| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() 9GV0412P3J03 | Sanyo Denki 12VDC 7.2W DC Axial Fan for automation and control cabinet cooling For industrial controls, power cabinets, and energy systems, 9GV0412P3J03 combines 12 VDC operation with a 40 × 40 × 28 mm DC axial fan design. Series focus: high airflow and pressure. 14700 rpm is the model's most prominent operating value. Check procurement data comparison static-pressure entry. Focus: procurement data comparison. |
12 | 40*40*28 | 40.3 | 330 | 7.2 | 14700 | 55 | |
![]() 109P0412G3D083 | Sanyo Denki 12VDC DC Axial Fan for UPS, server and telecom equipment cooling The 109P0412G3D083 is a Sanyo Denki 12 VDC, 40 × 40 × 28 mm DC axial fan for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. The recorded operating point should guide spares assessment. Match the exact part number before approving a substitute. Focus: procurement data comparison. |
12 | 40*40*28 | - | - | - | - | - | |
![]() 109P0424B302 | Sanyo Denki 24VDC 3.12W DC Axial Fan for UPS, server and telecom equipment cooling The 40 × 40 × 28 mm Sanyo Denki 109P0424B302 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. For thermal validation, start with the supplied pressure capability. Use current model documentation to validate protection choices. Focus: procurement data comparison sound level. |
24 | 40*40*28 | - | - | 3.12 | 10300 | 40 | |
![]() 9HVA0412P3J001 | Sanyo Denki 12VDC 31.2W DC Axial Fan for AI servers and high-density equipment cooling 9HVA0412P3J001 serves AI servers and high-density electronics as a 40 × 40 × 28 mm DC axial fan rated at 12 VDC. Ultra-high static-pressure capability is the representative series characteristic. 2300 Pa maximum pressure is the most distinctive duty-point parameter. Check procurement data comparison rotational rating. |
12 | 40*40*28 | 63.07 | 2300 | 31.2 | 38000 | 71 | |
![]() 109P0424H338 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling Equipment designers serving servers, UPS systems, and telecom equipment can evaluate Sanyo Denki 109P0424H338, a DC axial fan rated at 24 VDC and sized 40 × 40 × 28 mm. The 40 × 40 × 28 mm format is the primary stated selection detail. Base wiring review on the stated power demand. Match the exact part number before approving a substitute. |
24 | 40*40*28 | - | - | - | - | - | |
![]() 9GV5748LF503 | Sanyo Denki 48VDC DC Axial Fan for automation and control cabinet cooling Sanyo Denki 9GV5748LF503 combines a 172 × 150 × 51 mm DC axial fan platform with a 48 VDC rating for industrial controls, power cabinets, and energy systems. High airflow is highlighted together with a high-static-pressure design. The 172 × 150 × 51 mm format is the primary stated selection detail. Focus: procurement data comparison frame geometry. |
48 | 172*150*51 | - | - | - | - | - | |
![]() 109P0424H6D21 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling The 109P0424H6D21 is a Sanyo Denki 24 VDC, 40 × 40 × 20 mm DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Use the documented catalog specification when planning enclosure sizing. Use the latest specification for frequency and tolerance limits. Focus: procurement data comparison cooling output. |
24 | 40*40*20 | - | - | - | - | - | |
![]() 109P0424H6D01 | Sanyo Denki 24VDC 1.68W DC Axial Fan for UPS, server and telecom equipment cooling For servers, UPS systems, and telecom equipment, 109P0424H6D01 combines 24 VDC operation with a 40 × 40 × 20 mm DC axial fan design. Series focus: high airflow and pressure. The 13.94 m³/h airflow figure supports its stated equipment-cooling role. Check procurement data comparison operating point. Focus: procurement data comparison operating point. |
24 | 40*40*20 | 13.94 | 69.7 | 1.68 | 8300 | 35 | |
![]() 9GV1224J102 | Sanyo Denki 24VDC 36W DC Axial Fan for automation and control cabinet cooling The 24 VDC Sanyo Denki 9GV1224J102 is a DC axial fan sized 120 × 120 × 38 mm for industrial controls, power cabinets, and energy systems. High airflow is highlighted together with a high-static-pressure design. The supplied row lists 64 dB as an important acoustic selection value. Selection focus: procurement data comparison pressure capability. |
