| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() 9CR5748P9G003 | Sanyo Denki 48VDC Counter-Rotating DC Axial Fan for UPS, server and telecom equipment cooling 9CR5748P9G003 serves servers, UPS systems, and telecom equipment as a 172 × 150 × 102 mm DC axial fan rated at 48 VDC. The series cooling function is confirmed; suffix-specific options require datasheet verification. The 172 × 150 × 102 mm format is the primary stated selection detail. Selection focus: lifecycle requirement review sound level. |
48 | 172*150*102 | - | - | - | - | - | |
![]() 109P0424F602 | Sanyo Denki 24VDC 1.44W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki configures 109P0424F602 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 40 × 40 × 20 mm dimensions. The 10.9 m³/h airflow figure supports its stated equipment-cooling role. Review its airflow profile during airflow-path design. Obtain the applicable curve before final duty-point approval. |
24 | 40*40*20 | 10.9 | 45.1 | 1.44 | 6500 | 28 | |
![]() 9G0624S4002 | Sanyo Denki 24VDC 8.16W DC Axial Fan for UPS, server and telecom equipment cooling Equipment designers serving servers, UPS systems, and telecom equipment can evaluate Sanyo Denki 9G0624S4002, a DC axial fan rated at 24 VDC and sized 60 × 60 × 25 mm. 11000 rpm is the model's most prominent operating value. Treat the acoustic value as a primary input to airflow-path design. Treat bearing and life data as suffix-specific. |
24 | 60*60*25 | 82.8 | 298.9 | 8.16 | 11000 | 53 | |
![]() 9G1224H1011 | Sanyo Denki 24VDC 5.28W DC Axial Fan for UPS, server and telecom equipment cooling For thermal management in servers, UPS systems, and telecom equipment, the 9G1224H1011 provides a 24 VDC DC axial fan configuration measuring 119 × 119 × 38 mm. Its 2600 rpm rating defines a lower-speed operating point. Treat the equipment fit as a primary input to controller selection. Validate mounting and wiring from the model drawing. |
24 | 119*119*38 | 166.2 | 70.5 | 5.28 | 2600 | 39 | |
![]() 9G1212H4021 | Sanyo Denki 12VDC 3.72W DC Axial Fan for UPS, server and telecom equipment cooling For thermal management in servers, UPS systems, and telecom equipment, the 9G1212H4021 provides a 12 VDC DC axial fan configuration measuring 119 × 119 × 25 mm. Its 2850 rpm rating defines a lower-speed operating point. Use the documented mounting size when planning service-life planning. Treat bearing and life data as suffix-specific. |
12 | 119*119*25 | 147.6 | 64 | 3.72 | 2850 | 40 | |
![]() 9G1224F401 | Sanyo Denki 24VDC 2.4W DC Axial Fan for UPS, server and telecom equipment cooling 9G1224F401 serves servers, UPS systems, and telecom equipment as a 119 × 119 × 25 mm DC axial fan rated at 24 VDC. High airflow is highlighted together with a high-static-pressure design. Its 2250 rpm rating defines a lower-speed operating point. Check lifecycle requirement review dimensional envelope. Focus: lifecycle requirement review. |
24 | 119*119*25 | 119 | 42.1 | 2.4 | 2250 | 35 | |
![]() 9GA0424G3001 | Sanyo Denki 24VDC 5.28W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki configures 9GA0424G3001 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 40 × 40 × 28 mm dimensions. 16500 rpm is the model's most prominent operating value. Use the documented airflow profile when planning equipment integration. Review connector, alarm, and sensor options separately. |
24 | 40*40*28 | 36.1 | 450.8 | 5.28 | 16500 | 53 | |
![]() 9GA0424P3M0011 | Sanyo Denki 24VDC 2.64W DC Axial Fan for UPS, server and telecom equipment cooling For thermal management in servers, UPS systems, and telecom equipment, the 9GA0424P3M0011 provides a 24 VDC DC axial fan configuration measuring 40×40×28 mm. 12500 rpm is the model's most prominent operating value. Base procurement comparison on the stated motor input. Confirm control inputs against the complete ordering code. |
24 | 40×40×28 | 27.6 | 258 | 2.64 | 12500 | 47 | |
![]() 9S0812M4011 | Sanyo Denki 12VDC 0.96W DC Axial Fan for UPS, server and telecom equipment cooling Within servers, UPS systems, and telecom equipment, 9S0812M4011 provides a 80×80×25 mm, 12 VDC DC axial fan configuration. High airflow is highlighted together with a high-static-pressure design. A listed input of 0.96 W is the notable efficiency-related parameter. Check procurement data comparison cooling specification. |
