilation planning on the stated model record. Verify bearing and signal options in the exact datasheet.
Read More
Within servers and data-center electronics, SUNON GF40282B3-10000-SDP serves as a 40 × 40 × 28 mm DC axial fan operating at 24 VDC. 10500 W input is the defining electrical load in the supplied data. For cooling-margin review, start with the supplied frame geometry. Check the full suffix before confirming connector details.
Read More
GF40282B3-10000-QDP addresses servers and data-center electronics through a 24 VDC DC axial fan platform measuring 40 × 40 × 28 mm. 10500 W input is the defining electrical load in the supplied data. Use the documented cooling output when planning cooling-margin review. Check the full suffix before confirming connector details.
Read More