24 | 120*120*38 | 376.2 | 361.2 | 36 | 6400 | 64 | |
![]() 9GA0824J40021 | Sanyo Denki 24VDC 6.72W DC Axial Fan for UPS, server and telecom equipment cooling The 9GA0824J40021 is a Sanyo Denki 24 VDC, 80 × 80 × 25.2 mm DC axial fan for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. The recorded speed benchmark should guide enclosure sizing. Confirm control inputs against the complete ordering code. |
24 | 80*80*25.2 | 122.4 | 174.4 | 6.72 | 7400 | 48 | |
![]() 9GV1248P4G041 | Sanyo Denki 48VDC DC Axial Fan for automation and control cabinet cooling The 9GV1248P4G041 is a Sanyo Denki 48 VDC, 120 × 120 × 25 mm DC axial fan for industrial controls, power cabinets, and energy systems. Series focus: high airflow and pressure. Review its cooling specification during spares assessment. Use the latest specification for frequency and tolerance limits. Focus: procurement data comparison acoustic value. |
48 | 120*120*25 | - | - | - | - | - | |
![]() 109E5724K5H01 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling The 172 × 150 × 51 mm Sanyo Denki 109E5724K5H01 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. During thermal validation, compare the model's operating point. Treat bearing and life data as suffix-specific. |
24 | 172*150*51 | - | - | - | - | - | |
![]() 9GV0824P1G031 | Sanyo Denki 24VDC 38.4W DC Axial Fan for automation and control cabinet cooling For industrial controls, power cabinets, and energy systems, 9GV0824P1G031 combines 24 VDC operation with a 80 × 80 × 38 mm DC axial fan design. High airflow is highlighted together with a high-static-pressure design. 38.4 W input is the defining electrical-load figure. Check procurement data comparison speed benchmark. |
24 | 80*80*38 | 234.6 | 490.7 | 38.4 | 10200 | 65 | |
![]() 9A0824S402 | Sanyo Denki 24VDC 2.4W DC Axial Fan for UPS, server and telecom equipment cooling 9A0824S402 addresses servers, UPS systems, and telecom equipment through a 24 VDC DC axial fan platform measuring 80 × 80 × 25 mm. Series focus: high airflow and pressure. 48.1 Pa maximum pressure is the most distinctive duty-point parameter. Check procurement data comparison airflow profile. Focus: procurement data comparison airflow profile. |
24 | 80*80*25 | 71.4 | 48.1 | 2.4 | 3400 | 34 | |
![]() 9GA0424P3M001 | Sanyo Denki 24VDC 2.64W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki configures 9GA0424P3M001 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 40 × 40 × 28 mm dimensions. 12500 rpm is the model's most prominent operating value. For airflow-path design, start with the supplied system interface. Obtain the applicable curve before final duty-point approval. |
24 | 40*40*28 | 28 | 258 | 2.64 | 12500 | 47 | |
![]() 9HV1224P1A001 | Sanyo Denki 24VDC 57.6W DC Axial Fan for AI servers and high-density equipment cooling Sanyo Denki configures 9HV1224P1A001 for AI servers and high-density electronics as a 24 VDC DC axial fan with 120×120×38 mm dimensions. The supplied row lists 71 dB as an important acoustic selection value. During fan selection, compare the model's equipment fit. Review connector, alarm, and sensor options separately. |
24 | 120×120×38 | 420 | 950 | 57.6 | 9600 | 71 | |
![]() 9GL1248H1D01 | Sanyo Denki 48VDC 5.28W DC Axial Fan for UPS, server and telecom equipment cooling The 48 VDC Sanyo Denki 9GL1248H1D01 is a DC axial fan sized 120 × 120 × 38 mm for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Its 2600 rpm rating defines a lower-speed operating point. Check thermal margin assessment installation footprint. Focus: thermal margin assessment installation footprint. |
48 | 120*120*38 | 166.2 | 70.5 | 5.28 | 2600 | 39 | |
![]() 9G1211G1D01 | Sanyo Denki 12VDC 11.76W DC Axial Fan for UPS, server and telecom equipment cooling For servers, UPS systems, and telecom equipment, 9G1211G1D01 combines 12 VDC operation with a 120 × 120 × 38 mm DC axial fan design. High airflow is highlighted together with a high-static-pressure design. Its listed airflow of 232.9 m³/h is the standout performance value. Check thermal margin assessment selection parameters. |
12 | 120*120*38 | 232.9 | 135 | 11.76 | 3600 | 49 | |