12 | 80×80×25 | 49.8 | 27.5 | 0.96 | 2500 | 22 | |
9G1212P4H04 | Sanyo Denki 12VDC 3.72W DC Axial Fan for UPS, server and telecom equipment cooling The 9G1212P4H04 is a Sanyo Denki 12 VDC, 119 × 119 × 25 mm DC axial fan for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. Base duty-point matching on the stated power demand. Check the full suffix before confirming connector details. Focus: procurement data comparison. |
12 | 119*119*25 | 147.6 | 64 | 3.72 | 2850 | 40 | |
![]() 9GA0924J4D03 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki configures 9GA0924J4D03 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 90 × 90 × 25 mm dimensions. The 90 × 90 × 25 mm format is the primary stated selection detail. For fan selection, start with the supplied supply requirement. Treat bearing and life data as suffix-specific. |
24 | 90*90*25 | - | - | - | - | - | |
![]() 9GA0412P3H01 | Sanyo Denki 12VDC 3.36W DC Axial Fan for UPS, server and telecom equipment cooling For thermal management in servers, UPS systems, and telecom equipment, the 9GA0412P3H01 provides a 12 VDC DC axial fan configuration measuring 40 × 40 × 28 mm. 14500 rpm is the model's most prominent operating value. The recorded static-pressure entry should guide enclosure sizing. Check the full suffix before confirming connector details. |
12 | 40*40*28 | 32 | 347 | 3.36 | 14500 | 50 | |
![]() 9S0924L4011 | Sanyo Denki 24VDC 0.96W DC Axial Fan for UPS, server and telecom equipment cooling For thermal management in servers, UPS systems, and telecom equipment, the 9S0924L4011 provides a 24 VDC DC axial fan configuration measuring 92×92×25 mm. A listed noise figure of 17 dB is the key differentiating parameter. The recorded operating point should guide maintenance preparation. Confirm control inputs against the complete ordering code. |
24 | 92×92×25 | 49.8 | 13.1 | 0.96 | 1750 | 17 | |
![]() 109R0624M402 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling The 60 × 60 × 25 mm Sanyo Denki 109R0624M402 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Base fan selection on the stated motor input. Validate mounting and wiring from the model drawing. Focus: procurement data comparison ventilation capacity. |
24 | 60*60*25 | 21.4 | 19.6 | - | 2600 | 20 | |
![]() 9GA1224P4G0011 | Sanyo Denki 24VDC 11.28W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki configures 9GA1224P4G0011 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 120×120×25 mm dimensions. 365 Pa maximum pressure is the most distinctive duty-point parameter. Use the documented suffix definition when planning replacement evaluation. Match the exact part number before approving a substitute. |
24 | 120×120×25 | 228 | 365 | 11.28 | 6400 | 57 | |
![]() 9A0824S4021 | Sanyo Denki 24VDC 2.4W DC Axial Fan for UPS, server and telecom equipment cooling The 80 × 80 × 25 mm Sanyo Denki 9A0824S4021 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. Use the documented cooling output when planning cabinet ventilation planning. Confirm control inputs against the complete ordering code. |
24 | 80*80*25 | 71.4 | 48.1 | 2.4 | 3400 | 34 | |
![]() 109044UL | Sanyo Denki 230VAC 9W AC Axial Fan for automation and control cabinet cooling The 80 × 80 × 42 mm Sanyo Denki 109044UL brings 230 VAC AC axial fan cooling to servers, UPS systems, and telecom equipment. Series options require suffix verification. For procurement comparison, start with the supplied motor input. Treat bearing and life data as suffix-specific. Focus: procurement data comparison thermal-duty record. |
230 | 80*80*42 | 59.3 | 35.4 | 9 | 3100 | 44 | |
![]() 9GV0624P1G031 | Sanyo Denki 24VDC 33.6W DC Axial Fan for automation and control cabinet cooling The 9GV0624P1G031 is a Sanyo Denki 24 VDC, 60 × 60 × 38 mm DC axial fan for industrial controls, power cabinets, and energy systems. High airflow is highlighted together with a high-static-pressure design. For thermal validation, start with the supplied volume-flow figure. Verify the exact bearing and signal options in the datasheet. |
24 | 60*60*38 | 142.8 | 752.3 | 33.6 | 16000 | 66 | |