![]() 9SG5748P5H01 | Sanyo Denki 48VDC 78W DC Axial Fan for UPS, server and telecom equipment cooling The 172 × 150 × 51 mm Sanyo Denki 9SG5748P5H01 brings 48 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. For maintenance preparation, start with the supplied selection parameters. Review connector, alarm, and sensor options separately. Focus: thermal margin assessment motor input. |
48 | 172*150*51 | 697 | 770 | 78 | 6500 | 71 | |
![]() 109P0424H3D18 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling The 24 VDC Sanyo Denki 109P0424H3D18 is a DC axial fan sized 40 × 40 × 20 mm for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. The 40 × 40 × 20 mm format is the primary stated selection detail. Check thermal margin assessment ventilation capacity. |
24 | 40*40*20 | - | - | - | - | - |
Choosing the right automation starts with the operating point rather than the model name. Define the airflow you actually need in CFM or m³/h and the static pressure the fan must overcome, then look for units whose performance curves pass through that point with a safety margin instead of sitting at the edge of the curve.
Pay attention to the electrical details early. DC fans typically run on 12/24/48 V and integrate easily with control boards, while AC fans suit 115/230 V fixed-speed installations. If the airflow must change with load, choose EC technology with PWM or analog control and, where monitoring matters, a tachometer output so the controller can detect fan failure.
Environment and compliance come next. Match the IP rating to dust and moisture exposure, prefer ball bearings wherever the fan runs hot, vertically or around the clock, and confirm certifications — UL, CE, RoHS — against your destination market. Setting the acoustic limit in dBA early prevents late-stage redesign when the first unit proves too loud.
Finally, compare candidates on total delivery risk, not only on price: confirm stock for the quantity you need, check the lead time for the next batch, and ask for datasheets and dimension drawings before committing. Our team cross-checks curves, dimensions and electrical data for you before quotation There are currently 1,154 items in this category ready to compare.
Automation appear in almost every sector where heat or stale air must be moved reliably. Typical environments include server rooms and data centers, refrigeration condensers and cold-store evaporators, HVAC air handling units, telecom cabinets, medical and laboratory equipment, welding and CNC machine enclosures, and renewable-energy power cabinets. In each of these settings the fan is a critical component: its failure stops production, damages stored goods or forces expensive emergency downtime.
One recurring scenario comes from control cabinet retrofits: the original fan is obsolete, the mounting hole pattern cannot change, and downtime is measured in hours. We match the old unit against current series by frame size, airflow and noise, propose the closest drop-in alternative, and ship with a datasheet that lets the electrician connect it without redesign.
For cold storage operators the pain is simple: a failed evaporator or condenser fan must be replaced now, not after a six-week import cycle. Matching blade diameter, speed and protection class against stocked equivalents lets us restore cooling capacity within days, which is why replacement supply has become a core part of this category for us.
Whether you are building new equipment or maintaining an installed base, the workflow is the same: send us the operating point and constraints, and we return a validated selection with datasheets, curves and a clear lead time.
Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.
Every unit is covered by the manufacturer's warranty against defects in materials and workmanship, and we support you through the whole claim process so you deal with one supplier instead of chasing a factory overseas. If a failure appears in service, send us the serial number, operating conditions and photos, and we will arrange the replacement or credit path agreed in the quotation.
Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.