![]() 109P0424J3013 | Sanyo Denki 24VDC 4.32W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki 109P0424J3013 is a 24 VDC DC axial fan in a 40 × 40 × 28 mm format for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. 12500 rpm is the model's most prominent operating value. Check procurement data comparison mounting size. Focus: procurement data comparison mounting size. |
24 | 40*40*28 | 28 | 210 | 4.32 | 12500 | 44 | |
![]() 109P0412B301 | Sanyo Denki 12VDC 3.36W DC Axial Fan for UPS, server and telecom equipment cooling For thermal management in servers, UPS systems, and telecom equipment, the 109P0412B301 provides a 12 VDC DC axial fan configuration measuring 40 × 40 × 28 mm. 10300 rpm is the model's most prominent operating value. Use the documented cooling output when planning controller selection. Treat bearing and life data as suffix-specific. |
12 | 40*40*28 | - | - | 3.36 | 10300 | 40 |
Choosing the right automation starts with the operating point rather than the model name. Define the airflow you actually need in CFM or m³/h and the static pressure the fan must overcome, then look for units whose performance curves pass through that point with a safety margin instead of sitting at the edge of the curve.
Pay attention to the electrical details early. DC fans typically run on 12/24/48 V and integrate easily with control boards, while AC fans suit 115/230 V fixed-speed installations. If the airflow must change with load, choose EC technology with PWM or analog control and, where monitoring matters, a tachometer output so the controller can detect fan failure.
Environment and compliance come next. Match the IP rating to dust and moisture exposure, prefer ball bearings wherever the fan runs hot, vertically or around the clock, and confirm certifications — UL, CE, RoHS — against your destination market. Setting the acoustic limit in dBA early prevents late-stage redesign when the first unit proves too loud.
Finally, compare candidates on total delivery risk, not only on price: confirm stock for the quantity you need, check the lead time for the next batch, and ask for datasheets and dimension drawings before committing. Our team cross-checks curves, dimensions and electrical data for you before quotation There are currently 1,140 items in this category ready to compare.
Automation appear in almost every sector where heat or stale air must be moved reliably. Typical environments include server rooms and data centers, refrigeration condensers and cold-store evaporators, HVAC air handling units, telecom cabinets, medical and laboratory equipment, welding and CNC machine enclosures, and renewable-energy power cabinets. In each of these settings the fan is a critical component: its failure stops production, damages stored goods or forces expensive emergency downtime.
One recurring scenario comes from control cabinet retrofits: the original fan is obsolete, the mounting hole pattern cannot change, and downtime is measured in hours. We match the old unit against current series by frame size, airflow and noise, propose the closest drop-in alternative, and ship with a datasheet that lets the electrician connect it without redesign.
For cold storage operators the pain is simple: a failed evaporator or condenser fan must be replaced now, not after a six-week import cycle. Matching blade diameter, speed and protection class against stocked equivalents lets us restore cooling capacity within days, which is why replacement supply has become a core part of this category for us.
Whether you are building new equipment or maintaining an installed base, the workflow is the same: send us the operating point and constraints, and we return a validated selection with datasheets, curves and a clear lead time.
Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.
Every unit is covered by the manufacturer's warranty against defects in materials and workmanship, and we support you through the whole claim process so you deal with one supplier instead of chasing a factory overseas. If a failure appears in service, send us the serial number, operating conditions and photos, and we will arrange the replacement or credit path agreed in the quotation.
Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.